• 400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS
  • 400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS
  • 400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS
  • 400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS
  • 400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS
  • 400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS

400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS

Phase: Single Phase
Type: On-line
Protection: Overvoltage
Application: Industry
Classification: Lighting/Power
Standby Time: Standard Machine
Customization:
Gold Member Since 2024

Suppliers with verified business licenses

Guangdong, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
to see all verified strength labels (20)

Basic Info.

Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Brand
Ensure
Rated Voltage
380VAC 3phase with Ground
Rated Frequency
40-70 Hz (50/60 Auto-Sense)
Voltage Regulation
220VAC (+/-1%)
Frequency Regulation
50/60Hz
Power Factor
0.7/0.8 (Optional) Standard 0.7
Voltage Distortion
Linear Load<3% Non-Linear Load<6%
Current Crest Ratio
3:1
Operation Temperature
0~40degree Centigrade
Transport Package
Carton, Export Type Packing or According to Your R
Specification
260X570X717
Origin
China
HS Code
8504402000

Product Description

Key attributes

Other attributes

Warranty
1 years

 

Place of Origin
Guangdong, China

 

Brand Name
ensure

 

Model Number
GX9335C 10-800KVA

 

Phase
Three Phase

 

Protection
Overvoltage

 

Weight
1400

 

Type
On-line

 

Application
INSTRUMENTATION

 

low voltage protection
overload protection

 

Rated input voltage
380/400/415VAC 3-phase 4-wire

 

Rated frequency
50/60HZ

 

Input voltage range
±25%

 

Input frequency range
45Hz~65Hz

 

Input soft start function
0-100% 5-300settable

 

Input power factor
>0.98(If harmonic filter is added)

 

Frequency
50/60Hz

 

Inverter output voltage
380/400/415VAC 3-phase 4-wire

 

Maximum Bypass capability
1000% for 100ms

 

Packaging and delivery

Packaging Details
Carton, export type packing or according to your requirement

 

Port
ShenZhen
 

Product descriptions from the supplier

 
 
 
 
 
Overview
 
 

400kva Online UPS Low Frequency Ups With Isoltion Transformer For Big IDC Center Online UPS
 

Technical Specificat
Model GX9335C
Rectifier Type 6p 12p 6p 12p 6p 12p 6p 12p 6p 12p
Rated Nominal 120KVA/108KW 160KVA/144KVA 200KVA/180KW 300KVA/270KW 400KVA/360KW
Rated input voltage 380/400/415VAC 3-phase 4-wire
Rated frequency 50/60HZ
Input parameters 
Input voltage range ±25%
Input frequency range 45Hz~65Hz
Input soft start function 0-100%   5-300settable
Input power factor >0.98(If harmonic filter is added)
Input harmonic current (THDi) ‹4.5%(If harmonic filter is added) 
Bypass 
Bypass voltage range -20%~+15%
Bypass frequency range 50/60HZ±10%
Output parameters 
Inverter output voltage 380/400/415VAC 3-phase 4-wire
Voltage stability ±1%(Steady status),±3%(Transient status)
Frequency 50/60Hz
   Mains power synchronization window ±5%
Actually measured frequency accuracy (internal clock) 50/60Hz±0.01Hz
Output power factor 0.9(Output 90kW per 100kVA)
Transient response time <5ms
Inverter overload capability At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s
  3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds
Short circuit current from inverter
Maximum Bypass capability 1000% for 100ms
  With 100% balanced load <1°
Phase shift
characteristic With 100% imbalance load <1°
  100% linear load <1%
Total harmonic
Distortion(THDv) 100% non-linear load <3%
System efficiency (full load) Up to 94% (inverter efficiency is up to 98%)
Rectifier output parameters
Charger output voltage stability 1%
DC ripple voltage ≤1%
Operating environment 
Operating temperature range 0~40°C
Storage temperature -25~70°C(Without battery)
Relative humidity 0~95% No condensation
Noise (1m) 58-68dB
Protection level IP20
Standard Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3
400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS400kVA Online UPS Low Frequency UPS with Isoltion Transformer for Big IDC Center Online UPS

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
6
Year of Establishment
2023-11-22