Parameter datasheet | |||||
PV Input data | WL-030KTL | WL-036KTL | WL-040KTL | WL-050KTL | WL-060KTL |
Max. DC power(W) | 45000 | 54000 | 60000 | 75000 | 90000 |
Max. DC Voltage(V) | 1100 | ||||
MPPT voltage range(V) | 200-1000 | ||||
MPPT full power voltage range(V) | 500-850 | ||||
Rated input voltage(V) | 620 | ||||
Start-up voltage(V) | 200 | ||||
Max input current(A) | 38×2 | 38×3 | 38×3 | 40×3 | 38×4 |
Max short current(A) | 48×2 | 48×3 | 48×3 | 48×3 | 48×4 |
No. of MPPT tracker/No. of PV string | 2/5 | 3/6 | 3/6 | 3/7 | 4/8 |
Input connector type | MC4 | ||||
AC output data | |||||
Max. Output power(VA) | 33000 | 39600 | 44000 | 55000 | 66000 |
Nominal output power(W) | 30000 | 36000 | 40000 | 50000 | 60000 |
Max. output current(A) | 48 | 60 | 65 | 80 | 96 |
Nominal output voltage(V) | 3P+N+PE/3P+PE 230/400 | ||||
Grid voltage range(V) | 260Vac-519Vac (according to local standard) | ||||
Nominal output frequency(Hz) | 50/60 | ||||
Grid frequency range(Hz) | 45-55Hz/55-66Hz(according to local standard) | ||||
Output power factor | 1 default (adjustable from 0.8 leading to 0.8 lagging) | ||||
Output current THD | <3% | ||||
Efficiency | |||||
Max. efficiency | 98.50% | 98.65% | 98.65% | 98.80% | 99.00% |
Euro efficiency | 98.10% | 98.20% | 98.25% | 98.45% | 98.50% |
Protection | |||||
PV reverse polarity protection | YES | ||||
PV insulation resistance detection | YES | ||||
AC short circuit protection | YES | ||||
AC over current protection | YES | ||||
AC over voltage protection | YES | ||||
Anti-islanding protection | YES | ||||
Residual current detection | YES | ||||
Over temperature protection | YES | ||||
Integrated switch | YES | ||||
Surge protection | Integrated(tyoe II) | ||||
Smart IV curve scanning | YES | ||||
Quick Arc fault circuit interuption | Optional | ||||
General data | |||||
Dimensions(W×H×D,mm) | 450×485×210 | 710×470×236 | |||
Weight(kg) | 26 | 44 | 51 | ||
Protetcion degree | IP65 | ||||
Enclosure material | Aluminum | ||||
Ambient temperature range(ºC) | -25 to 60 | ||||
Hummidity range | 0-100% | ||||
Cooling concept | Integrated fan | ||||
Topology | Transformerless | ||||
Operating altitude(m) | ≤4000 | ||||
Noise Emission(dB) | <51 | <55 | |||
Night power consumption(W) | <1 | ||||
Communication interface | RS485 / WiFi / Wire Ethernet / GPRS (optional) | ||||
Certification & standards | |||||
EMC standard | EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12 | ||||
Safety standard | IEC 60068, UL1741, EN62109 | ||||
Grid-connection | IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727 |