• 3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater
  • 3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater
  • 3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater
  • 3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater
  • 3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater
  • 3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater

3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater

Certification: CSA, SASO, RoHS, UL, CB, CCC, ISO9001, CE
Working Medium: R410A
Heat Source Type: Air Source Heat Pump
Cop: 3.91
Noise: 53 dB (a)
Transport Package: Carton
Samples:
US$ 560/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
KRS-50B/N2
Specification
5KW
Trademark
Kolant
Origin
Guangzhou, China
HS Code
8418612090

Product Description

Nowadays, due to the constant rise in oil and gas prices, there is an increasing need for energy efficient products that provide greater savings to users. Heat pumps offer a very efficient and cost-effective way to heat homes, replacing
boilers that use gas or other fossil fuels.
Most of homes use conventional and energy-inefficient systems such as gas boilers or furnace  in order to produce domestic hot water. 
Main advantages of using a heat pump compared to a boiler:
• Energy upgrading of buildings
• Energy efficiency and operating cost reductions up to 70%
• Return on investment approximately within 3 years

Main advantages of using a heat pump compared to a central solar field:
• Faster return of investment
• Less space required
• Less need for maintenance
• Smaller volume of hot water storage tanks and hence less space for boiler rooms
Solustions by Kolant DHP

• Specifically designed for heating applications Nominal capacity from 3.5kW to 9kW
• Maximum water temperature 60°C
• Guaranteed operation without the performance reduction nor the temperature of the produced water, for ambient temperatures up to 43°C
• Choice of anti-corrosion protection
• External heat source control
• Master-slave units factory-installed parallel operation
• Pro Dialog Plus controller with liquid crystal display
• Communication with MODBUS systems

3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water HeaterYour best choice for domestic hot water
Domestic hot water heat pumps from Kolant intend to provide the most environmental solution for the generation of
domestic hot water. By replacing the existed central hot water devices such as electric boilers, oil boilers etc, more
than 70% of the energy required for domestic hot water can be taken form renewable source instead of electricity
heating or fossil fuel burning. This almighty heat pump also can be used as an energy saving heating device in
many places, e.g as a second heat source of a solar heating system.

3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater

3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater

3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater3.5kw, 5kw, 7.2kw, 9kw Residential Domestic Air to Water Heat Pump Hot Water Heater
Model KRS-35B/N2 KRS-50B/N2 KRS-72B/N2 KRS-90B/N2-L
Power supply Ph-V-Hz 220V/1PH/50HZ 220V/1PH/50HZ 220V/1PH/50HZ 220V/1PH/50HZ
Working temp ºC -15ºC~43ºC -15ºC~43ºC -15ºC~43ºC -15ºC~43ºC
Max. outlet Water temp. ºC 60ºC 60ºC 60ºC 60ºC
Water Heating (A20/W55) Capacity KW 3.5 5 7.2 9
Hot water yield L/h 75 107 155 193.4651763
Input KW 0.9 1.28 1.79 2.31
COP W/W 3.89 3.91 4.02  
Rated current A 3.97 5.8 8.23 11.17
Hot water yield m3/h        
Max. input consumption KW 1.31 1.86 2.60 3.3
Max. input current A 6.2 8.9 12.4 16.02631579
Starting current A 18 28 35 61
set Temp. ºC 25~60 25~60 25~60  
Water system materials of water pipe   copper  copper  copper  copper 
water flow m3/h 0.8 1.1 1.5 1.934651763
Water different pressure Kpa 60 50 60 60
Diameter,water inlet pipe mm DN20 DN20 DN20 DN20
Diameter,water outlet pipe mm DN20 DN20 DN20 DN20
Design pressure  Mpa 4.2/0.02 4.2/0.02 4.2/0.02 4.2/0.02
Gas Weight (R410A) g        
Outdoor noise level  (1 meter) dB(A) 52 53 54 55
Outdoor unit Dimension(L*W*H) mm 750*264*493 935*282*545 1002*302*620 1002*350*620
Packing(L*W*H) mm       1075*380*650
NG/WG kg       73/87
Warranty For the Unit Month        
NOTE 1% free spare parts provided for maintenance(min order 20ft container, but mix less than 3 models, less than min order, no free spare parts provided).
Testing condition: ambient Dry/Wet Bulb Temp.: 20ºC/15ºC; Water Inlet/Outlet Temp.: 15ºC/55ºC.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
54
Year of Establishment
2009-11-16