• 230kv/72.5kv/15kv Outdoor Double Side Break Disconnector Switch
  • 230kv/72.5kv/15kv Outdoor Double Side Break Disconnector Switch
  • 230kv/72.5kv/15kv Outdoor Double Side Break Disconnector Switch
  • 230kv/72.5kv/15kv Outdoor Double Side Break Disconnector Switch
  • 230kv/72.5kv/15kv Outdoor Double Side Break Disconnector Switch

230kv/72.5kv/15kv Outdoor Double Side Break Disconnector Switch

Type: High-voltage
Structure: Three-column Disconnector
Installation: Outdoor High-voltage
Operation: Electric
Grounding Mode: Grounding
Movement Mode: Horizontal Rotary Type
Samples:
US$ 10000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
GW
Number of Poles
Three Pole
Grounding
Single Ground
Certification
ISO
Transport Package
Wooden
Specification
230KV
Trademark
HEMG
Origin
China
Production Capacity
50000

Product Description




230kv/72.5kv/15kv Outdoor Double Side Break Disconnector Switch
230kv/72.5kv/15kv Outdoor Double Side Break Disconnector Switch
230kv/72.5kv/15kv Outdoor Double Side Break Disconnector Switch
 
ÍTEM DESCRIPTION OF THE PARAMETER / FEATURE UNIT OF MEASUREMENT PARAMETER /
REQUESTED FEATURE
OFFERED PARAMETER /
REQUESTED FEATURE
OFFERED PARAMETER /
REQUESTED FEATURE
OFFERED
1 Nominal system voltage kV 230 230 69 69 13.8 13.8
2 Kind   3 columnas doble apertura lateral 3 columnas doble apertura lateral 3 columnas doble apertura lateral 3 columnas doble apertura lateral 2 columnas 2 columnas
3 Class   Intemperie Intemperie Intemperie Intemperie Intemperie Intemperie
4 Number of poles   3 3 3 3 3 3
5 Nominal design voltage kV 245 245 72.5 72.5 24 24
6 Dielectric rigidity to atmospheric impulses at sea level (main blades and grounding blades)              
6.1 a) On land and between poles kVp 1050 1050 325 325 125 125
6.2 b) Through the sectioning distance kVp 1200 1200 375 375 145 145
7 Dielectric rigidity at industrial frequency at sea level (main and grounding blades)              
7.1 a) On land and between poles kV 460 460 140 140 50 50
7.2 b) Through the sectioning distance kV 530 530 160 160 60 60
8 Minimum contour distance (Pollution level III) (*) mm 6125 6125 1813 1813 600 600
9 Nominal frecuency Hz 60 60 60 60 60 60
10 Normal nominal current A ≥2000 ≥2000 ≥2500 ≥2500 2000 2000
11 Rated short-term rated current, 1s kA ≥31,5 ≥31,5 ≥31,5 ≥31,5 ≥40 ≥40
12 Short circuit duration s 1 1 1 1 1 1
13 Maximum radio interference voltage µV < 2500 < 2500 - - - -
14 Insulators: Material   Porcelana Porcelana Porcelana Porcelana Porcelana Porcelana
15 Line terminal connectors for conductor AAC 1033.5 MCM   SI SI SI SI SI SI
16 Mechanical strength class   M2 M2 M2 M2 M2 M2
17 Nominal Transfer Current A ≥ 1600 ≥ 1600 ≥ 1600 ≥ 1600 - -
18 Rated Bar Transfer Voltage Vr.m.s. 200 200 100 100 - -
19 Main blades operating mechanism   Motor 125 VCC Motor 125 VCC Motor 125 VCC Motor 125 VCC MANUAL MANUAL
20 Galvanized steel structure is required: YES-NO   SI SI SI SI NO NO
               

Send your message to this supplier