Pattern: | Mini Load Cell |
---|---|
Transform Type: | Resistance Strain |
Out-Wire: | 4-Wire |
Output Signal Type: | Analog Type |
Feature: | Corrosion Resistant |
Production Process: | Normal Wirewound |
Customization: |
---|
Suppliers with verified business licenses
Specifications: |
||
capacity |
kg |
0.3,0.5,0.6,1,1.5,2,3,5,6 |
safe overload |
%FS |
120 |
ultimate overload |
%FS |
150 |
rated output |
mV/V |
1.0 ± 0.1 |
excitation voltage |
Vdc |
9~ 12 |
combined error |
%FS |
± 0.03 |
zero unbalance |
%FS |
± 2 |
non-linearity |
%FS |
± 0.02 |
hysteresis |
%FS |
± 0.02 |
repeatability |
%FS |
± 0.01 |
creep |
%FS/30min |
± 0.02 |
input resistance |
Ω |
405 ± 6 |
output resistance |
Ω |
350 ± 5 |
insulation resistance |
M Ω |
≥ 5000 @ 100 Vdc |
operating temperature range |
ºC |
-20 ~ +60 |
compensated temperature range |
ºC |
-10 ~ +40 |
temperature coefficient of SPAN |
%FS/10ºC |
± 0.02 |
temperature coefficient of ZERO |
%FS/10ºC |
± 0.03 |
Suppliers with verified business licenses