• 1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply
  • 1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply
  • 1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply
  • 1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply
  • 1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply
  • 1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply

1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply

Phase: Single Phase
Type: On-line
Protection: Unbalanced Loads
Application: Fire Safety
Classification: Lighting/Power
Standby Time: Long-acting Machine
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Zhejiang, China
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 30 days
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (25)

Basic Info.

Model NO.
UPS
Standby UPS
Sine Wave Output UPS
Output Capacity
Small Type
Equipment Mode
Decentralized
Brand
Xinsilu
Transport Package
Crate
Specification
282*145*220
Trademark
NICEA
Origin
China
HS Code
3101
Production Capacity
500pieces/Week

Product Description

7.Storage  and  maintenance
7-1.Storage

Please charge for 7 hours before storing this  it upright in a dry place
During storage,please perform charging maintenance according to the following  table:
Storage temperature Charging interval Charging time
-25°C-40°ºC Every 3 months 1 to 2 hours
40°ºC-45°ºC Every 2 months 1 to 2 hours
7-2.Maintenance
The UPS system uses dangerous voltage and can only be repaired by qualified   maintenance   personnel.
There  is  a  danger  of  electric  shock.Even  if  the  main  power  supply  is disconnected,the components in the  UPS system are still connected to the battery and are dangerous.
To perform any service or maintenance,you should disconnect the battery first and confirm that there is no dangerous voltage across the bus capacitor.
Only maintenance personnel who are fully familiar with batteries and have prepared protective measures can engage in or supervise battery replacement operations.Unauthorized personnel must stay away from the battery.
There is a risk of electric shock.The battery circuit is not isolated from the mains input.Dangerous voltage may appear between the battery terminal and the ground.Before touching,please make sure there is no voltage!
The battery may cause electric shock and generate short-circuit high current. Before repairing,please remove metal objects such as watches and rings,
and use tools with insulator handles and handles during repairs.
When replacing batteries,please install batteries of the same number and
specifications
Do not throw the battery into the fire,otherwise it may cause an explosion. Waste batteries should be disposed of in accordance with local regulations.
Do not disassemble or damage the battery.Once the electrolyte contained

Only replace fuses of the same type and amperage to avoid fire.
Non-professionals should not disassemble the UPS system.
6.Technical parameters
Model 6KVA 10KVA
Capacity 6000VA/5400W 10000VA/9000W
Input
Voltage
Range
Minimum switching voltage At 50%load,110VAC±3%;at 100%load,176VAC±3%
Minimum recovery voltage Minimum switching voltage +10V
Maximum switching voltage 300VAC±3%
Maximum recovery voltage Maximum switching voltage -10V
Frequency Range 40~60HZ@50HZ    system/50~70HZ@60HZ    system
Phase L+N+PE
Power Factor 100%load≥0.99
Output
Output Voltage 208/220/230/240VAC
Output Voltage Accuracy ±1%
Frequency Range
(synchronization range)
40~60hz@50HZsystem/50~70HZ@60HZsystem
Frequency Range(battery mode) 50hz±0.1HZor60HZ±0.1HZ

Overload
AC Mode 30min@102%~110%load,10min@110%~130%load
30s@130%~150%load,500ms@>150%load
Battery Mode 10min@102%~110%load,1min@110%~130%load
10s@130%~150%load,500ms@>150%load
Current peak ratio 3:1(Maximum)
Harmonic distortion ≤2%(linear load),≤5%(non-linear load)
Switching time Mains(→Battery 0ms
Inverter(-→Bypass 0ms
Effectiveness
AC Mode 95%
Battery Mode 94.8%(20pcs batteries)
Battery
Standard Battery Number 12-16 pCS                           16 pcs
Charging Current default 1A
Charging Voltage 13.65×N±1%
Long Run Battery Number 16~20 pcS
Charging Current Preset:6A±10%,1-12Aoptional
Charging Voltage 13.65×N±1%
Apperance
Standard Size
Long×Width×High(mm)
384x190×730
Long Run Size
Long×Width×High(mm)
384×190×335
Environment
Operating Temperature 0~40ºC
Operating Moisture <95%And no condensation
Operating Altitude <1000m**
Noise ess than 50dB@1Meter
Management
SmartRS-232 Support Windows@2000/2003/XP/Vista/2008,Windows@7/8,Linux,Unix and MAC
Optional SNMP Support for power management by SNMP administrator and web browser.

"When the output voltage is set to 208VAC,the output power will be reduced to 90%.
"If the  UPS  is  installed  and  used  in  an  environment  with  an  altitude  of  more  than  1000  meters,the output  power  should  be
calculated  to  decelerate  by   1%per  100  meters.
***Please  understand  that  there  will  be  no  notice  when  product  specifications  are  changed.

5-2.Warning Instruction
Warning: The UPS does  not enter the failure mode, and the LCD displays  an alarm
code
Warning Code Description
Warning Code English Meaning Linked Active Triggering Conditions Recovering
Conditions
1 Battery is not
connected
Warning
battery discharge
Battery voltage less than 8V/PCS Recoverable
(10V/PCS)

2
Low voltage in battery Warning, battery test models return to main model Default 11.2/pcs, Custom settings 10.5-14V/PCS(2) Recoverable(Action point +0.2V/pcs)

8

High voltage in battery
Warning
battery discharge
Default 11.2/pcs, Custom settings +0.4V/PCS Recoverable
(Default13.7V/PCS custom settings + 0.4V/pcs)

9
Chargerfailure
Warning
After 5 minutes of
charging, the battery  voltage is still less than 10V
Recoverable
battery voltage  more than 10.5V)

10
Over-temperature
warning
Warning,
battery discharge
PFC or INV temperature sensor is higher than 80 degrees Celsius Recoverable
(The temperature  sensor is below 75 degrees Celsius)
12 Fan failure Warning No fan speed signal detected Recoverable

13

Mains disconnec

Warning
The difference between the mains voltage and  the bypass voltage is  greater than 100V
Recoverable
14 EEPROM failure Warning EEPROM read and write failed Unrecoverable
18 Inverter output
overvoltage
Warning,
battery discharge
load more than 102% Recoverable
(overload less than 97%)
23 EPO action Warning,
battery discharge
  Recoverable
24 Maintenance switch action Warning Short circuit of CN4
terminal on control board
Recoverable
The  pictures     or  diagrams       involved     in  this    manual    are   for  reference       only  . Please      refer    to  the   actual
product    in the  end  . Specifions      are   subject    to  change    without   notice.

5.Faults and warning instructions
5.1 Description of the fault
Fault: The UPS enters Fault mode and the LCD displays the fault code.
The fault code table

1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply
1kVA, 2kVA, 3kVA, 4kVA, 5kVA, 6kVA, 7kVA, 8kVA, 9kVA, and 10kVA Line UPS with Battery Uninterruptible Power Supply

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
12
Year of Establishment
2014-03-14