• 1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine
  • 1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine
  • 1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine
  • 1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine
  • 1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine
  • 1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine

1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine

After-sales Service: Yes
Warranty: 2 Years
Output Type: DC
Number of Blade: Three Blade
Rotating Shaft: Horizontal
Stress Way of Blade: Resistance
Samples:
US$ 280/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
  • Our Advantages
  • More products
  • Case
Overview

Basic Info.

Model NO.
FKJ-B 2KW48V
Power
>100kW
Phase
3
Certification
CE, ISO
Wind Turbine Rated Power
2kw
Wind Turbine Max. Power
4kw
Solar Panel Power
1kw
Display Mode
LCD
Communication Interface
RS485,WiFi,Grps,RJ45
Cetificate
CE/ISO9001
Efficiency
More Than 92%
Dump Load
Included
Transport Package
Wooden Case
Specification
560*430*320mm/20kg
Trademark
Deming
Origin
Shandong
HS Code
8543709990
Production Capacity
50000 PCS/Year

Product Description

 

Product Description

1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine
Off-Grid PWM Wind Solar (
disel) Hybrid Controller  

FKJ-B model off grid PWM wind solar hybrid controller Product Characteristics

1. The product is manufactured according the JB/T6939.1-2004 industrial standard and GB/T19115.1-2003 national standard also with users' technical requirements.

2. Big LCD display.The images tell working state visually.Various data show: real-time wind turbine voltage,current,power;solar panel voltage,current,power;battery group voltage, charge current.

3. Two sets of control systems:PWM constant voltage system and three-phase dump load system.

4. When the strong or super-strong wind conditions PWM control to ensure battery charged by the wind turbine with constant voltage and current.

5. When the battery disconnect or damage, the three-phase dump load will start automatically to avoid the wind turbine idling and runaway accident.

6. The protection function of battery: polarity reverse protection, disconnection and damage protection.

7. Over-charging protection of the battery: When the battery is full, the three-phase dump load will work, the wind turbine will brake and stop charge the battery.

8. Auto recharging of battery: When the battery voltage reduces to 108% of the rated voltage,it stops three-phase dump load to recharge battery automatically.

9. The controller is equipped with manual brake switch. To using this switch, the wind turbine will carry out three-phase dump load forcibly.

10. The inside of the controller is equipped with surge arrester. Contain the over voltage into the wind turbine under the bearable voltage of the equipment or system. On the other way, to conduct the strong lightening current into the earth directly to avoid any damage of equipment.

* Solar panel control system is optional.Based on customers' requirement.

* Disel generator port is optional.Control the generator start and stop automatically

* Adopt Modbus Communication protocol. Convenient to carry out the secondary development.

* Adjusting the technical specification via RS485 is available.Convenient to adjust the different wind turbines for professional customers.

* Support WIFI and GPRS.Customers can monitor the real-time working state of the on grid wind power system via PC and mobile and query history working sate.Both Android and OS are compatible in Mobile.

* For the different wind turbine, the controller can be equipped with mechanical yawing, Rotate tail control, furled empennage, mechanical brake,hydraulic brake, electromagnetism brake and other brake functions.

 

Detailed Images

Detailed Photos

1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine
1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine
1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine
1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine
1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine

Product Parameters


Technical parameters of off grid wind solar (diesel) hybrid controller 1KW

Type 1KW12V 1KW-24Vdc 1KW-48Vdc
Wind turbine rated power 1KW 1KW 1KW
Wind turbine max. power 2KW 2KW 2KW
*Solar panel power 300Wp 300Wp 300Wp
Battery 12Vdc 24Vdc 48Vdc
Function Rectifier,charge, control, *DC output
Automatic protection function Over voltage protection, constant voltage charge, arrester
Manual function Manual brake
Display mode LCD+LED
Display content Wind turbine voltage, current, power; solar panel voltage, current, power; battery voltage, charge current
PWM constant pressure voltage >14Vdc >29Vdc >58Vdc
Wind turbine 3-phase dump load voltage 15±1Vdc 30±1Vdc 60±1Vdc
Wind turbine recharge voltage 13.5±1Vdc 27±1Vdc 54±1Vdc
* Solar control stop charging voltage 15±1Vdc 29±1Vdc 58±1Vdc
*Solar control recharge voltage <14Vdc <29Vdc <58Vdc
*Diesel generator starting voltage 10±1Vdc 20±1Vdc 40±1Vdc
*Diesel generator off voltage 13.5±1Vdc 27±1Vdc 54±1Vdc
Self-provided battery connecting wire >16 mm² >8mm² >6mm²
PWM fuse 100A 50A 25A
* Solar fuse 32A 16A 10A
Charging fuse 125A 63A 40A
Work environment temperature -30-60°C
Relative humidity <90% No condensation
Noise (1m) <40dB
Degree of protection IP20(Indoor)IP65 (Outdoors)
Cooling method Forced air cooling
* Extral Control function (optional) Yawing, variable pitch, mechanical brake, hydraulic brake, electromagnetism brake
* Communication interface (optional) RS485/USB/GPRS/WIFI/Ethernet
*Temperature compensation (optional) -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C
Controller Size (mm)  Weight (kg) 510*360*240   17 Kg 510*360*240   17 Kg 510*360*240   17 Kg
Dump load Size (mm)  Weight (kg) 290*250*120    5 Kg 290*250*120    5 Kg 290*250*120    5 Kg

*Above parameter only for reference. Could be custom made to user specifications. 
Technical parameters of off grid wind solar (diesel) hybrid controller 2KW

Type 2KW-24Vdc 2KW-48Vdc 2KW-96Vdc
Wind turbine rated power 2KW 2KW 2KW
Wind turbine max. power 4KW 4KW 4KW
*Solar panel power 600Wp 600Wp 600Wp
Battery 24Vdc 48Vdc 96Vdc
Function Rectifier,charge, control, *DC output
Automatic protection function Over voltage protection, constant voltage charge, arrester
Manual function Manual brake
Display mode LCD+LED
Display content Wind turbine voltage, current, power; solar panel voltage, current, power; battery voltage, charge current
PWM constant pressure voltage >29Vdc >58Vdc >116Vdc
Wind turbine 3-phase dump load voltage 30±1Vdc 60±1Vdc 120±2Vdc
Wind turbine recharge voltage 27±1Vdc 54±1Vdc 108±2Vdc
*Solar control stop charging voltage 29±1Vdc 58±1Vdc 116±2Vdc
*Solar control recharge voltage <29Vdc <58Vdc <116Vdc
*Diesel generator starting voltage 20±1Vdc 40±1Vdc 80±2Vdc
*Diesel generator off voltage 27±1Vdc 54±1Vdc 108±2Vdc
Self-provided battery connecting wire >20mm² >10mm² >24mm²
PWM fuse 100A 50A 32A
*Solar fuse 32A 16A 10A
Charging fuse 125A 63A 40A
Work environment temperature -30-60°C
Relative humidity <90% No condensation
Noise (1m) <40dB
Degree of protection IP20(Indoor)IP65 ( Outdoors )
Cooling method Forced air cooling
*Extral Control function (optional) Yawing, variable pitch, mechanical brake, hydraulic brake, electromagnetism brake
* Communication interface (optional) RS485/USB/GPRS/WIFI/Ethernet
*Temperature compensation (optional) -4mv/°C/2V,-35°C~+80°C, Accuracy:±1°C
Controller Size (mm)  Weight (kg) 580*400*240    22 Kg 510*360*240    17 Kg 510*360*240    17 Kg
Dump load Size (mm)  Weight (kg) 410*290*120     8 Kg 410*290*120     8 Kg 410*290*120     8 Kg

*Above parameter only for reference. Could be custom made to user specifications.  


Technical parameters of off grid wind solar (diesel) hybrid controller 5KW

Type 5KW-48Vdc 5KW-96Vdc 5KW-240Vdc
Wind turbine rated power 3KW 3KW 3KW
Wind turbine max. power 6KW 6KW 6KW
* Solar panel power 2KWp 2KWp 2KWp
Battery 48Vdc 96Vdc 240Vdc
Function  Rectifier,charge, control, *DC output
Automatic protection function Over voltage protection, constant voltage charge, arrester
Manual function Manual brake
Display mode LCD+LED
Display content Wind turbine voltage, current, power; solar panel voltage, current, power; battery voltage, charge current
PWM constant pressure voltage >58Vdc >112Vdc >290 Vdc
Wind turbine 3-phase dump load voltage 60±1Vdc 120±2Vdc 300±5Vdc
Wind turbine recharge voltage 54±1Vdc 108±2Vdc 280±5Vdc
*Solar control stop charging voltage 60±1Vdc 120±2Vdc 300±5Vdc
*Solar control recharge voltage 54±1Vdc 112±2Vdc 280±5Vdc
*Diesel generator starting voltage 40±1Vdc 80±2Vdc 200±5Vdc
*Diesel generator off voltage 54±1Vdc 108±2Vdc 270±5Vdc
Self-provided battery connecting wire >20mm² >10mm² >6mm²
PWM fuse 125A 80A 32A
*Solar fuse 40A 80A 10A
Charging fuse 160A 100A 40A
Work environment temperature -30-60°C
Relative humidity <90% No condensation
Noise (1m) <40dB
Degree of protection IP20(Indoor)IP65 (Outdoors)
Cooling method Forced air cooling
*Extral Control function (optional)  Yawing, variable pitch, mechanical brake, hydraulic brake, electromagnetism brake
*Communication interface (optional) RS485/USB/GPRS/WIFI/Ethernet
*Temperature compensation (optional) -4mv/°C/2V,-35°C~+80°C,Accuracy:±1°C
 Controller Size (mm)  Weight (kg) 580*400*240     23Kg 510*360*240      17Kg 510*360*240     17Kg
Dump load Size (mm)  Weight (kg) 600*450*380     28Kg 600*450*380      28Kg 600*450*380     28Kg

*Above parameter only for reference. Could be custom made to user specifications. 
 

*ATechnical pameters of grid wind solar (diesel) hybrid controller 2KW

Type

2KW-24Vdc

2KW-48Vdc

2KW-96Vdc

Wind turbine rated power

2KW

2KW

2KW

Wind turbine max. power

4KW

4KW

4KW

*Solar panel power

600Wp

600Wp

600Wp

Battery

24Vdc

48Vdc

96Vdc

Function

Rectifier, charge, control, *DC output

Automatic protection function

Over voltage protection, constant voltage charge, arrester

Manual function

Manual brake

Display mode

LCD+LED

Display content

Wind turbine voltage, current, power; solar panel voltage, current, power; battery voltage, charge current

PWM constant pressure voltage

>29Vdc

>58Vdc

>116Vdc

Wind turbine 3-phase dump load voltage

30±1Vdc

60±1Vdc

120±2Vdc

Wind turbine recharge voltage

27±1Vdc

54±1Vdc

108±2Vdc

*Solar control stop charging voltage

29±1Vdc

58±1Vdc

116±2Vdc

*Solar control recharge voltage

<29Vdc

<58Vdc

<116Vdc

*Diesel generator starting voltage

20±1Vdc

40±1Vdc

80±2Vdc

*Diesel generator off voltage

27±1Vdc

54±1Vdc

108±2Vdc

Self-provided battery connecting wire

>20mm²

>10mm²

>24mm²

PWM fuse

100A

50A

32A

*Solar fuse

32A

16A

10A

Charging fuse

125A

63A

40A

Work environment temperature

-30-60°C

Relative humidity

<90% No condensation

Noise (1m)

<40dB

Degree of protection

IP20(Indoor)IP65 ( Outdoors )

Cooling method

Forced air cooling

*Extral Control function (optional)

Yawing, variable pitch, mechanical brake,

hydraulic brake, electromagnetism brake

* Communication interface (optional)

RS485/USB/GPRS/WIFI/Ethernet

*Temperature compensation (optional)

-4mv/°C/2V,-35°C~+80°C, Accuracy:±1°C

Controller Size (mm)  Weight (kg)

580*400*240    22 Kg

510*360*240    17 Kg

510*360*240    17 Kg

Dump load Size (mm)  Weight (kg)

410*290*120     8 Kg

410*290*120     8 Kg

410*290*120     8 Kg

*Above parameter only for reference. Could be custom made to user specifications. 

Certifications

1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine

Company Profile

1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine

Our Advantages

1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine

More products

1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine

Case

1.5kw 2kw 2.5kw 24V 48V Wind Power Controller Wind Generator Charge Controller for Wind Turbine


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
55
Year of Establishment
2004-03-22