• Wimshurft Machine Induction Generator/ Physics Instruments Teaching Equipment
  • Wimshurft Machine Induction Generator/ Physics Instruments Teaching Equipment
  • Wimshurft Machine Induction Generator/ Physics Instruments Teaching Equipment
  • Wimshurft Machine Induction Generator/ Physics Instruments Teaching Equipment
  • Wimshurft Machine Induction Generator/ Physics Instruments Teaching Equipment
  • Wimshurft Machine Induction Generator/ Physics Instruments Teaching Equipment

Wimshurft Machine Induction Generator/ Physics Instruments Teaching Equipment

Condition: New
Customized: Customized
Certification: ISO9001
Material: PVC
Type: Teaching Instrument
Base: Plastic Base
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Zhejiang, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (27)

Basic Info.

Model NO.
23008
Electrophorus
Plexiglass Material, φ275mm, 3mm Thick
Certificate
ISO9001
Crank Speed
120 R/Pm
Spark Discharge Distance
Not Less Than 55mm
Transport Package
Carton Box
Specification
300x188x330mm
Trademark
SHUN MA
Origin
Yuyao Zhejiang China
HS Code
9023000000
Production Capacity
200000 PCS /Year

Product Description

Wimshurst Static Electricity Generator


Product Introduction
The wimshurst static electricity generator is used to obtain a large amount of charge and high voltage (about tens of thousands of volts) in electrostatic experiments, and cooperate with other instruments to carry out experiments on charge distribution on the surface of conductors, power lines of electrostatic field, tip discharge and discharge of vacuum tubes. It can also do a series of experiments, such as electrostatic induction, spark discharge, tip discharge, and the change of capacitance of capacitors (referring to the Leiden bottle on the motor), etc.

Product Specification
 
Product name Wimshurst Static Electricity Generator
In an environment with a temperature of 20°C and a relative humidity of 65% crank speed 120 r/pm
Spark discharge distance not less than 55mm
Under the condition that the temperature is in the range of 5 to 30 °C and the relative humidity is less than 80% Spark discharge distance not less than 30mm
Electrophorus Plexiglass material, φ275mm, 3mm thick
Material Plastic
Size 300x188x330mm
 
  1. There is no beam and cantilever structure between the two electric combs of the generator.
2. The base is made of plastic with excellent insulating properties or other equivalent materials.
3. The radial runout of the electrification disc shall not exceed 1.5mm.
4. The unevenness of the two disks should be such that the distance between any point on the inner side of the two disks during the rotation of the generator disk is not less than 2.5mm, and the maximum is not more than 5.5mm.
5. The lateral movement of the central axis of the electrification plate is not more than 1mm. The lateral movement of the hand crank shaft is not more than 2mm.
6. The rotation of the starting plate should be smooth and flexible, and the instrument should not vibrate under the condition that the rotation speed of the hand crank is not more than 120 rpm.
7. The brushes are in good contact with the foil on the starter plate.
8. Electric combs are made of needle-like metal rods or camouflage-like bare copper wires.
9. The aluminum sheet on the starter panel is firmly inserted with plastic rivets.
 
  1. The coating height of Leyden bottle electrode plate shall not be less than 120mm, and the coating shall be firm without scratch or local falling off.

Electrification principle
The starter motor is an instrument that uses induction to energize. When two starter discs rotate rapidly, the charged system, especially the ball of the discharge fork equipped with an insulating handle, accumulates a large number of charges of different electrical properties respectively.

Product feature and application
The conductive layer in the conductive plate of this machine adopts high-quality aluminum foil, which has good conductivity and long service life, and can improve the electrification performance. It can be energized in wet weather and rainy days.

Maintenance and precautions
1. The starter plate should be placed in a dry and clean place.
2. Lubricating oil should be added to the rotating shaft of the starter plate frequently to ensure flexible rotation and reduce wear. After use, still cover the plastic bag to prevent dust from entering the instrument.
3. The conductive plate and the conductive layer in the Leiden bottle must not be bumped, scratched, wet or damp.
4. The machine must not be baked with an open flame.
5. The generator can not be powered, and the fault can be eliminated according to the relevant items in the troubleshooting.
Wimshurft Machine Induction Generator/ Physics Instruments Teaching EquipmentWimshurft Machine Induction Generator/ Physics Instruments Teaching EquipmentWimshurft Machine Induction Generator/ Physics Instruments Teaching EquipmentWimshurft Machine Induction Generator/ Physics Instruments Teaching Equipment
Wimshurft Machine Induction Generator/ Physics Instruments Teaching Equipment

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
195
Year of Establishment
2001-10-30