• Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum
  • Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum
  • Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum
  • Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum
  • Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum
  • Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum

Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum

Application: Construction, Overhead, Underground, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Customization:

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Packaging & Shipping
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
JKLYJ JKLGYJ 1KV 10kv 35kv
Wire Core Material
Aluminum Core
Certification
ISO, CCC, CE, RoHS, VDE
Model
Jklyj
Transport Package
Wooden Drum
Specification
Aluminum core
Origin
China
Production Capacity
50000m/Month

Product Description

Product Description

JKLYJ 10kV 1×150  Aluminum core XLPE insulated overhead cable.subways, high-rise buildings, shopping malls, schools, residences and other occasions that require high flame retardant properties of wires and environmental protection of the surrounding environment.
Standards
The products can be produced in accordance with GB, IEC, BS, and other standards.

Basic Information
The rated voltages are 0.6/1KV, 10KV and 35KV respectively. The cable laying temperature should not be lower than -20ºC. The basic maximum temperature of the cable during short circuit (the longest duration does not exceed 5S): XLPE insulation 250ºC. HDPE insulation 150ºC. PVC insulated 160c The maximum long-term allowable working temperature of overhead cable conductors: PVC insulation does not exceed 70 ºC. Polyethylene insulation should not exceed 70ºC; XLPE insulation should not exceed 9oºC. The allowable bending radius of overhead cables: single-core cables should not be less than 15 times the outer diameter of the cable, and multi-core cables should not be less than 10 times the outer diameter of the cable.
Application
When laying the cable, the ambient temperature should not be lower than -20ºC, and when laying below -20ºC, the cable must be preheated.
When laying overhead cables, the bending radius of the rated voltage 1KV overhead insulated cable should not be less than 6 times the outer diameter of the cable, and the 101KV and 35KV overhead insulated cables should not be less than 15 times the outer diameter. The cable erection method is the same as the bare overhead line, and still needs to be fixed on the insulator of the cross arm, but the distance can be appropriately reduced.
The cables should be used in conjunction with specially designed overhead insulated cable metal utensils.
During the laying and storage process, attention should be paid to the sealing of the cable end to prevent the cable from entering water and reducing its performance.

Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable AluminumWholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum

 
Product Parameters

 

0.6/1kVSingle core XLPE insulated PE sheathed power cable 
core 
×
cross
secticn
(mm2 )
Nominal
insulation
thickness
(mm)
Hickness
of
steel
tape
(mm)
Tickness
of
steel
Wire
(mm)
Nom.Sheath
Thickness
(mm)
Dia.of  Cable
(By calculation)
(mm)
Cable Weight
(Appr ox)
(kg/km)
Max.D.C.
Rasistance of
Conductor at
20ºC
(Ω/km)
YJV
YJLV
YJV22
YJLV22
YJV32
YJLV32
YJV
YJLV
YJV22
YJLV22
YJV32
YJLV32
YJV YJLV YJV22 YJLV22 YJV32 YJLV32 Cu Al
1x1.5 0.7 - - 1.4 - - 6 - - 44 - - - - - 121 -
1x2.5 0.7 - - 1.5 - - 6 - - 57 41 - - - - 741 12.1
1x4 0.7 - - 1.4 - - 7 - - 74 49 - - - - 4.61 7.41
1×6 0.7 - - 1.4 - - 7 - - 96 59 - - - - 3.08 4.61
1x10 0.7 - - 1.4 - - 8 - - 141 80 - - - - 183 3.08
1x16 0.7 0.2 0.8 1.4 1.8 1.8 9 13 13 203 105 311 213 393 296 115 1.91
1x25 0.9 0.2 0.8 1.4 1.8 1.8 11 14 15 300 147 425 272 521 368 0.727 1.2
1x35 0.9 0.2 1.25 1.4 1.8 1.8 12 15 17 397 184 532 318 749 535 0.524 0.868
1x50 1 0.2 1.25 1.4 1.8 1.8 13 17 18 532 236 681 386 929 633 0.387 0.641
1x70 1.1 0.2 1.25 1.4 1.8 1.8 15 19 20 734 314 904 483 1188 767 0.288 0.443
1x95 1.1 0.2 1.25 1.5 1.8 1.8 17 20 22 988 406 1170 588 1482 900 0.193 0.32
1x120 1.2 0.2 1.6 1.5 1.8 1.8 19 22 24 1232 498 1425 692 1896 1163 0.153 0.253
1x150 1.4 0.2 1.6 1.6 1.8 1.8 21 24 26 1519 609 1724 814 2248 1339 0.124 0.206
1x185 1.6 0.2 1.6 1.6 1.8 1.8 23 26 28 1880 747 2096 963 2659 1526 0.0991 0.164
1x240 1.7 0.2 1.6 1.7 1.8 1.9 26 28 31 2437 951 2670 1184 3306 1821| 0.0754 0.125
1x300 1.8 0.2 1.6 1.8 1.9 2 28 31 34 3022 1162 3277 1417 3981 2121 0.0601 0.100 
1x400 2.0  0.2 2.0  1.9 2 2.1 32 35 38 3872 1477 4158 1762 5206 2810| 0.047 0.0778
1x500 2.2 0.5 2.0  2.0  2.2 2.3 35 40 42 4920 1856 5647 2583 6446 3382 0.0366 0.0605
1x630 2.4 0.5 2.5 2.2 2.3 2.4 40 44 48 6306 2351 7166 3161 8431 4475 0.0283 0.0469
1×800 2.6 0.5 2.5 2.3 2.5 2.6 44 49 52 8008 - 8906 - 10352 - 0.0221 -
0.6/1kV3+1 XLPE insulated PVC sheathed power cable
core 
×
cross
secticn
(mm2 )
Nominal
insulation
thickness
(mm)
Hickness
of
steel
tape
(mm)
Tickness
of
steel
Wire
(mm)
Nom.Sheath
Thickness
(mm)
Dia.of  Cable
(By calculation)
(mm)
Cable Weight
(Appr ox)
(kg/km)
Max.D.C.
Rasistance of
Conductor at
20ºC
(Ω/km)
YJV
YJLV
YJV22
YJLV22
YJV32
YJLV32
YJV
YJLV
YJV22
YJLV22
YJV32
YJLV32
YJV YJLV YJV22 YJLV22 YJV32 YJLV32 Cu Al
3×1.5+
1×1.0
0.7 0.2 0.8 1.8 1.8 1.8 11 14 14 148 - 243 - 336 - 12.1 -
0.7 18.1 -
3×4+
1×2.5
0.7 0.2 1.25 1.8 1.8 1.8 13 15 17 255 165 365 276 591 501 4.61 7.41
0.7 7.41 12.1
3×10+
1×6
0.7 0.2 1.25 1.8 1.8 1.8 17 19 21 498 277 638 417 928 708 1.83 3.08
0.7 3.08 4.61
3×25
+1×16
0.9 0.2 1.6 1.8 1.8 1.8 23 25 28 1097 539 1285 726 1847 1289 0.727 1.2
0.7 1.15 1.91
3×50+
1×25
1.0 0.2 1.6 1.8 1.9 2.0  28 31 34 1910 867 2150 1107 2852 1809 0.387 0.641
0.9 0.727 1.2
3×95+
1×50
1.1 0.5 2 2.1 2.2 2.3 37 42 44 3579 1530 4316 2267 5139 3090 0.193 0.32
1.0 0.387 0.641
3×150+
1×70
1.4 0.5 2.5 2.3 2.5 2.6 45 50 53 5442 2283 6326 3167 7801 4642 0.124 0.206
1.1 0.263 0.443
3×240+
1×120
1.7 0.5 .2.5 2.7 2.8 2.9 56 61 65 8338 3633 9949 4745 11767 6563 0.0754 0.125
1.2 0.153 0.253
3×300+
1×150
1.8 0.5 2.5 2.9 3.0  3.1 65 67 70 10964 4457 12185 5678 14155 7848 0.0601 0.100 
1.4 0.124 0.206
3×400+
1×185
2.0 0.5 3.15 3.1 3.3 3.4 70 75 79 13997 5655 15362 7021 18463 10122 0.047 0.0778
1.6 0.0991 0.164
3×500+
1×240
2.2 0.5 3.15 3.4 3.5 3.6 78 93 88 17850 7145 19371 8665 22859 12153 0.0366 0.0605
1.7 0.0754 0.125
  
Company Profile


Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable AluminumWholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum

Packaging & Shipping

Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum

Certifications

Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable AluminumWholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum
Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable AluminumWholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable AluminumWholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum
Exhibition
Wholesale Customized Electric Cable Conductor Aluminum Conductor Wires Power Cable Aluminum

FAQ
1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first begining to the last. 

Welcome to visit us. We'll pick you up in Shenzhen.
 

2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.

 

3. What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy. 
You'd better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.

 

4. Can I get a discount?
It depends on your quantity, We can make a discount and afford the freight. Pls kindly contact us.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
3000000 RMB
Plant Area
501~1000 square meters