• Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine
  • Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine
  • Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine
  • Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine
  • Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine
  • Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine

Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine

Classification: Biological Diagnostics
Type: Biochemistry Analyzer
Certification: CE, ISO13485
Group: Middle-aged and Old
Name1: Chemistry Analyzer
Reagent Volume: R1:150~300UL, R2:20~150UL
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
HP-CHEM300H
Cuvette
Optical Length 5mm
Model No
HP-Chem300h
Throughput
400 Test Per Hour
Sample Volume:2UL-70UL(0.1UL Stepping)
2UL-70UL(0.1UL Stepping)
Linear Range
0.000-2.500ABS
Gross Weight
239kg
Mixing System
2 Independent Mixers
Absorbance Range
0~4.0ABS(10mm Conversion)
Transport Package
Wooden Package
Specification
ISO9001: 2008 ISO13485 CE SGS
Trademark
hepobio
Origin
China
HS Code
9027809900
Production Capacity
3500 PCS/Month

Product Description

Automatic Chemistry AnalyzerHP-CHEM300H   

Enhanced Liquid System
1.Precise sample and reagent aspiration
2.Built in bubble elimination prior to washing
3.High pressure interior probe wash
4.Carry-over<0.05%
Economy Usage
1.Light-spot Flatting Technology facilitates lower reaction volume
2.24 hour non-stop refrigeration at 4-10ºC
3.Minimum sample volume:2ul
4.Reagent volume:20-25ul
5.Minimum cuvette volume:150ul
Easy to perform maintenance
1.Front loaded reagent compartment for easier access
2.Easy access for routine maintenance and troubleshooting
3.Easy to connect pipeline and cable
User-friendly Interface
1.Real-time analytical and carousel status monitoring
Real-time QC Status Monitoring
1.Levy-Jennings chart and Twin-plot chart
2.QC Out-of-Range real-time alarm
Traceable Test Results
1.Historic date recall from reagent/calibrator/control archive
2.Intuitive software,easy historical results
Reflex function
1.User-defined customizable reflexive assays
2.Multiple reflexive criteria may apply to a single assay
3.A single reflexive criteria may apply up to 20 assays
Technical Specifications
System Function
Fully automated,discrete,random access,STAT,urine and homogeneous immunoassays,STAT sample priority
Throughput Constant 300 tests/hour,Massuring principles:Absorbance Photometry,Turbidometry
Methodology End-point,Fixed-time,Kinetic,Single/uual/Triple/Quadruple reagent chemistries,Monochromatic/Bichromatic
Programming User defined profiles and calculation chemistries
 
Sample Handling
Sample tray 120 positions for sample primary or secondary tubes and sample cups
Sample volume 2~100ul,step by 0.1ul
Sample probe Liquid level detection,clot detection and collision protection
Probe cleaning Interior and exterior automatic probe washing carry-over<0.05%
 
Reagent Handling
Reagent tray 80 positions in refrigerated compartment (4~10ºC)
Reagent volume R1:150~300ul,R2:20~150ul
Reagent probe Liquid level detection, collision protection and inventory check
Probe cleaning Interior and exterior automatic probe washing 
 
Reaction System
Reagent rotor Rotating tray,81 cuvettes with automatic washing
Cuvette Optical length 5mm
Reaction volume 150~450ul
Operating temperature  37ºC
Temperature fluctuation ±0.1ºC
Mixing system 2 independent mixers
 
Optical System
Light Source Halogen-tungsten lamp
Photometer           Reversed optics photometry 
Wavelength 340nm 405nm 450nm 510nm 546nm 578nm 630nm 670nm
Absorbance range 0~4.0Abs(10mm conversion)
Resolution  0.0001Abs
 
Control and Calibration
Calibration mode  Linear(one-point,two-point and multi-point),Logit-Log 5p,Spline,Factor 
 
Operation Unit
Operation system Windows XP SP2 or SP3/ Windows 7 Home Basic
Interface  RS-232
Working Conditions
Power Supply 200~240V 50/60HZ 1000W or 100~120V 60HZ 1000W
Temperature 15~30ºC
Humidity  35~85%
Water consumption 18L/hour,De-ionized water
Dimension  912mm*721mm*570mm(W*D*H)
 
 
 
HP-CHEM300H
Automatic Chemistry Analyzer
Specifications
Analyze Unit
Throughput Constant 3000T/h (non-ISE)
Theory Absorption spectrometry, transmission turbidimetry
Methodology End-point \Fixed-time\Kinetic\Ion selective electrode
Test according set up, random access
Reaction plate Contain 120 reaction cuvettes
Maximum reaction time 15 minutes
Minimum reaction volume 150 ul
Material of cuvettes Special UV-transparent optical glass
Cuvettes use Automatically cuvettes washing
Optical Unit
Light Source Halogen-tungsten lamp
Photometer Reversed optics
Wavelength 340nm-670nm wavelength option
Absorption 0-4.0 Abs(10mn conversion)
Reagent Unit
Reagent plate 80 reagent positions ,support for single and double reagent, reagent completely open
Reagent storage temperature 4~10 degree
Reagent bottle 15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 ml
Reagent volume R1:150-300 ul,R2:20-150ul  step by 1.0 ul
Reagent/Sample Probe Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.
Sample Unit
Sample plate 120 sample positions
Sample type Human (animal) serum \plasma\urine etc.
Samples cup Support one-off micro cups
Sample volume 2-100 ul, step by 0.1 ul
Sample/reagent probe Automatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.
Temperature control Unit
Heating method Direct thermal solid thermostat closed
Temperature equilibrium time <3 minutes
Reaction temperature 37 ±0.1 degree
Temperature fluctuation ±0.1 degree
 
Operation Unit
Software WindowsXP \2000
Database SQL Server
Data Storage Automatic store & copy; No time and volume limit; Lifetime preservation
Print format Can be set up, offer several standard format
Calibration mode Linear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standard
Quality control methods : Real time, within day & between day
Quality control diagram L-J \cumulative\twin plot
Status display Real time monitoring of reagent residual volume .Running status of reagent tray, samples tray
Adjustment Dynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messages         
Setting Operation permission setting, Item setting, cross pollution setting, cuvette blank setting
Others
Water consumption : < 18L/h Power Supply :AC 220V-240V 50/60Hz 1000W or 100V-200V 60HZ 1000W
Frequency :Maximum 600VA Dimension :912mm×721mm×570mm
Net Weight : 60kg Accessory :Software
 
     
Note:We provides you with12-24 months free repair guarantee for main unit, 12 months free repair guarantee for probe and 6 months free repair guarantee for the optional parts respectively.More information for our products and service,please turn to our official website or contact us directly.

Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine
 
 Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine

Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine
Venezuela Popular Medical 300 Tests Automatic Chemistry Analyzer MachineVenezuela Popular Medical 300 Tests Automatic Chemistry Analyzer MachineVenezuela Popular Medical 300 Tests Automatic Chemistry Analyzer MachineVenezuela Popular Medical 300 Tests Automatic Chemistry Analyzer Machine

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now