• UK Original Power Brand Diesel Generator Set 2 Megawatt Generator
  • UK Original Power Brand Diesel Generator Set 2 Megawatt Generator
  • UK Original Power Brand Diesel Generator Set 2 Megawatt Generator

UK Original Power Brand Diesel Generator Set 2 Megawatt Generator

After-sales Service: 1 Year/1000 Hours
Warranty: 1 Year/1000 Hours
Type: Micro-Computer Control Automatic Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GS-P2000KW
Output Type
AC Three Phase
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Engine Model
4016
Alternator
Stamford/Leroy Somer
Model
Open Type/Silent Type/Trailer Type/Container Type
Fuel Tank
8 Hours Base Fuel Tank
Controller
Comap/Smartgen
Alternative
Installing with ATS
Color
Depends on
Frequency
50Hz
Voltage
400V/230V 380V/220V 3 Phase
Transport Package
Wooden Package
Specification
40HQ container
Trademark
Gspark
Origin
Fujian
HS Code
8502
Production Capacity
2500/Month

Product Description

Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.

With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.




UK Original Power Brand Diesel Generator Set 2 Megawatt Generator

UK Original Power Brand Diesel Generator Set 2 Megawatt Generator
UK Original Power Brand Diesel Generator Set 2 Megawatt Generator



UK Original Power Brand Diesel Generator Set 2 Megawatt Generator
UK Original Power Brand Diesel Generator Set 2 Megawatt Generator




UK Original Power Brand Diesel Generator Set 2 Megawatt Generator
UK Original Power Brand Diesel Generator Set 2 Megawatt Generator


 
Powered by PERKINS | 400V, 1500RPM, 50Hz
Genspark Standby Prime Engine Alternator Dimension mm Dimension mm Fuel Cons Displacement Cylinder Gov
Model kVA kVA Model Stamford Open Type Soundproof Type 75%(L/H) L
GS-P16 16.5 15 403A-15G2 S0L1-P1 1300*690*1320 1710*880*1350 3.3 1.496 3 M
GS-P22 22 20 404D-22G S0L2-G1 1470*690*1320 1910*880*1450 4.1 2.216 4 M
GS-P34 33 30 1103A-33G S0L2-P1 1760*760*1380 2290*1060*1680 5.3 3.3 3 M
GS-P65 65 60 1103A-33TG2 S1L2-Y1 1760*760*1380 2290*1060*1680 10.8 3.3 3 M
GS-P70 71.5 65 1104A-44TG1 UCI 224F1 1760*760*1380 2440*1060*1680 10.9 4.4 4 M
GS-P88 88 80 1104A-44TG2 UCI 224G1 2000*900*1550 2810*1140*1830 14 4.4 4 E
GS-P110 110 100 1104C-44TAG2 UCI 274C1 2150*900*1550 2810*1140*1830 16.8 4.4 4 E
GS-P200 200 182 1106A-70TAG3 UCI 274G1 2550*930*1670 3590*1250*2050 30.2 7.01 6 M
GS-P220 220 200 1106A-70TAG4 UCI 274H1 2550*930*1670 3590*1250*2050 33.7 7.01 6 M
GS-P275 275 250 1506A-E88TAG3 UCDI 274K1 2580*930*1670 3590*1250*2050 39.4 8.8 6 E
GS-P400 400 350 2206C-E13TAG2 S4L1D-E41 3100*1120*1788 4230*1460*2150 64 12.5 6 E
GS-P450 450 400 2206C-E13TAG3 S4L1D-F41 3100*1120*1788 4230*1460*2150 72 12.5 6 E
GS-P500 500 450 2506C-E15TAG1 S4L1D-G41 3400*1270*1974 4630*1660*2250 73 15 6 E
GS-P550 550 500 2506C-E15TAG2 HCI 544C1 3400*1270*1974 4630*1660*2250 82 15 6 E
GS-P700 700 635 2806A-E18TAG2 HCI 544FS1 3600*1400*2100 5030*1660*2550 95 18.13 6 E
GS-P720 715 650 2806A-E18TAG2 HCI 544F1 3600*1400*2100 5030*1660*2550 97 18.13 6 E
GS-P825 825 750 UK 4006-23TAG2A LV1 634B1 3965*1710*2200 5800*1800*2550 119 22.921 6 E
GS-P880 880 800 UK 4006-23TAG3A S6L1D-C4 3965*1710*2200 5800*1800*2550 131 22.921 6 E
GS-P880 880 800 India 4006-23TAG3A S6L1D-C4 3965*1710*2200 5800*1800*2550 131 22.921 6 E
GS-P1100 1100 1000 UK 4008TAG2A  S6L1D-E4 4650*2046*2300 ISO 20'ft GP 158 30.561 8 E
GS-P1100 1100 1000 India 4008TAG2A S6L1D-E5 4650*2046*2300 ISO 20'ft GP 158 30.561 8 E
GS-P1250 1250 1125 India 4008-30TAG3 S6L1D-F4 4650*2046*2300 ISO 20'ft GP 176 30.561 8 E
GS-P1375 1375 1250 UK 4012-46TWG2A S6L1D-G4 4700*1780*2400 ISO 20'ft GP 209 45.842 12V E
GS-P1650 1650 1500 UK 4012-46TAG2A S7L1D-C4 5000*2200*2850 ISO 40'ft HQ 236 45.842 12V E
GS-P1650 1650 1500 India 4012-46TAG2A S7L1D-C4 5000*2200*2850 ISO 40'ft HQ 236 45.842 12V E
GS-P1800 1812.5 1650 India 4012-46TAG3A PI 734D1 5100*2200*2850 ISO 40'ft HQ 264 45.842 12V E
GS-P1875 1875 1705 UK 4012-46TAG3A S7L1D-E4 5100*2200*2850 ISO 40'ft HQ 272 45.842 12V E
GS-P2000 2000 1850 India 4016TAG1A S7L1D-F4 5400*2650*2650 ISO 40'ft HQ 281 61.123 16V E
GS-P2000 2000 1850 4016-61TRG1 S7L1D-F4 5400*2650*2650 ISO 40'ft HQ 277 61.123 16V E
GS-P2250 2250 2050 4016-61TRG2 PI 734F or S7L1D-G4  5400*2650*2650 ISO 40'ft HQ 309 61.123 16V E
GS-P2250 2250 2050 India 4016TAG2A PI 734F or S7L1D-G4 5400*2650*2650 ISO 40'ft HQ 318 61.123 16V E
GS-P2500 2500 2272.5 UK 4016-61TRG3 S7L1D-J4 or PI 734H1 6000*2700*3400 ISO 40'ft HQ 354 61.123 16V E
GS-P2500 2500 2272.5 India 4016-61TRG3 S7L1D-J4 or PI 734H1 6000*2700*3400 ISO 40'ft HQ 354 61.123 16V E


UK Original Power Brand Diesel Generator Set 2 Megawatt Generator

UK Original Power Brand Diesel Generator Set 2 Megawatt Generator






UK Original Power Brand Diesel Generator Set 2 Megawatt Generator








-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
Icon Indicator Light Reason Fault Analysis and Solve Method
High Water Temperature Alarm High Water Temperature Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure Alarm Low Oil Pressure Alarm When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level Alarm Low Fuel Level Alarm When Fuel level has been detected by sensor fitted to the daily tank,the light is off. Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault Alarm Battery Charger Fault Alarm The Charing System has fault while engine still running,the light is off. Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure Alarm Crank Failure Alarm When Generator set fail three times(or six times) in arow starting,the light is on It is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping Alarm Overload or Breaker Tripping Alarm When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.


 
It would be great honor to receive your inquiry and direct contact! 























 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14000
Terms of Payment