• Transformer Polarity Ratio Analyzer CT PT Characteristic Knee Point Tester
  • Transformer Polarity Ratio Analyzer CT PT Characteristic Knee Point Tester
  • Transformer Polarity Ratio Analyzer CT PT Characteristic Knee Point Tester
  • Transformer Polarity Ratio Analyzer CT PT Characteristic Knee Point Tester
  • Transformer Polarity Ratio Analyzer CT PT Characteristic Knee Point Tester
  • Transformer Polarity Ratio Analyzer CT PT Characteristic Knee Point Tester

Transformer Polarity Ratio Analyzer CT PT Characteristic Knee Point Tester

Type: Universal Testing Machine
Display: LCD
Control: Computer Control
Weight: Less Than 22kg
Power Source: 220V or 120V at Customized
Single Machine Output: 0-2500vrms, 5kVA (Maximum Setting Value 20A)
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
EPCP-III
Primary Current Output
0-1000A
Excitation Accuracy
Less Than 0.5% (0.2%*Reading+0.3%*Range)
Secondary Winding Resistance Measurement
0.1-300ohm
Secondary Real Load Measurement
5-500va
Phase Measurement (Angle Difference)
4min
Resolution
0.1min
CT Ratio Measurement Range
Less Than 25000A/5A(5000A/1A)
PT Ratio Measurement Range
Less Than 500kv
Operating Temperature
-10~+40degree
Relative Humidity
Less 90rh%
Altitude
Less Than 1000m
Current Transformer (CT)
Auto Calculation of Knee Point Value
Polarity
Yes
Transport Package
Plywood Case with Warter Proof Plastic
Specification
410mm*260mm*340(mm)
Trademark
EP Hipot Electric
Origin
China
HS Code
9030820000
Production Capacity
2000/Year

Product Description

EPCP-III
CT/PT Analyzer (Full Functions)

General Information:
EPCP-III is portable analyzer designed for analyzing current transformers and voltage transformers of protection or measurement use, which is suitable for laboratory and on-site test.

Features:
  • Support detection of CT and PT
  • No need to connect other auxiliary equipment, can complete all test items, and complete the excitation and transformation ratio polarity test at the same time in one test.
  • Fast printer, which can print test results directly on site.
  • Easy to operate, with intelligent prompts, making it easier for users to operate.
  • Large screen LCD, graphical display interface.
  • Automatically give CT/PT (excitation) inflection point value according to regulations.
  • Automatically give 5% and 10% error curves.
  • 3000 sets of test data can be saved, which will not be lost after power failure.
  • Support U disk transfer data, can be read through a standard PC, and generate WORD report.
  • Small and light weight 22kg, very conducive to field testing.
 
Main Test Functions:

1. Function Table
 
I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Excitation Characteristic Test 1. Excitation Characteristic Test
2. Auto Calculation of Knee Point Value 2. Auto Calculation of Knee Point Value
3. Auto 5% and 10% error curves, can measure ALF 3. Transformer Ratio Test
4. Transformer Ratio Test 3. Polarity
5. Polarity 4. Ratio difference measurement
6. Ratio difference measurement 5. Phase (angle difference) measurement
7. Phase (angle difference) measurement 6. Withstand Test of Power Frequency Alternating Current
8. Primary Current Injecting 7. Actual Secondary Load Test
9. Withstand Test of Power Frequency Alternating Current 8. Secondary Winding Test
10. Secondary Load Test  
11. Secondary Winding Test  
12. Measuring the volt-ampere characteristics of medium and low voltage CTs and zero sequence CTs  
13. Measure GIS, casing CT  
14. Comprehensive test, complete excitation and transformation ratio polarity at the same time in one test  

2. Technical Parameter Table
 
Operational Power Supply: AC220V±10%, 50Hz
Single Machine Output: 0~2500Vrms, 5kVA (maximum setting value 20A)
Primary Current Output: 0~1000A
Excitation accuracy ≤0.5% (0.2%*reading+0.3%*range)
Secondary winding
Resistance measurement
Range 0.1~300Ω
Accuracy ≤0.5% (0.2%*reading+0.3%*range)
Secondary real
Load measurement
Range 5~500VA
Accuracy ≤0.5% (0.2%*reading+0.3%*range) ±0.1VA
Phase measurement
(Angle difference)
Accuracy 4min
Resolution 0.1min
CT ratio measurement range Range ≤25000A/5A(5000A/1A)
Accuracy ≤0.5%
PT ratio measurement range Range ≤500KV
Accuracy ≤0.5%
Operating Temperature: -10ºC~+40ºC
Relative Humidity:   <90RH%
Altitude: ≤1000m
Overall Dimension (Length × Width × Height): 410mm * 260mm * 340(mm)
Weight: ≤22 kg
More details about CTPT Analyser EPCP-III please contact EPHipot Electric, we have professional tech team to design correctly designed products and systems.

Transformer Polarity Ratio Analyzer CT PT Characteristic Knee Point Tester
Transformer Polarity Ratio Analyzer CT PT Characteristic Knee Point Tester
Transformer Polarity Ratio Analyzer CT PT Characteristic Knee Point Tester


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now