Temperature and humidity thermostat, control one heater and one exhaust fan with one probe
.
Heater Start Condition : the ambient humidity ≤ the heater setting point TL
,or ambient humidity ≥ humidity setting point HH
under Auto mode.
Heater Shutdown Condition: the ambient humidity ≥ the heater setting point TL+5°C ,and ambient humidity ≤ humidity setting point HH -5%RH under Auto mode.
Fan Start Condition : the ambient humidity 2 ≥ the temperature setting point TH under Auto mode.Start the exhaust fan to cool down.
Fan Shutdown Condition: ambient humidity 2 ≤ humidity setting point TH -5°C under Auto mode.The exhaust fan exits to cool down.
Main Technical Characteristics
Temperature Measurement Range: -40.0ºC~105.0ºC Precision: ±0.5ºC
Humidity Measurement Range: 0~99.9%RH Precision: ±5%RH
Working Environment: -40ºC~85ºC Power: AC/DC 85~265V(AC&DC)
Dimension: 48mm×48mm×90mm Hole Opening Size: 45.5mm×45.5mm
Output Contact Capacity: AC220V/5A, Two-way relay are active outputs.