• HVHIPOT Secondary Burden Test Ratio Error Tester for Current/Voltage Trnasformer (GDHG-206)
  • HVHIPOT Secondary Burden Test Ratio Error Tester for Current/Voltage Trnasformer (GDHG-206)
  • HVHIPOT Secondary Burden Test Ratio Error Tester for Current/Voltage Trnasformer (GDHG-206)
  • HVHIPOT Secondary Burden Test Ratio Error Tester for Current/Voltage Trnasformer (GDHG-206)
  • HVHIPOT Secondary Burden Test Ratio Error Tester for Current/Voltage Trnasformer (GDHG-206)

HVHIPOT Secondary Burden Test Ratio Error Tester for Current/Voltage Trnasformer (GDHG-206)

After-sales Service: YES
Warranty: 1
Usage: CT/PT calibrator
Power: Electricity
Certification: CE
CT Turn Ratio Range: 5A/5A- 25000A/5A (5A/1A- 5000A/1A)
Customization:

360° Virtual Tour

Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GDHG-206
PT Turn Ratio Range
Full range measurement ±0.2%
Accuracy of PT/CT Error
±0.05%
CT Secondary Burden
1-25 ohm ±2%
PT Secondary Burden
1VA-500VA ±2%
Ratio Error
0.001%-3% (100V)
Angle Error
0.00′-50′ (100V)
Delivery Time
15 days
Transport Package
Wooden Case
Specification
ISO, SGS
Trademark
HV Hipot
Origin
Wuhan, China
HS Code
9030849000
Production Capacity
5000 Sets/Year

Product Description

HVHIPOT Secondary Burden Test Ratio Error Tester for Current/Voltage Trnasformer (GDHG-206)


General introduction

GDHG-206 CT/PT On-site Calibrator is designed for analyzing current transformers and voltage transformers of ratio error, angle error, ratio error/angle error of 1%-200% current. It can directly measure turns ratio and polarity, actual secondary burden of CT/PT.
The model uses DC and AC power supply with high precision and automatic linear adjustment. High speed and reliable digital processing module is also adopted.

Different types

  • GDCT-103B CT On-site Calibrator(with white screen)
  • GDCT-103C CT On-site Calibrator (with true color big screen)
  • GDPT-103 PT On-site Calibrator
  • GDPT-103C CVT On-site Calibrator

Specifications

CT Turn Ratio Range 5A/5A- 25000A/5A (5A/1A- 5000A/1A)
Turn ratio error ±0.2%
PT Turn Ratio Range Full range measurement ±0.2%
Accuracy of PT, CT Error ±0.05%
DC Resistance 0.0-0.1ohm ±3%
0.1-50 ohm ±1%
CT Secondary Burden 1 ohm -25ohm ±2%
PT Secondary Burden 1VA-500VA ±2%
Ratio Error 0.001%-3% (100V)
Angle Error 0.00'-50' (100V)
Admittance 0.1ms-99.9ms
Error X= ±(2%×X+2%×Y±2digit), Y= ±(2%×X+2%×Y±2digit)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now