• Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions
  • Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions
  • Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions
  • Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions
  • Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions
  • Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions

Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions

Application: Electronic, Instrument
Type: Current Transformer
Phase: Single
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions pictures & photos
Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions
US $4.6-5.5 / Piece
Min. Order: 1 Piece
Gold Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company, Other, Group Corporation

Basic Info.

Model NO.
SCT series
Operation Condition
Indoor
Usage
Protection, Measurement
Winding Form
Multilayer Honeycomb Type
Insulating Medium
Insulating Paper
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Capacitive Type
Model
Sct Split-Core Current Transformer
Window Size
19*19 Mm / 32*32 Mm / 52*52 Mm
Rated Input
5A-5000A
Rated Output
0.333V(AC) or 0-500mA
Frequency
50-60Hz
Ratio
± 1.0%
Case
PC /UL94-V0
Bobbin
PBT
Core
Permalloy
Is_Customized
Yes
Transport Package
Export Foam Box
Specification
CE, ISO, RoHs
Trademark
HEYI
Origin
Liushi, Yueqing, Zhejiang Province, China
HS Code
8504311000
Production Capacity
100000PCS/Month

Packaging & Delivery

Package Size
5.00cm * 5.00cm * 5.00cm
Package Gross Weight
0.400kg

Product Description


Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions
SCT series retro-fit (split-core) current transformer has been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar circuit. An internal precision resistor across the secondary winding of the CT provides a low safe voltage output. It can save time and the installation costs.
 

Features             

1) Split core design, safe, easy to install, portable.

2) Wide inner window, allowing clamping of big cables or bus-bars

3) Wide range of sizes to accommodate all the existing installations

4) Wires plugs, Audio plugs, Power plugs and so on five kinds of plugs

 

 Specification  

Current Ratio 50A/10mA 100A/20mA 200A/33.3mA 200A/0.333V
Primary Current (A) 50A 100A 200A 200A
Max. Current (A) 60A 120A 240A 240A
Output 10mA 20mA 33.3mA 0.333mV
Load Resistance (Ω) 50Ω 50Ω 20Ω /
Turns Ration        
Class 1.0 1.0 1.0 1.0
Protection Level 7.5V0-P
Insuliation Category CATIII
Operating Condition  -20ºC ~ +50ºC85%RH, No condensation, IN-house & Any direction installable
Storage Condition  -30ºC ~ +50ºC85%RH, No condensation
 
Model                                                       SCT-32
Current Ratio 200A/40mA 300A/60mA 400A/40mA 600A/60mA 400A/0.333V
Primary Current (A) 200A 300A 400A 600A 400A
Max. Current (A) 240A 360A 480A 720A 480A
Output 40mA 60mA 40mA 60mA 0.333V
Load Resistance (Ω) 50Ω 50Ω 50Ω 25Ω /
Turns Ration 5000:1 5000:1 10000:1 10000:1 /
Class 1.0 1.0 1.0 1.0 1.0
Protection Level 7.5V0-P
Insuliation Category CATIII
Operating Condition  -20ºC ~ +50ºC85%RH, No condensation, IN-house & Any direction installable
Storage Condition  -30ºC ~ +50ºC85%RH, No condensation
 
 
Model                                                             SCT-52
Current Ratio 500A/25mA 600A/30mA 1000A/50mA 1500A/75mA 800A/0.333V
Primary Current (A) 500A 600A 1000A 1500A 800A
Max. Current (A) 600A 720A 1200A 1600A 960A
Output 25mA 30mA 50mA 60mA 0.333V
Load Resistance (Ω) 50Ω 50Ω 50Ω 25Ω /
Turns Ration 20000:1 20000:1 20000:1 20000:1 /
Class 1.0 1.0 1.0 1.0 1.0
Protection Level 7.5V0-P
Insuliation Category CATIII
Operating Condition  -20ºC ~ +50ºC85%RH, No condensation, IN-house & Any direction installable
Storage Condition  -30ºC ~ +50ºC85%RH, No condensation
 

Note: The Current Ratio above are common type, that's ok to customise the ration according to customers' requirement.


Graph  
Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions

 

 Applications           

1) Current measurement, monitoring and protection for electrical wiring and equipment.

2) Current and power measurement for electric motors, lighting, air compressor, heating

and ventilation system, air-condition equipment and automation - control system.

3) Current, power and energy monitoring device.

4) Relay protection device.


 The advantages of HEYI SCT   
Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions


How to Order?
1. Please let us know what kind of model, color, poles and rated current etc.
2. Proforma invoice (PI) will be sent to you.
3. Please check and confirm the PI.
4. Once we confirmed the order, please pay it soon.
5. After full payment, all goods will be sent to you in 6-10 days as usual.
6. OEM/ODM is welcomed. Free OEM for more than 5000 sets orders. 
 
Shipping:
1. Products are shipped via UPS / DHL / EMS / HK EMS / FedEx / TNT and so on expresses (door to door).
2. We Provide Drop shipping Service.
3.5 days delivery upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
4. In order to ensure you receive your order tax free upon import, we declare lower value.
5. Shipping via EMS. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 
 
Payment:
1. We accept Western Union and T/T
2.30% deposit and 70% before shipping
3. No payment collection. We only can deliver goods after getting full payment. 
 
Warranty:
1. We provide 1 year warranty.
2. If the product is defective, please notify us within 3 days of delivery.
3. All products must be returned on their original condition, in order to qualify for a refund or exchange of goods


Our Commitment:                                                                                                                                                          
BETTER PRICE than other suppliers for you because of Factory Direct Sale;
BETTER QUALITY than before caused by our 10+ years experience about CT;
STOCK IN TRADE awlays own to our Fast & Professional production line;
FAST DELIVERY as awlays made by our GROUP's Enthusiam;
TIMING REPLY in 24 hours all about our TEAM's Passion & Patience.
 
FAQ:
1) What is the difference between a moulded case current transformer and a split core current transformer?

A moulded case current transformer is a solid ring of steel in a plastic or resin case and can only be used when you fit the cable through the hole in the middle of the plastic/resin case.
 
A split core current transformer is manufactured with the steel core in two pieces. This enables the core to be separated, allowing you to fit the cores around the cable without disconnecting the cables. The disadvantage with split core current transformers is that they can be larger than standard moulded case and the price is approximately four times more expensive.

2) Which way round do the Current Transformers go?
The current transformers must be fitted and connected in the correct way or the meter will not be accurate. The current transformers are marked on two sides: 'P1' and 'P2.' 'P1' must face the mains side and 'P2' must face the load side. 'S1' must be connected to the main side of the meter and 'S2' to the load side. Refer to appropriate wiring diagram of the meter for correct connections.

3) Can the current transformers be a higher or lower ratio then my maximum load?

The current transformers should ideally be about 80% of the normal running load, thus allowing a 20% allowance of increasing the load in the future. 

Contact us:
Send your Inquiry Details in the Below, Click "Send" Now!
YOUR BENEFITS IS OUR BUSINESS!!!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions pictures & photos
Sct Low Voltage Precision Split Core Current Transformers Ma or 333mv Output Clamp on Current Transducer Energy Management Solutions
US $4.6-5.5 / Piece
Min. Order: 1 Piece
Gold Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company, Other, Group Corporation
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
OEM/ODM Availability
Yes