Model | S-1500-12 | S-1500-24 | S-1500-36 | S-1500-48 | |
DC Voltage | 12V | 24V | 36V | 48V | |
Rated Current | 110A | 62.5A | 41.7A | 31.25A | |
Current range | 0~110A | 0~62.5A | 0~41.7A | 0~31.25A | |
Rated power | 1320W | 1500W | 1501.2W | 1500W | |
Ripple&noise | 200mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | |
Voltage ADJ. | 12~14V | 24~28V | 36~38V | 48~53V | |
Efficiency | 82% | 83% | 83% | 83% | |
105%~150% in rated output power | |||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||
15~16.5V | 29~33V | 40~45V | 58~65V | ||
Protection mode,tum off output voltage, restart to recover | |||||
Fan switch control | The fan turn straight | ||||
over-temperature protection | RTH3:≥60ºC Fan turn fast ≥90ºCClose the output |
Q1:What is your MOQ of switch power?