• Roots Type Gas Meter (LNG) Without Valve/Gas Detector
  • Roots Type Gas Meter (LNG) Without Valve/Gas Detector
  • Roots Type Gas Meter (LNG) Without Valve/Gas Detector

Roots Type Gas Meter (LNG) Without Valve/Gas Detector

Warranty: 1 Years
Kind: Roots Type Gas Meter
Diameter: 25-50mm
Samples:
US$ 80/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Roots Type Gas Meter (LNG) Without Valve/Gas Detector pictures & photos
Roots Type Gas Meter (LNG) Without Valve/Gas Detector
US $58.2-61.3 / Piece
Min. Order: 1 Piece
Gold Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company, Other, Group Corporation

Basic Info.

Model NO.
G6
Precision Grade
0.015
Application
Civil, Industrial
Starting Flow
0.016 M³/H
Type
G6
Medium Temperature
-25~+55ºC
Ambient Temperature
-20~+40ºC
Nominal Pressure
20~80 Kpa
Transport Package
Box
Trademark
HEYI
Origin
Liushi, Yueqing, Zhejiang Province, China
HS Code
8443999090
Production Capacity
10000PCS/Year

Product Description

Introduction

Suitable for measuring natural gas, liquefied gas, gas, methane, carbon dioxide, oxygen and other rare gases. The measured gas shall be monophase gas (including air) and free of impurities such as particles and fibers.

Working principle

When the gas passes through the flow meter, the pressure difference generated at the outlet and inlet acts on a pair of Roots wheels coupled with a high-precision synchronous gear, thereby driving the Roots wheels to rotate. The Roots wheels are connected to the inner wall of the housing and the gland Between the inflation and exhaust of the enclosed space formed between cycles, the rotation speed of the Roots wheel is proportional to the volume of gas passing through the flow meter.
Product display
Roots Type Gas Meter (LNG) Without Valve/Gas DetectorRoots Type Gas Meter (LNG) Without Valve/Gas Detector
Technical parameter
Technical parameter name
Description
Nominal Diameter
25/20 mm
Flow-rate range
0.08~10 m³/h
Startup flow rate
0.016 m³/h
Maximum pressure loss
0.10 KPa
range ratio
64:1
Nominal Pressure
20~80 KPa
Connection type
Intubation
Ambient temperature
-20~+40ºC
Medium temperature
-25~+55ºC
Relative humidity
5~9%
Atmospheric pressure
70~106KPa

Product features

1.The circuit adopts surface mount technology, with compact structure, strong anti-interference ability and high stability
2. High performance microwave processor and modern microwave technology, precision processing, powerful performance
3. Waist wheel measurement, low pressure loss, high precision, low maintenance, high reliability, can measure weak airflow

Product advantage

1. Compact structure and strong stability:The surface mount technologyis adopted on the circuit, which has compact structure, strong anti-interference ability and high stability.
2. Precision head: the meter head adopts high-techwhich has stable structure, strong anti-interference ability, and accurate reading.
3. Superb technology:Itadoptshigh-performance microwave processor and modern microwave technology, with precise processing and powerful performance.
4. Waist wheel measurement: small pressure loss, high accuracy, low maintenance, high reliability, anditcan measure weak airflow also.
5. Double protection: Double-layer reinforced bodyand integrally formedmake it strong and durable; the lead seal can prevent cheating operation.

Communication mode :

1. LORAWAN
(1)Component: Lorawan has four parts
Node: gas meter, water meter, position , alertor etc.
Gateway: receiving data
Network platform : Management of equipment in base station, DNSEG control etc.
User's data background : data storage and application processing for user
Roots Type Gas Meter (LNG) Without Valve/Gas Detector
The main chip of LORAWAN communication module adopts the high-performance embedded ARM cortex-m3 32-bit RISC controller, which
ensures the stability of the device with multilevel software detection and multiple hardware protection mechanisms.It is composed
of the powerful ARM cortex-m3 32-bit RISC microcontroller and Lorawan wireless spread spectrum chip .
(2)Product features:
1. measurement function
* real-time pulse counter accumulates flow
* strong magnetic detection trigger alarming info.
2. historical data store locally
* the data during latest 90 days store every one hour
* the data during the latest 180 days stores everyday
* the data during the latest 1 year stores every month
3. Power supply: one main battery for supplying daily , another one for spare battery
4. Main battery capacity level indicator
* In each measurement data consumption on the road up the service reported to the battery capacity level suffixü
* Low battery threshold :when the battery capacity is less than 20%, it will trigger low battery alarm and the low battery
alarming info.will be reported every 24 hours untill spare battery switch threshold
* Battery switch threshold : capacity of 10% will trigger the switch of spare battery
5. Spare battery switch only in the following cases; otherwise, use the main battery.
* Pull out the battery or the battery does not exist
* the main battery theshold is 10%
* The switch of spare battery is automatic so that i will not be outage
6. Spare battery function
* Water flow control partial measurement
* historical data storage
* spare battery exceeds 7 days at least
* When spare battery is used , the alarming info. Of spare battery will be reported to server
7. The spare battery protection in transportation
* Prior to on-site activation, the meter is equipped with only spare batteries, and in the warehouse or during transportation,
protection will be provided to prevent the consumption of the spare batteries.
8. Battery life: 6
9. operating temp.:-5~+ 85ºC
10. LED indicator: indicates LORA event
11. Manual triggering lorawan uplink for testing
12. Wireless technology: lorawan in EU868
13. LoRaWAN class: class A
14. LoRaWAN reports regularly measured data for a period of 24 hours by default
The message payload includes
* the latest accumulated measured data
* statue of meter: valve,power, strong magnetic detection
* battery capacity
* lorawan downlink signal indicator RSSI/SNR
15. LoRaWAN fixed time metering data report (ON/OFFconfigurable).LoRaWAN metering data report is triggered every day at fixed time
(e.g. 23:00, configurable), and the message payload is the same as the periodic report
* the latest accumulated measured data
* statue of meter: valve,power, strong magnetic detection
* battery capacity
* lorawan downlink signal indicator RSSI/SNR
16. LoRaWAN alarming info. Uplink report
* low battery alarm
* spare battery switch alarm
* valve error alarm
* strong magnetic detection alarm
17. LoRaWAN downlink set/inquire
* Set up/query LoRaWAN periodic metering data report cycle
* Fixed time measurement data report/switch/set up/inquiry/time
* Modify accumulated water flow data for calibration
* read the data of current accumulated water flow
* battery capacity reading
* valve control switch
Roots Type Gas Meter (LNG) Without Valve/Gas DetectorRoots Type Gas Meter (LNG) Without Valve/Gas Detector
 

Product operating environment

1.temperature:-10ºC~40ºC;
2.working pressure:0.5kPa~30kPa;
3.relative humidity:≤93%;
4.atmospheric pressure:86kPa~106kPa;
5.This series of gas meters is applicable to the measurement of urban pipeline gas, natural gas and liquefied petroleum gas;
6.The gas used should comply with the relevant provisions of the state, can not contain water to prevent condensation water will
be frozen meter;
7.It should be installed in a dry and ventilated place, strictly prohibited in the bedroom or bathroom;
8.It should not be installed in the place of serious corrosion to the table;
9.Adequate safe distance from furnace and other sources of fire;
10.In order to avoid condensed water into the table, the table should be installed horizontally at the high point of the pipeline.
 

Installation and safety matters

1.Before installation, the gas meter should be inspected first for appearance and then for sealing performance, so as to prevent installation and use of the gas meter that may cause damage during transportation.
2.When installing the gas meter, it should be noted that the distance between the center of the pipeline connected with the gas meter should be consistent with the distance between the center of the gas meter. It should not be forced to connect and twist to avoid leakage at the connection of the gas meter.
3.The gas meter should have sufficient safe distance from the stove and other fire sources.
4.Keep in mind:The air in the pipeline and gas meter should be emptied before ignition.Gas mixed with air can easily explode when it meets spark.
5.During transportation, storage and installation of gas meters, care should be taken to prevent falling upside down and water entering.
6.The fuel gas used should meet the requirements of the national standards and should not contain moisture. The condensed water in fuel gas will freeze the table and cannot operate normally
7.In order to avoid condensate water into the gas meter, the gas meter should be installed horizontally at the high point of the pipeline when installation should pay attention to the top of the case arrow, indicating the direction of gas flow, should not be connected to the reverse (because the table has anti-retrograde device).
8.The gas meter should be installed in a dry and ventilated place. It is strictly prohibited to install the gas meter in the
bedroom and bathroom, and should not be installed in the place where the gas meter is seriously corroded.
9.When the pipeline system leaks, it is forbidden to leak the open fire. When the pilot fire is carried out, the air in the gas
meter must be discharged to prevent accidents
10.In case of malfunction, please do not disassemble by yourself, please ask the technical personnel of gas company for
maintenance.
11.In case of gas leakage, first close the front table valve, immediately open doors and Windows ventilation.
12.Do not use open fire leak detection, carefully with soap and water leak detection.
13.This meter can not be used in the use of strong caustic soda gasoline alcohol solvent cleaning.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Roots Type Gas Meter (LNG) Without Valve/Gas Detector pictures & photos
Roots Type Gas Meter (LNG) Without Valve/Gas Detector
US $58.2-61.3 / Piece
Min. Order: 1 Piece
Gold Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Trading Company, Other, Group Corporation
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram
OEM/ODM Availability
Yes