• 1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker
  • 1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker
  • 1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker
  • 1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker
  • 1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker
  • 1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker

1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Magnetic
Speed: High-Speed Circuit Breaker
Samples:
US$ 100/Bag 1 Bag(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker pictures & photos
1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker
US $2.21-3.25 / Piece
Min. Order: 100 Pieces
Diamond Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
STD32LE
Arc-extinguishing Medium
Air
Installation
DIN Rail
Structure
ELCB
Poles Number
4
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB, RCBO
Certification
ISO9001-2000, CE, CB, SAA
Standard
IEC 61009 GB16917
in
10, 16, 25, 32, 40A
Ue
230/400V
Pole
2p 4p
Transport Package
Inner Box/Carton
Specification
100pcs/ctns
Trademark
SONTUOEC, WZSTEC
Origin
Wenzhou Zhejiang
HS Code
853620000
Production Capacity
2000pieces/Week

Packaging & Delivery

Package Size
46.00cm * 24.00cm * 33.00cm
Package Gross Weight
0.025kg

Product Description

Product Description

Residual Current Circuit Breakers RCBO Electronic Type:

RCBO is applicable to electric circuits with rated voltage 230V AC, frequency 50/60Hz and rated current up to 40Amp. The RCBO provides indirect protection to the operator's body under such situation that the exposed live parts should be connected to a proper earth pole. 

Specifications

Sandard IEC/EN61009-1
Electrical
features
Mode   Electronic type 
Type(wave form of the earth leakage sensed)   A,AC
Thermo-magnetic release characteristic    B,C,D
Rated current In A 6,10,16,20,25,32A
Poles P 1P+N
Rated voltage Ue V AC 230
Rated Current :   6,10,16,20,25,32A
Rated sensitivity I△n A 0.01,0.03,0.1,0.3,0.5
Rated residual making and breaking capacity I△m A 500
Rated short-circuit capacity lcn A 4500
Break time under I△n S ≤0.1
Rated impulsewithstand voltage(1.2/50)Uimp V 4000
Rated frequency Hz 50/60
Dielectric test voltage at ind.Freq for 1min KV 2
Insulation voltage Ui V250  
Pollution degree   2
Mechanical
features
Electrical life t 4000
Mechanical life t 10000
Fault current Indicator   YES
Protection degree   IP20
Ambient temperature
(with daily average ≤35ºC)
ºC -5~+40(Special application please refer to temperature compensation correction )
Storage temperature ºC -25~+70
Installation Terminal connection type   Cable/U-type busbar/pin-type busbar
Terminal size top/bottom for cable mm2 25
AWG 18-3
Terminal size top/bottom for busbar mm2 25
AWG 18-3
Mounting   On DIN rail EN 60715(35mm)by means of fast clip device
Connection   From top

 


1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker1p+N a /AC RCBO 110/220V Ground Fault Circuit BreakerFAQ
Q 1. what's the payment term?   
A. We accept TT,30% deposit and 70% balance agaisnt copy of BL
Q 2. how's the delivery time ? 
A. usually it will take about 25 days for production
Q 3. tell me the standard of package?   
A. Normally are cartons, but also we can pack it according to your requirement.
Q 4.Would you accept to use our logo ? 
A.If you have good quantity,it absolute no problem to do OEM.
Q5. Can i take some samples?
A: Yes, we support to take samples before place the order. Just feel free to contact with us if you have any requirements.
Q6. Are you original Factory?
A: Yes, we have our own factory .
Q7. How can you make sure the quality of the products?
A: We will accord to international quality standards to inspect every item before leaving our factory.
1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker
1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker
Thanks for your reading.If any product meets your need.Welcome to send us an email.We are sure your any information can be attentioned without any delay.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker pictures & photos
1p+N a /AC RCBO 110/220V Ground Fault Circuit Breaker
US $2.21-3.25 / Piece
Min. Order: 100 Pieces
Diamond Member Since 2017

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory
Management System Certification
ISO 9001
Terms of Payment
LC, T/T, D/P, PayPal