Certification: SASO, CCC, ISO9001, CE
Working Medium: R410A
Heat Source Type: Air Source Heat Pump
Compressor: Gmcc
Capacity: 8.5kw, 15kw, 18kw, 20kw
Functions: Cooling + Heating+Hot Water
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
RF8I/bd RF2I/bd RF16I/bd RF20I/bd
Transport Package
Plywood Case
Specification
CE
Trademark
KONNEN
Origin
Zhejiang, China
HS Code
8418612090
Production Capacity
300 Units/Month

Product Description

DC INVERTER AIR TO WATER HEAT PUMP FOR COOLING, HEATING AND HOT WATER,
AIR SOURCE HEAT PUMP FOR COOLING, HEATING AND HOT WATER.


WE HAVE BOTH MONOBLOCK TYPE AND SPLIT TYPE.


WE offer OEM service!

KONNEN NEW FACTORY:
Residential Use DC Inverter Heat Pump System R410A Refrigent
WHY CHOOSE US:
Residential Use DC Inverter Heat Pump System R410A Refrigent
PRODUCT FEATURES:
Residential Use DC Inverter Heat Pump System R410A Refrigent
Residential Use DC Inverter Heat Pump System R410A Refrigent


World famous brands we cooperated for our heat pumps:
Residential Use DC Inverter Heat Pump System R410A Refrigent
Our Projects:
Residential Use DC Inverter Heat Pump System R410A Refrigent
Heat pump loading:

Residential Use DC Inverter Heat Pump System R410A Refrigent
Residential Use DC Inverter Heat Pump System R410A RefrigentResidential Use DC Inverter Heat Pump System R410A RefrigentResidential Use DC Inverter Heat Pump System R410A Refrigent
Parameters:
POLESTAR series DC INVERTER MONOBLOCK TYPE HEAT PUMP FOR COOLING & HEATING & HOT WATER
Model RF8I/bd RF12I/bd RF16I/bd RF20I/bd RF20II/bd
Power Supply V/Ph/Hz 220~240/1/50 380/3/50
Rated Condition 7ºC Heating Capacity (KW) 8.5 15 18 20 20
Power Input (KW) 2.66 4.36 5.21 5.88 5.88
COP 3.2 3.44 3.45 3.4 3.4
Nominal Condition -12ºC Heating Capacity (KW) 5.50  10.50  12.13  14.5 14.5
Power Input (KW) 2.33  4.40  5.05  6.01 6.02
COP 2.36  2.40  2.40  2.41 2.41
Low Temp. Condition -20ºC Heating Capacity (KW) 4.70  9.21  10.52  12.5 12.5
Power Input (KW) 2.47  4.56  5.18  6.25 6.25
COP 1.90  2.02  2.03  2 2
Low Temp. Condition -25ºC/Water output temp. 41ºC Heating Capacity (KW) 3.55  6.82  8.76  10.35 10.35
Power Input (KW) 2.20  4.21  5.03  6.02 6.02
COP 1.61  1.62  1.74  1.72 1.72
Low Temp. Condition -25ºC/Water output temp. 50ºC Heating Capacity (KW) 3.19  6.14  8.08  9.59 9.58
Power Input (KW) 2.28  4.23  5.69  6.81 6.81
COP 1.40  1.42  1.42  1.41 1.41
Rated Cooling Condition Cooling capacity (KW) 7.00  11.50  12.00  15.00  15.00 
Power input (KW) 2.64  4.34  4.61  5.75 5.74
EER 2.65  2.65  2.60  2.61 2.61
Max. power input (KW) 4.4 5.2 6.6 7.1 8.5
Max. current Without E-heater (A)  20 23.7 30 32.5 15.5
Max. Water Output Temp. Under Ambient Temp. -25ºC 58 58 58 58 58
Water resistance (kPa) 35 38 43 54 50
Noise Level dB(A) 59.5 61.5 61.5 62 63
Refrigerant  R410A R410A R410A R410A R410A
Water Flow 0.95 m³/h 1.98 m³/h 2.06 m³/h 2.5 2.5
Pipe Size DN20 DN25
Dimensions(mm) 920*365*710 940*393*1373
Net Weight 60Kg 130kg 130kg 140kg 145kg
Testing Condition:                                                                                                                          
- Rated condition: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
DC INVERTER SPLIT TYPE HEAT PUMP FOR COOLING & HEATING & HOT WATER
Model RF8I/bdm RF12I/bdm RF13I/bdm HF20I/bdm
Rated Heating Heating capacity kW 9.00 15.00 18.00 20.00
Power input kW 2.59 4.31 5.14 5.81
COP W/W 3.47 3.48 3.50 3.44
Nominal Heating Heating capacity kW 5.53 10.50 12.10 14.50
Power input kW 2.34 4.43 5.13 6.01
COP W/W 2.36 2.37 2.36 2.41
IPLV(H) W/W 2.80 2.85 2.85 2.86
Low Temp. Heating Heating capacity kW 4.50 8.90 10.10 12.50
Power input kW 2.34 4.56 5.10 5.95
COP W/W 1.92 1.95 1.98 2.10
Rated Cooling Cooling capacity kW 8.00 11.50 12.00 /
Power input kW 3.20 4.60 4.80 /
EER W/W 2.50 2.50 2.50 /
Power Supply V/Ph/Hz 220/1/50
Max. Power Input
(With E-Heater)
kW 4.4(+3) 5.2(+3) 6.6(+3) 7.1(+3)
Max. Current Input
(With E-Heater)
A 20(+13.6) 23.7(+13.6) 30(+13.6) 32.5(+13.6A)
Max. Water Temp.
(Without E-Heater)
ºC 58
Working Range
(Ambient temp.)
ºC -30 to 43 -35 to 43
Refrigeration Circulation Refrigerant Type R410A
Qty./Kg 1.7 3.15 3.15 3.15
Compressor Qty. 1
Type DC INVERTER DOUBLE ROTOR EVI DC INVERTER
DOUBLE ROTOR
Brand GMCC
Evaporator Type High efficiency hydrophilic aluminum foil fin heat exchanger
EEV Brand SANHUA
Fan Motor Qty. 1 2
Power
Input(W)
140 2*150
Fan Blades Size mm Φ560*139 Φ525*135
Liquid valve size inch(mm) 3/8"(9.52)
Gas valve size inch(mm) 5/8"(15.88)
Water system Condenser Type Tube in tube heat exchanger
Water Pump Brand XINHU
Model GPD25-12S
Water Flow m3/h 1.38 1.98 2.06 2.5
Water Drop kpa 35 35 38 48
Air Vent Valve / Standard
Pressure Release Valve / Standard
Pressure
value
3kgs
E-Heater kW 3
Buffer Tank L 5
Water
Inlet/Outlet Pipe
inch(mm) 5/4" male
Net Dimensions indoor Unit
(L*W*H)
mm 760x510x330
Outdoor Unit
(L*W*H)
mm 947x403x813 940x393x1373
Package Size indoor Unit
(L*W*H)
mm 795x562x373
Outdoor Unit
(L*W*H)
mm 1050x468x847 1060x490x1395
N.W. Indoor Unit kg 43
Outdoor Unit kg 63 110 115
G.W. Indoor Unit kg 48
Outdoor Unit kg 70 125 130
Noise Level Indoor Unit dB(A) ≤35
Outdoor Unit dB(A) ≤59.5 ≤61.5 ≤62
Product implementation standards: GB/T 25127.2-2010 GB/T 18430.2-2016 Testing Condition:
- Rated heating: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
- Internal and external machine connection copper pipe are 5m. If need for exceeds 7.5m, you need to contact the manufacturer to change the amount of refrigerant.