• Pulverized Coal Steam Boiler and Hot Water Boiler (WNS/SZS)
  • Pulverized Coal Steam Boiler and Hot Water Boiler (WNS/SZS)

Pulverized Coal Steam Boiler and Hot Water Boiler (WNS/SZS)

Function: Hot Water Boiler,Steam Boiler
Fuel: Coal-Fired
Installation: Assembled Boiler
Structure: Water Tube or Fire Tube
Media: Steam and Hot Water
Water Circulation: Natural Circulation
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Group Corporation

Basic Info.

Model NO.
WNS, SZS
Drum Placement
Horizontal Boiler
Pressure
Low and Medium Pressure
Manufacturing Level
A
Burning Style
Chamber Combustion Boiler
Usage
Industrial
Optional Pressure
0.7/1.0/1.25/1.6/2.5
Optional Temperature
According to Requirement
Applicable Fuel
Pulverized Coal
Gas Flow Type
Fire Tube or Water Tube
Certification
SGS, CE,Asme
Control System
PLC Optional
Transport Package
Exported Standard/According to Requirement; FCL
Specification
SGS, CE, ASME
Origin
China
HS Code
84021900
Production Capacity
500PCS/Year

Product Description

1. Central supplying of pulverized coal : Pulverized coal shall be centralized ground and integrated supply in the factory, ensuring high quality of pulverized coal .

2. Friendly work environment: The whole system shall use closeness running, automatic-coaling, and centralized ash discharge

3. Easy in starting and stopping for boilers: The boiler system shall achieve start- and -stop. It shall run normally following cutting off ignition source in 30 seconds. As soon as it cuts off coal dust supplying, the boiler system shall achieve blowing out.

4. High level of measuring and controlling: Automatic monitoring shall be used, as well as adjusting working parameter, as a result,the system shall be at its best running state, reducing the risk of boiler running on which labor intensity and human factor effect.

5. High-efficiency & energy-saving: The boiler shall featuret the following: Pulverized coal burning brightly,excellent heat transfer effect of boiler, low excess air coefficient of boiler , as well as high thermal efficiency of system . House-service equipment with high power shall use frequency-changer, economizing on electricity obviously.

6. Discharge kept shall be clean: Furnace desulfurating shall be performed in the pulverized coal boiler. Burner shall be equiped with cryogenic air classifier with uniform ignition temperature field, avoiding high-temperature , so the content of SO2 and NOX produced in combustion process is low. Fume shall employ bag filter with a low smoke dust level. Fly ash, collected by bag filter, shall be expelled from closed system, resulting in centralized treatment and utilization without secondary pollution.

7. Optimal land utilization: Coal storage and slag dump shall not be heaped around the boiler room, economizing on land and saving investment.
 
                  Boiler type   Items                                SZS1.4-0.7/95/70-AIII SZS2.8-0.7/95/70-AIII SZS4.2-0.7/95/70-AIII SZS5.6-0.7/95/70-AIII SZS7.0-1.0/115/70-AIII SZS14-1.25/130/70-AIII
Rated thermal power (MW) 1.4 2.8 4.2 5.6 7 14
Rated effluent pressure (MPa) 0.7 0.7 0.7 0.7 1 1.25
Rated effluent temperature°C 95 95 95 95 115 130
Rated return water temperature °C 70 70 70 70 70 70
Combustion mode Chamber combustion Chamber combustion Chamber combustion Chamber combustion Chamber combustion Chamber combustion
Applicable fuel pulverized coal pulverized coal pulverized coal pulverized coal pulverized coal pulverized coal
Thermal efficency %   ≥87   ≥87 ≥87 ≥87
The fuel consumption at full load operation (kg/h)   440   880 1085 2172
Maximum Weight of transportation cargo (t) 15 23 37 40 43 bulk
Maximum dimension of transportation cargo      (L×W×H)mm 5620×2890×3470 6330×3060×3525 8290×3080×3510 8790×3200×3572 9544×3580×3572 10080×4850×4825
 
                                  Boiler typer    Items WNS2-1.25-AIII WNS4-2.5-AIII WNS6-1.25-AIII WNS10-1.25-AIII
Rated output(t/h) 2 4 6 10
Rated working pressure(MPA) 1.25 2.5 1.25 1.25
Steam temperature °C saturated saturated saturated saturated
Feedwater temperature °C 20 20 105 105
combustion mode Chamber combustion Chamber combustion Chamber combustion Chamber combustion
Applicable fuel pulverized coal pulverized coal pulverized coal pulverized coal
Thermal efficency % ≥87   ≥87 ≥87
The fuel consumption at full load operation (kg/h) 236   615 1005
Maximum Weight o f transportation cargo (t) 11 27 39 45
Maximum dimension of transportation cargo                (L×W×H)mm 5865×2894×3426 5860×3060×3525 8865×2894×3426 11400×3230×3700
 
                           Boiler typer  Items                                           WNS1.4-0.7/95/70-AIII WNS2.8-0.7/95/70-AIII WNS4.2-0.7/95/70-AIII WNS7.0-1.0/115/70-AIII
Rated thermal power (MW) 1.4 2.8 4.2 7
Rated effluent pressure (MPa) 0.7 0.7 0.7 1
Rated effluent temperature°C 95 95 95 115
Rated return water temperature °C 70 70 70 70
Combustion mode Chamber combustion Chamber combustion Chamber combustion Chamber combustion
Applicable fuel pulverized coal pulverized coal pulverized coal pulverized coal
Maximum Weight of transportation cargo (t) 10 23 37 43
Maximum dimension of transportation cargo               (L×W×H)mm 5620×2100×2450 7430×2540×3080 8410×2880×3322 11416×3230×3682
 
                               Boiler type     Items SZS2-1.25-AIII SZS4-2.5-AIII SZS6-1.25-AIII SZS8-1.25-AIII SZS10-1.6-AIII SHS20-1.25-AIII
Rated output(t/h) 2 4 6 8 10 20
Rated working pressure(MPA) 1.25 2.5 1.25 1.25 1.6 1.25
Steam temperature °C saturated saturated saturated saturated saturated saturated
Feedwater temperature °C 20 20 105 105 105 105
Combustion mode Chamber combustion Chamber combustion Chamber combustion Chamber combustion Chamber combustion Chamber combustion
Applicable fuel pulverized coal pulverized coal pulverized coal pulverized coal pulverized coal pulverized coal
Maximum Weight o f transportation cargo (t) 17 27 39 42 48 In bulk
Maximum dimension of transportation cargo                (L×W×H)mm 5865×2894×3426 63700×3060×3525 8290×3080×3514 8790×3200×3576 9560×3580×3580 10100×4850×4825



Pulverized Coal Steam Boiler and Hot Water Boiler (WNS/SZS)
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2012

Suppliers with verified business licenses

Manufacturer/Factory, Group Corporation
Plant Area
101~500 square meters
Management System Certification
ISO 9001, ISO 14001, HACCP