• Micro Duct Cable with HDPE Sheath Installation by Air Blowing Gcyfxty-2/4/6/8/12/24b6a1
  • Micro Duct Cable with HDPE Sheath Installation by Air Blowing Gcyfxty-2/4/6/8/12/24b6a1

Micro Duct Cable with HDPE Sheath Installation by Air Blowing Gcyfxty-2/4/6/8/12/24b6a1

Application: Communication
Type: Single-mode Fiber
Connection Structure: No
Material Shape: Round Wire
Allowed Lateral Pressure: >1000(N/100mm)
Allowed Tensile Strength: >10000N
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Rating: 4.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
GCYFXTY
Core
Multicore
Certification
RoHS, CE, ISO9001, CCC, Tlc
Brand
OEM
Sheath Material
HDPE
Fiber Core
2~24cores
Fiber
G652D,G657A1
Installation
Mircro Duct, Air Blowing
Construction
Central Tube
Transport Package
Carton
Specification
4KM
Trademark
FCJ OPTO TECH
Origin
China
HS Code
85447000
Production Capacity
1000000km/Month

Product Description

Optical Fiber Cable Specification

Micro duct Cable with HDPE  Sheath
 for Installation by Blowing


GCYFXTY-2/4/6/8/12/24B6a1

                                                                             
  1. General
This specification covers the design and performance of the single mode optical cables to be used in air blown micro duct application.

Cable Description
  • 2/4/6/8/12/24 G657A1 SM-fibers..
  • Central tube structure
  • Suitable for air blown cable in micro-duct installation.
 
    1. Quality
FCJ GROUP ensures a continuing level of quality in our cable products through several programs including ISO 9001.
 
    1. Reliability
FCJ GROUP ensures product reliability through rigorous qualification testing of each product family.  Both initial and periodic qualification testing are performed to assure the cable's performance and durability in the field environment.
 
    1. Reference
ITU-T G.657.A1 Characteristics of a single-mode optical fiber
IEC 60794-1-1 Optical fiber cables- part1-1-Generic specification-General
IEC 60794-1-2 Optical fiber cables- part1-2-Generic specification-Basic optical cable test procedure
IEC 60794-3 Optical fiber cables- part3-Sectional specification- Outdoor cables
IEC 60794-5 Optical fiber cables- part5-Sectional specification- Microduct cabling for installation by blowing
    1. Working Condition
Transportation and storage temperature:-40ºC~+70ºC
Installation temperature: -5ºC~+60ºC
Operation temperature: -20ºC~+70ºC
 
    1. Minimum Allowable Bending Radius
Static: 10D
Dynamic: 20D
D is the out diameter of the cable
 
    1. Life Time
Optical fiber cables supplied in compliance with the specifications can be capable of withstanding the typical service condition  for a period of twenty-five (25) years without detriment to the transmission or operation and maintenance characteristics of the cable. 
 
  1. Optical Fiber In Cable(ITU-G657A1)
Optical properties of the SM fiber are achieved through a germanium doped silica based core with a pure silica cladding which meets ITU-T G657A1, UV curable acrylate protective coating is applied over the glass cladding to provide the necessary maximum fiber lifetime.
Geometrical, optical, and mechanical characteristics of fiber in cable as the following table:
 
Parameters Specification
Before cable After cable
Attenuation 1310 nm £ 0.35 dB/km £ 0.36 dB/km
1383 nm £ 0.35 dB/km £ 0.36 dB/km
1550 nm £ 0.25 dB/km £ 0.25 dB/km
1625 nm £ 0.25 dB/km £ 0.25 dB/km
Dispersion coefficient 1285 - 1340 nm ≥-3.4  £ 3.4 ps/(nm·km)
1550 nm £ 18 ps/(nm·km)
1625 nm £ 22 ps/(nm·km)
Zero dispersion wavelength   1300 - 1324 nm
Zero dispersion slope   £ 0.091 ps/(nm2·km)
Cable cut-off wavelength   £ 1260 nm
Polarization mode dispersion individual fibre £ 0.15 ps/Ökm
design link value (M=20, Q=0.01%) £ 0.1 ps/Ökm
Mode field diameter 1310nm 8.4~9.2 mm
1550nm 10.4 ± 0.5 mm
Cladding diameter   125.0 ± 0.7 mm
Cladding non-circularity   £ 1.0 %
Core concentricity error   £ 0.6mm
Coating diameter   245± 10 mm(Before Colored)
250 ± 15 mm (Colored)
Coating/cladding concentricity error   £ 12mm
Proof stress level   ³100kpsi (0.69 GPa)
Coating strip force(peak value)   1.3~8.9N
Macro bend induced attenuation 10 turns around 15mm radius @ 1550nm £0.25
 
10 turns around 15mm radius @ 1625nm £1.0
 
1 turn around 10mm radius @ 1550nm £0.75
 
1 turn around 10mm radius @ 1625nm £1.5
                       
  1. Optic Cable
    1. General Design
Optical fibers are housed in central loose tube that is made of high-modulus plastic and filled with waterproof compounds.
Polyethylene sheath is applied over the cable core.

3.2  Construction
      1. Cross Section of Cable  
Micro Duct Cable with HDPE Sheath Installation by Air Blowing Gcyfxty-2/4/6/8/12/24b6a1
      1. Dimensions and Descriptions of Cable Constructions
Item Contents Value
Fiber number 2 4 6 8 12 24
Loose tube diameter(±0.2mm) 2.0 3.0
Outer sheath Material HDPE HDPE
Color Black Black
Thickness(mm) Approx.0.3 Approx.0.3
Cable diameter(mm) Approx 2.5±0.1 3.7±0.1
Cable weight(kg/km) Approx. 5 11
      1. Mechanical Performance of Cable
Tensile performance(N) Crush(N/100mm)
Short term Long term Short term Long term
1.0G 0.5G 500 150
"G" is the weight of cable per kilometer, the unit is Newton  (N).
      1. Color Code of the Fiber
Each fiber can be identifiable throughout the length of the cable  in accordance with the following color sequence.  Fiber color in each tube starts from No. 1 Blue.
 
Fiber color code 12 fibers per tube 1 2 3 4 5 6
Blue Orange Green Brown Slate White
7 8 9 10 11 12
Red Black Yellow Purple Pink Aqua
24 fibers per tube 1 2 3 4 5 6
Blue Orange Green Brown Slate White
7 8 9 10 11 12
Red Black Yellow Purple Pink Aqua
13 14 15 16 17 18
Blue with black ring Orange with black ring Green with black ring Brown with black ring Slate with black ring White with black ring
19 20 21 22 23 24
Red with black ring Nature
 
Yellow with black ring Purple with black ring Pink with black ring Aqua with black ring
                       
Notes: No.13-24 fibers  with black  ring except the black fiber which is nature color in stead
 
      1. Color Code of the Loose Tube and Filler
The color of the tube will be  YELLOW.

 

3.3Mechanical, Electrical and Environmental Test Characteristics

The finished cables can be subjected to the following mechanical, electrical and environmental conditions.
Item Test Method Requirements
Tensile
performance
IEC 60794-1-2-E1
Load: 1.0G*W
Cable length under tension: Not less
than 50m.
Duration of load sustain: 1min.
Velocity of transfer device:
10mm/min
 
The maximum increase in attenuation less than 0.1 dB .
No change in attenuation after test at 1550nm.
Under visual examination without
magnification, no damage to the sheath or to the cable elements after test.
 
Crush IEC 60794-1-2-E3
Load: 500N
Duration of load: 1min
 
No change in attenuation after test at 1550nm.
Under visual examination without
magnification, no damage to the sheath or to the cable elements. The imprint of the striking surface on the sheath is not considered mechanical damage.
Bend IEC 60794-1-2-E11A
Mandrel radius: 10 times cable
diameter
Turns:10
Cycles:5
 
No change in attenuation at 1550nm after test.Under visual examination without magnification, no damage to the sheath or to the cable elements.
Repeated
bending
IEC 60794-1-2-E6
Bending radius: 20 times cable
diameter
Cycles: 25
Load: 25N
Duration of cycle: Approximately 2s.
No change in attenuation at 1550nm after test.
Under visual examination without
magnification, no damage to the sheath or to the cable elements.
 
Torsion IEC 60794-1-2-E7
Cycles:5
Length under test: 1m
Turns: 180°
Load: 1.0G*W
 
The variation on attenuation for each fiber less than 0.1dB at 1550nm
Under visual examination without
magnification, no damage to the sheath or to the cable elements.
No permanent change in attenuation after test
Temperature
cycling
IEC 60794-1-2-F1
Sample length: at least 1000m
Temperature range: -20ºC~+70ºC
Cycles: 2
Temperature cycling test dwell time:
12 hours
No change in attenuation coefficient at 1550nm after test.
 
Water
Penetration
IEC 60794-1-2-F5B
Time : 24 hours
Sample length : 3m
Water height : 1m
 
No water leakage
 
Compound flow IEC 60794-1-2-E14
Sample count:5
Sample length:300 +-5 mm,
Remove length: 130 +-2.5 mm,
Time:24h
 
No filling compound dripped.
 
Other parameters According to IEC 60794

Remark: "No attenuation changes" is considered as the attenuation changes 0.05 dB.
  1.  Cable Sheath Marking
Unless otherwise specified, the cable sheath marking shall be as follows:
  • Color: white
  • Contents: FCJ GROUP, the year of manufacture, the type of cable, length marking
  • Interval: 1m
  1. Packaging and Shipping
    1. Reel Length
Standard reel length: 2/4/6  km/reel
    1. Cable Drum
The cables are packed in  wooden drums
The minimum barrel diameter of the drum shall be more than 30 times of the nominal diameter for armored cable, and 25 times of the nominal diameter for unarmored cable.
    1. Labeling
The direction of rotation of the color scheme is shown by marking the clockwise and anti-clockwise ends with red and green adhesive tape respectively.
The markings are on both sides of the flanges as follows:
  • Cable Type/Size
  • Cable Length
  • Gross Weight.
  • FCJ GROUP.
  • Shipping mark.
    1. Cable Packing
Both cable ends are provided with protections against water penetration and  firmly secured to the drum, so the cable cannot move and the turns cannot slide when it is moved, handled or laid. the inner end has at least 3 meters of accessible length to perform reception tests in the cables.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now