Ngm Motor Start Capacitor for AC Electric Generator Run Sh

Type: Aluminum Electrolytic Capacitor
Application: AC / Motor, Air Conditioner, Fan
Packaging Type: Through Hole
Capacitance: 21UF to 1536UF
Structure: Fixed Capacitor
Manufacturing Material: Electrolytic
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
CD60
Electrolyte
Eletrolytic Paoer
Usage
AC Single-Phase Motors at 50/60Hz
Tuning
Eletrolytic Capacitor
Filter
Eletrolytic Capacitor
Materials of Case
Bakelite Plastic
Shape
Cylinder
Color
Black, Customizable
Terminal
Double Faston, Single Faston, Wires, Cable
Certifications
CQC, CE & RoHS, TUV & VDE, UL
Loading Port
Ningbo, Shanghai, Yiwu, Guangzhou
Package
50-100 Pieces Per Carton, Based on Capacitors Size
Packing Detail
Individual Box Is Available
Supply Ability
1, 200, 000 Piece/Pieces Per Month
Sampls
for Free (The Freight Shoule Be Paid by Custom)
H.S. Code
8532 2590
Delivery Time
15 - 30 Days (Based on Order Quantity)
Payment Term
T/T, L/C at Sight, Cash, Western Union
Shipment Term
Fob, CNF, CIF
MOQ
200 Pieces Per Type
Transport Package
Export Standard
Specification
IEC60252
Trademark
TOPO / oooneoo
Origin
China
HS Code
85322590
Production Capacity
1, 200, 000 Piece/Pieces Per Month

Product Description

CD60 (US) Series

Construction

  • Dielectric: aluminium foil & electrolyte paper
  • Bakelite plastic can

Features

  • High class insulating
  • High strength
  • Uneasy broken
  • Reliable and long in service life

Typical applications

  • Suitable for use in single phase A.C. motors

Terminals

  • Double Fast on
  • Cable
 
 
Technical data and specifications
Reference standards American ANSI /EIA -463
Operating temperature range 40-65 ºC
Rated capacitance CR 21 µF~1536 µF
Tolerance 0~+20%
Rated voltage VR 110VAC~330VAC
Rated frequency FR 50/60Hz
Dissipation factor tan δ tgδ< 0.10   tgδ< 0.15   (20ºC,100Hz)
Surge Volt between lugs Applying 1.25 times rated voltage for 2 seconds
Surge Volt between lug & case 2000VAC  10 seconds  non-broken down
Load Life According to the difference working voltage and capacitance, alternation 0.5 - 4 minute turn on
1 time for second,  12500 ~ 50000 times.
 
Dimensions (mm)
Capacitance (uF/MFD) 110VAC 125VAC 165VAC
Φ H Φ H Φ H
21-25 36.5 69.85 36.5 69.85 36.5 69.85
25-30 36.5 69.85 36.5 69.85 36.5 69.85
30-36 36.5 69.85 36.5 69.85 36.5 69.85
36-43 36.5 69.85 36.5 69.85 36.5 69.85
43-52 36.5 69.85 36.5 69.85 36.5 69.85
47-56 36.5 69.85 36.5 69.85 36.5 69.85
53-64 36.5 69.85 36.5 69.85 36.5 69.85
64-77 36.5 69.85 36.5 69.85 36.5 69.85
72-86 36.5 69.85 36.5 69.85 36.5 69.85
88-106 36.5 69.85 36.5 69.85 36.5 85.72
108-130 36.5 69.85 36.5 69.85 36.5 85.72
124-149 36.5 69.85 36.5 69.85 36.5 85.72
130-156 36.5 69.85 36.5 69.85 46.02 85.72
145-174 36.5 69.85 36.5 69.85 46.02 85.72
161-193 36.5 69.85 36.5 69.85 46.02 85.72
189-227 36.5 69.85 36.5 85.72 46.02 85.72
216-227 36.5 85.72 36.5 85.72 46.02 111.12
233-280 36.5 85.72 36.5 85.72 46.02 111.12
243-292 36.5 85.72 36.5 111.12 46.02 111.12
270-324 36.5 85.72 36.5 111.12 46.02 111.12
324-389 36.5 111.12 46.02 85.72 52.37 111.12
340-408 46.02 85.72 46.02 85.72 52.37 111.12
378-454 46.02 85.72 46.02 85.72 52.37 111.12
400-480 46.02 85.72 46.02 85.72 52.37 111.12
430-516 46.02 85.72 46.02 85.72 65.5 111.12
460-552 46.02 85.72 46.02 85.72 65.5 111.12
540-648 46.02 111.12 46.02 111.12 65.5 111.12
590-708 46.02 111.12 46.02 111.12 65.5 111.12
645-774 52.37 111.12 52.37 111.12 65.5 111.12
708-850 52.37 111.12 52.37 111.12 65.5 111.12
720-864 52.37 111.12 52.37 111.12 65.5 111.12
800-960 52.37 111.12 52.37 111.12 65.5 111.12
815-978 52.37 111.12 65.5 111.12 65.5 111.12
829-995 65.5 111.12 65.5 111.12 65.5 111.12
850-1020 65.5 111.12 65.5 111.12 65.5 111.12
1000-1200 65.5 111.12 65.5 111.12    
1020-1224 65.5 111.12 65.5 111.12    
1175-1410 65.5 111.12 65.5 111.12    
1280-1536 65.5 111.12        
Dimensions (mm)
Capacitance (uF/MFD) 220VAC 250VAC 330VAC
Φ H Φ H Φ H
21-25 36.5 69.85 36.5 69.85 36.5 85.72
25-30 36.5 69.85 36.5 69.85 36.5 85.72
30-36 36.5 69.85 36.5 85.72 46.02 85.72
36-43 36.5 69.85 36.5 85.72 46.02 85.72
43-52 36.5 85.72 36.5 85.72 46.02 85.72
47-56 36.5 85.72 36.5 85.72 46.02 85.72
53-64 36.5 85.72 46.02 85.72 46.02 111.12
64-77 46.02 85.72 46.02 85.72 46.02 111.12
72-86 46.02 85.72 46.02 85.72 46.02 111.12
88-106 46.02 85.72 46.02 111.12 52.37 111.12
108-130 46.02 85.72 46.02 111.12 65.5 111.12
124-149 46.02 111.12 46.02 111.12 65.5 111.12
130-156 46.02 111.12 46.02 111.12 65.5 111.12
145-174 52.37 111.12 52.37 111.12 65.5 111.12
161-193 52.37 111.12 52.37 111.12 65.5 111.12
189-227 52.37 111.12 65.5 111.12 65.5 111.12
216-227 65.5 111.12 65.5 111.12 65.5 111.12
233-280 65.5 111.12 65.5 111.12 65.5 111.12
243-292 65.5 111.12 65.5 111.12 65.5 111.12
270-324 65.5 111.12 65.5 111.12 65.5 111.12
324-389 65.5 111.12 65.5 111.12    
340-408 65.5 111.12 65.5 111.12    
378-454 65.5 111.12 65.5 111.12    
400-480 65.5 111.12 65.5 111.12    
430-516 65.5 111.12 65.5 111.12    
460-552            
540-648            
590-708            
645-774            
708-850            
720-864            
800-960            
815-978            
829-995            
850-1020            
1000-1200            
1020-1224            
1175-1410            
1280-1536            
Note: Can be manufactured according to customer's request.

Ngm Motor Start Capacitor for AC Electric Generator Run ShNgm Motor Start Capacitor for AC Electric Generator Run ShNgm Motor Start Capacitor for AC Electric Generator Run Sh

Capacitors Details:
Ngm Motor Start Capacitor for AC Electric Generator Run ShNgm Motor Start Capacitor for AC Electric Generator Run ShNgm Motor Start Capacitor for AC Electric Generator Run ShNgm Motor Start Capacitor for AC Electric Generator Run ShNgm Motor Start Capacitor for AC Electric Generator Run ShNgm Motor Start Capacitor for AC Electric Generator Run Sh
High-Return Solutions

Specifically to your satisfaction.

Most of our customers have been doing business with us for more than a decade, with full trust in our capabilities and reliability. We take pride in solving different challenges to customers in a productive way. Maybe you need a special collection, a distinct packing, an urgent delivery or any other supports, our team is here ready to offer you the integrated solutions and save you more.
Ngm Motor Start Capacitor for AC Electric Generator Run Sh

 

OEM and ODM

Contract manufacturing and housing molding for your brand.

Your brand and personal preferences could be custom on the products and packings. As a comprehensive capacitor manufactuer, Topo possesses the extensive custom design capabilities to meet your specific requirements, which help you to extend your brand's advantages.
Ngm Motor Start Capacitor for AC Electric Generator Run Sh

 

ECO Friendly and Full Material

Speaking of quality, green material is the very start. Topo only utilizes the materials friendly to the environment with a social responsibility perspective. Besides, great quality films make excellent capacitors. We never cut corners on materials, but apply full materials for each parts.
Ngm Motor Start Capacitor for AC Electric Generator Run Sh

 

Free Sample for Testing

An adequate amount of free samples could be offered for your testing of the important electrical parameters. From these aspects those prove that our products are of high quality and can stand the tests.

Rest assured and get your samples right away!


 

FAQs

Topo knows about your general concerns. Check the Q&A that will help you save time and worries in the first place. If your question is not listed, please contact us and we are happy to help.

Can the Topo capacitors be used in the AC and DC circuits?
Generally, our capacitors could apply with both circuits of AC and DC. Yet most of our products are for AC circuit purpose.
Are the Topo capacitors compliance products of EU CE and RoHS?
Yes. All of our capacitors comply with the CE, VDE, and RoHS standards.
Can I print my brand on the capacitor?
Absolutely. Topo has the capability of OEM and ODM. You are free to choose custom services or our regular high-standard capacitors.
How long does a quotation take?
In most cases, your enquiry will be answered within 24 hours. Rest assured that your enquiry will be taken seriously.
Can I get samples?
Sure. We offer adequate samples for your testing free of charge. However, the freight is not covered.


 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now