Ned-50 Multiple Output Switching Power Supply

Output Type: Multiple Output
Warranty: 2 Years
Output Power: 54W
Input Voltage: 85-264VAC /120-370VDC
Certification: CE
Brand: Elecal
Customization:
Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
NED-50
Frequency Range
47-63Hz
Transport Package
Carton
Specification
129*98*38mm(L*W*H)
Trademark
ELECAL
Origin
Wenzhou
Production Capacity
10000

Product Description

MODEL NED-50A NED-50B
OUTPUT OUTPUT NUMBER CH1 CH2 CH1 CH2
DC VOLTAGE 5V 12V 5V 24V
RATED CURRENT 6A 2A 4A 1.4A
CURRENT RANGE Nota.6 1-6A 0.3-3A 1-6A 0.2-2A
RATED POWER 54W 53.6W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 80mVp-p 200mVp-p
VOLTAGE AD J. RANGE CHI: 4.75-5.5V CH1:4.75 _ 5.5V
VOLTAGE TOLERANCE Not«.3 ±2.0% ±6.0% ±2.0% ±6.0%
LINE REGULATION Note.4 ±0.5% ±1.0% +0.5% ±1.0%
LOAD REGULATION Note.5 +1.5% +3.0% +1.5% +3.0%
SETUP, RISE TIME 500ms, 30ms/230VAC 1200ms,30ms/115VACatfull load
HOLD UP TIME (Typ.) 50ms/230VAC 10ms/115VAC at full load
INPUT VOLTAGE RANGE 85-264VAC 120-370VDC
FREQUENCY RANGE 47-63Hz
EFFICIENCY(Typ.) 79% 82%
AC CURRENT (TVp.) 1.1A/115VAC 0.65A/230VAC
INRUSH CURRENT (Typ.) COLD START 45A
LEAKAGE CURRENT <2mA/240VAC
PROTECTION OVERLOAD 110 -150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVERVOLTAGE CH1:5.75 _ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -20 - +60°C {Refer to "Derating Curve")
WORKING HUMIDITY 20 ^ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~+85°C, 10-95% RH
TEMP. COEFFICIENT ±0.03%/DC {0-45r)
VIBRATION 10 - 500Hz, 2G 10min./1cycle, period for 60min. each along Xf Y, Z axes
SAFETY &
EMC (Note 7}
SAFETY STANDARDS UL60950-1, CB(IEC60950-1) approved
WITHSTAND VOLTAGE l/P-0/P:3KVAC l/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE l/P-O/P, l/P-FG, O/P-FG:100M Ohms / 500VDC/25cC/ 70% RH
EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITY Complianceto ENSIOOIM-MAS,6,8,11, EN55024, EN61000-6-1, light indusiry level, criteria A
OTHERS MTBF 413.3Khrsmin. MIL-HDBK-217F {25.°
DIMENSION 129*98*38mm(L*W*H)
PACKING 0.44Kg; 45pcs/21 Kg/1.24CUFT
NOTE 1.All paraineters NOT specially mentioned are measured at 230VAC input, rated load and 25DC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacrtor.
3. Tolefance: Indudes set up tolerance, line regulation and load regulation.
4 Line regulation is measured from law line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power cant exceed rated csutput power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it sSII meets
EMC directives. For guidance on how to perform these EMC tests, please refer to ^EMI testing of component power supplies.1*
Ned-50 Multiple Output Switching Power SupplyNed-50 Multiple Output Switching Power SupplyNed-50 Multiple Output Switching Power SupplyNed-50 Multiple Output Switching Power SupplyNed-50 Multiple Output Switching Power SupplyNed-50 Multiple Output Switching Power Supply

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
10
Year of Establishment
2014-04-28