• Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
  • Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
  • Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
  • Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
  • Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
  • Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs

Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs pictures & photos
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
US $220 / Set
Min. Order: 1 Set
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Certifications
  • Company Profile
  • Packaging & Shipping
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
FLN
Arc-extinguishing Medium
SF6
Installation
Fixed
Structure
Sf6 Lbs
Poles Number
3
Type
Circuit Breaker
Function
Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
ISO9001-2000, CNAS
Rated Voltage
12kv, 24kv, 36kv
Rated Current
up to 1250A
Breaking Current
up to 31.5ka
Warranty
12 Months
Transport Package
Paper Carton
Specification
150/210/275mm
Trademark
USUNE
Origin
China
HS Code
8535210000
Production Capacity
5000 Sets/Week

Packaging & Delivery

Package Size
100.00cm * 50.00cm * 50.00cm
Package Gross Weight
100.000kg

Product Description

 
Product Medium voltage SF6 load breaker switch
Rated voltage 12KV, 24KV, 36KV
Rated current up to 1250A
Breaking current up to 31.5KA
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch LbsMedium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch LbsMedium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
 
Product Description

FL(R)N36-12(D) Load switches and combiners (hereinafter referred to as "load switches" and "combiners") are suitable for three-phase ac power systems of 10kV and 50Hz. This product as industrial and mining enterprises, high-rise buildings, residential quarters, pre-installed type substation, for the breaking, closing load current, the fault current, control and protection circuit and the power distribution transformer.

Normal operating conditions

a)Ambient air temperature is not more than 40 ºC, and at 24 h closed to the average no more than 35 ºC. Minimum ambient air temperature 25 ºC.
b)The effects of sunlight can be ignored
c)No more than 3000m above sea level.
d)Ambient air is not significantly contaminated by dust, smoke, corrosive and/or flammable gases, vapors, or salt fog. If the user does not have special requirements, the manufacturer may consider that these situations do not exist.e)The humidity conditions are as follows:
--The average relative humidity measured within 24h is no more than 95%.
--The mean value of water vapor pressure measured within 24h shall not exceed 2.2kPa.
--The average monthly relative humidity should not exceed 90%.
--The average monthly water vapor pressure does not exceed 1.8kpa. In such conditions appear condensation occasionally.
e) The vibration or ground motion from the outside of the switching equipment and the control equipment has no obvious relationship with the normal operation mode of the equipment. If the user has no special requirements, the manufacturer may not consider these situations.

GB 3804-2004         3.6KV~40.5KVHigh voltage ac load switch
GB 16926-2009        High voltage ac load switch fuse combination electrical appliance
GB 11023-1989        Test guide for fln36 gas seal of high pressure switching equipment
GB 1985-2004         High voltage ac isolation switch and ground switch
GB/T 11022-2011 Common technical requirements for high voltage switching equipment and control equipment standards

Item NO. Name Unit Technical parameters
Load break switch panel
1 Rated Voltage Un kV 12 24 36
2 Rated Frequency Hz 50 50 50
3 Rated Current A 630 630 630
4 Rated Load Breaking Current A 630 630 630
5 Rated Short Time Withstand Current(rms) kA 20 20 20
6 Rated Short Time Duration s 3 3 3
7 Rated Peak Withstand Current  kA 50 50 50
8 Rated Closed Switch - Off Current A 630 630 630
9 Rated Cable Charging Breaking Current A 10 10 10
10 Rated Active Load Breaking Current A 630 630 630
13 Earthing Switch 2s Short Time Withstand Current  kA 20 20 20
14 Rated Short-Circuit Current Making Times  times 2 2 2
15 Rated Current Breaking Times times 10 10 10
16 Mechanical Endurance  Load Break Switch times 3000 3000 3000
Earthing Switch times 2000 2000 2000
17 SF6 gas anual leakage rate≤   /year 0.10% 0.10% 0.10%
18 Rated Insulation Level Unit Technical parameters
1min Power Frequency withstand voltage(rms) On isolating distance kV 48 60 110
Phase to Phase  kV 42 50 85
Phase to Earth kV 42 50 85
Lightning impulse withstand voltage(peak) On isolating distance kV 85 145 215
Phase to Phase  kV 75 125 185
Phase to Earth kV 75 125 185

 

Product Parameters

Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch LbsMedium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch LbsMedium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs

 

Detailed Photos

Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch LbsMedium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch LbsMedium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch LbsMedium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
 

Certifications

Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs

Company Profile

Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs

Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch LbsMedium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch LbsMedium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs

Packaging & Shipping
 
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
 
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs

 

Our Advantages

1. R&D Ability

We are specialized in the field for more than 10 years, and has a well experienced R&D team taking the design and development work for each project based on customer's special demands.
 
2. QC Team
We have extremely strict QC procedure from components to finished products.
 
3. Production Capacity
Steady production period within 15 days.
 
4. High Quality Product
We have full set of test reports for products and are supplying for the world's largest utility - State Grid Corporation of China(SGCC) and China Railway Construction Group.
 
FAQ

Q1: Are you factory or trading company?

A: Factory, we can guarantee our price is reasonable and competitive.
 
Q2: When can I have the price?
A: Usually we quote within 24 hours after receiving your inquiry.
 
Q3: How could I get a sample?
A: If you can not buy our product in your local area, we will ship a sample to you. You will be charged of sample price plus all related shipping costs.

Q4: Can we print our logo and company name on products?
A: Yes, of course, we accept OEM.
 
Q5: What is the lead time?
A: The lead time depends on the quantities ordered, normally within 7-20 days after receiving the payment.
 
Q6: How's your quality control process?
A: All products will be inspected starting from accessories, and will be carried out with routine tests before leaving
our factory.
 
Q7: How to solve the quality problems after sales?
A: Take photos or video of the quality problems and send to us for our checking and confirming, and we will make a satisfied solution for you within 1-3 days.
 
Q8: What's the warranty time?
A: 12 months from shipping date.

Q9: Why choose us?
A:1.We are specialized in the field for more than 10 years, and has a well experienced R&D team taking the design and development work for each project based on customer's special demands.
2.We have extremely strict QC procedure from components to finished products.
3.Steady production period within 15 days.
4.We have full set of test reports for products and are supplying for the world's largest utility - State Grid Corporation of
China(SGCC)
and China Railway Construction Group.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs pictures & photos
Medium Voltage Switchgear Ring Main Unit Sf6 Load Break Switch Lbs
US $220 / Set
Min. Order: 1 Set
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
22
Year of Establishment
2011-11-29