• Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter
  • Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter
  • Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter
  • Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter
  • Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter
  • Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter

Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter

Type: Catheter
Material: High Quality PC Material, PU Material
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Quality Guarantee Period: 5 Years
Group: Children
Logo Printing: with or Without Logo Printing
Samples:
US$ 3.1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
5FR, 6FR, 7FR, 8FR, 10FR, 12FR
Sample of Product
Free for 2PCS
Brand Name
MCR/OEM
Relative Type
24h/72h/Child/Adult
Certificates
CE/ ISO13485/ Cfda
Classification
Class II
Package
1PCS/Pouch, 10 Pouches/Box, 10 Boxes/Carton
Delivery Time
30 Days
Color
Transparent
Transport Package
Carton
Specification
5FR, 6FR, 7FR, 8FR, 10FR, 12FR
Trademark
MCR
Origin
China
HS Code
901839
Production Capacity
100, 000PCS/Month

Product Description

Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter
Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter
- It is designed with a protective sleeve to isolate the germs inside and help caregivers avoid cross-infection.

-Simultaneously ventilation design will allow the patients comfort of suctioning without stopping the air ventilation.


Feature

- Continuous Breathing
  Simultaneously ventilation

- Soft Blue Suction Tip
This design reduces damage to the patient while suctioning.
After returning the catheter, the tip of the tube is easier for irrigational cleaning.

- Y Connector Type
ET "Y" neonatal and pediatric care adapters are available for 5, 6, 7, 8, French sizes closed suction catheter.

- Disconnecting Wedge
Designed to equip the wedge with both disconnecting and clipping functions

- For Endotracheal Tube and Tracheostomy Tube
Designed for endotracheal and tracheostomy tube using
Tubes with different length are available

- Prevent Cross Infection
Designed with a protective sleeve to isolate the bacteria inside and help caregivers avoid cross-inflection.

-Irrigation Port with Non-Return Valve
The non-return valve prevents backflow leakage during washing and aerosolized secretion contamination.




Product Data Sheet
                      
 Clour Size Products' Specification & Description Tube OD   Length of Tube Product Code
Grey Neonatal/24H "Y" Endotracheal Tube Adapter (2mm, 2.5mm, 3.0mm) 5Fr (1.7mm) 300mm MC-02440
Light Green Neonatal/24H "Y" Endotracheal Tube Adapter (2.5mm,3mm,3.5mm) 6Fr (1.95mm)  300mm MC-02441
Ivory Pediatric/24H "Y" Endotracheal Tube Adapter (2.5mm, 3mm, 3.5mm) 7Fr (2.3mm) 300mm MC-02442
Light Blue Pediatric/24H "Y" Endotracheal Tube Adapter (3mm, 3.5mm, 4mm) 8Fr (2.7mm) 300mm MC-02443
Black Pediatric & Child/24H "Y" Endotracheal Tube Adapter (4.5mm, 5mm, 5.5mm) 10Fr (3.35mm) 400mm MC-02444
White Big Child/24H "Y" Endotracheal Tube Adapter (5.5mm, 6mm, 6.5mm) 12Fr (4.05mm) 400mm MC-02445

We can produce the closed suction catheter according to customers' requirements!!!


-Instructions for Use

*Set up Procedure
1. Inspect the product before use. Do not use it if the package is not intact.

2. Open the sealed package and remove the product.

3. Connect the Endotracheal Tube/Tracheostomy Tube to the Revolvable adapter.

4. Connect ventilator tube to the Revolvable Ventilator Connector.

5. Attach the date label to the color ring.

6. Before suctioning commences ensure that the cap of the MDI Port
Irrigation Port is closed.

7.Before suctioning: Please ensure that the on-off valve is in the open position. Simply slide the on-off valve to a position which allows the catheter to enter the Endotracheal tube/Tracheostomy tube.

*Suctioning Procedure

Caution-always use the recommended vacuum levels./Consider length of suctioning time
                 
1. Grip the three-way adaptor in one hand and use the other hand to feed the suction catheter into the Endotracheal tube/Tracheostomy tube, to the required depth.
 Depth markers can be visible through the protective cover for your guidance.

2. Once the suction catheter is in the desired position /depth, depress the vacuum
control valve to begin suctioning.

3. Remove the suction catheter until the protective sleeve is straight.

4. Repeat steps 1-3 as necessary.

Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter

Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction CatheterDisposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter
Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction CatheterDisposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter

Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter

Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter

Disposable Medical Consumables Closed Suction System Child Type 24h for Neonatal, Pediatric and Child Closed Suction Catheter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now