• Mdbts-30V60A Battery Multifunctional Tester Battery Detection System
  • Mdbts-30V60A Battery Multifunctional Tester Battery Detection System
  • Mdbts-30V60A Battery Multifunctional Tester Battery Detection System
  • Mdbts-30V60A Battery Multifunctional Tester Battery Detection System

Mdbts-30V60A Battery Multifunctional Tester Battery Detection System

After-sales Service: 1 Year
Warranty: 1 Year
Trademark: minder-hightech
Origin: Guangzhou
Diamond Member Since 2017

Suppliers with verified business licenses

Basic Info.

Model NO.
MDBTS-30V60A
HS Code
8015809090
Production Capacity
200PCS/Yearpcs/Year

Product Description

Battery multifunctional testing system
MDBTS-30V60A battery multifunctional tester
  • Product description: MDBTS-30V60A battery multifunctional tester
  • Mdbts-30V60A Battery Multifunctional Tester Battery Detection System
MDBTS-30V60A battery multifunctional tester
Advantages and characteristics:

Single point is independent, can be carried out for each battery test channel
Independent charging and discharging process settings.
The equipment accuracy is 0.05%, and the data recording time is 1 second/time,
The fastest is 0.1 second/time, and the stability is high.
The software has powerful functions and friendly man-machine interface.
Four-wire system test interface to ensure high measurement accuracy.
Modular design concept, easy to maintain.

Mdbts-30V60A Battery Multifunctional Tester Battery Detection System
Test fuction:
1,Cycle life testing.
2,Charge and discharge characteristic test.
3,SOC maintain ability testing.
4,Overcharge and over-discharge rate affordability test.
5,voltage test.
6,temperature test.
7,maganification test.
8,Dynamic and static SOC test.
Device model MDBTS-30V60A Single channel
Output power
15W communication method TCP/IP (Network port)
Discharge voltage 30V-0.8V Charging voltage DC0-30V data record 100mS~65535 S
Recharging current 30Vseries:0.02A~60A Discharge current 30Vseries:0.02A~60A
Current accuracy ±(0.05%RD+0.05%FS) Voltage accuracy ±(0.05%RD+0.05%FS)
Voltage resolution The smallest unit used by 1MV equipment when detecting or setting voltage
Electric current resolution The smallest unit used by 1MV equipment when detecting or setting voltage
Charging mode Constant current charging, constant voltage charging, constant power charging
Discharge mode Constant current discharge, constant power discharge
Charging cut-off
condition
Voltage,current,time, capacity,temperature Discharge cut-off
condition
Voltage,current,time,capacity,temperature

Mdbts-30V60A Battery Multifunctional Tester Battery Detection System30V60A battery testing equipment
Mainly used for:soft pack polymer battery Cylindrical battery
The star product in the 3C tester, with high response, high precision, high sampling and other performance characteristics, simple structure and modularization
A single test device is designed for 8 channels, each Channel independent programming, and supports 254 working steps at most, and the time error of the working steps does not exceed 50ms.
Test mode support:
Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging. Constant current discharge, constant power discharge.
  
Input power AC220±10%/50Hz(Cabinet power supply mode: three-phase five-wire)
Main temperature 1 channel per channel can be selected according to the specific equipment
input resistance ≥10MQ
Current response time Current rise time≤50mS Power accuracy ±(0.05%RD+0.05%FS)
Number of steps in a single cycle ≤100step,With nested loop function
Circuit configuration Modular structure design, easy replacement and maintenance
VCELL,TCELL Optional auxiliary temperature, auxiliary voltage, single module 8 channels, can be arbitrarily mapped to each main channel Temperature range: -40~140°(Voltage range: 0~5V/0~20V)
 
performance index parameter
Input power AC220V ±10%/50Hz

Voltage
Measuring range 0.75~30V
Output range 10mV~30V
Precision ±0.1%*FSR
Output accuracy ±0.1%*FSR

Current
Measuring range 0~60A
Output range 50mA~20A
Measurement accuracy ±0.1%*FSR
Output accuracy ±0.1%*FSR

Power
Measuring range 0~900W
Output range 0~900W
Measurement accuracy ±0.2%*FSR
Output accuracy ±0.2%*FSR

Data probability
Sampling rate 1HZ:1 samples/sec
Recording rate 1HZ:1 point/sec
Recording conditions TIVtemp
Full-scale current response time ≤30ms
Time resolution 1s
input resistance ≥1MOhm
Support charge and discharge type Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant load discharging, constant power discharging, support channel paralleling
Number of test commands 399 commands can be set, 65535 loops can be set, 5 levels of nested loops are supported
communication method Ethernet,100Mbps
safety protection hardware Add anti-reverse connection module to prevent battery reverse connection
software 1 Power-down data protection
2Support the setting of protection conditions: voltage upper limit, voltage lower limit, current upper limit, current lower limit, capacity upper limit, energy upper limit, voltage change rate, delay protection, temperature upper limit, temperature lower limit
Calibration frequency ≥1year
Fan noise ≤85db
Number of channels per chassis 8aisles

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now