• Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence
  • Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence
  • Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence
  • Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence
  • Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence
  • Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence

Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence

After-sales Service: Lifetime Technical Support
Warranty: One Year Free Parts
Customized: Customized
Structure: Desktop
Material: Stainless Steel
Certification: CE, ISO
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Related products
  • Product Parameters
  • Main Structure
  • Exhibition Photos
  • Company Profile
  • After Sales Service
Overview

Basic Info.

Model NO.
GD-5453
Application
School, Hospital, Lab
Type
Measurement Type
Product Name
Sulfur Content Tester
Color
Grey
Sample Types
Solid, Gas and Liquid
Standard
ASTM D5453
Lead Time
to Be Negotiated
to Be Negotiated
Ultraviolet Fluorescence Method (S)
Ultraviolet Fluorescence Method (S)
Solid: 1-90mg; Liquid: 2-50μl; Gas: 1-50ml
Measuring Range
0.1~10000mg/L (High Concentration Should Be Dilute
Temperature Range
Room Temp~1300 Degree
Weight
Host: 20kg; Temp Controller: 40kg
Transport Package
Wooden Case for Total Sulfur Content in Coal Anal
Specification
Host: 305(W)*460(D)*440(H)mm
Trademark
GOLD
Origin
China
HS Code
9031809090
Production Capacity
100 Sets/ Month

Product Description

Laboratory Analysis Instrument of Sulfur Content Analysis By UV-fluorescence

Product Description

When the sample was blown into the pyrolysis furnace by carrier gas and after oxidative decomposition, the sulfur converted intoS02 quantitative. Reaction gas enter into the fluorescence chamber after dehydrate by membrane dryer. In the fluorescence chamber, part of the SO2 converted into excited state S02 after irradiate by UV. (S02*). Emitting photons when the S02*transitions to ground state. Optical signal received and to amplify by the PMT and then change optical signals into electrical signals. Then amplified by the amplifier and input computer for data processing. That can be converted to electrical signal which proportional to light intensity.
 
Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence

Related products

Sulfur Content Tester Selection List:

Parameter GD-380B GD-387 GD-17040 GD-0689
Standards GB/T 380, ASTM D1266 GB/T 387, ASTM D1551 GB/T 17040, GB/T11140, ASTM D4294 ISO 20846,ASTM D5453,ASTM D4629,ASTM D5762, ASTM D6069
Test sample Light oils, such as gasoline, kerosene Dark oils which sulfur content >0.1% Petroleum oil with sulfur content of 20ppm  to 100% Petroleum oil with sulfur content of 5ppm to 100%
Test method Lamp method Quartz tube method X-ray fluorescence (XRF)method Ultraviolet fluorescence method
Dimension 3800*320*600mm 530*400*670mm 468*368*136mm Host:305*460*440mm
Temp controller:550*460*440mm
Working temperature 5~40ºC 5~40ºC 5~40ºC 5~40ºC
Relative humidity ≤85%(30ºC) ≤85%(30ºC) ≤85%(30ºC) ≤85%(30ºC)
Power suply AC220V ±20V, 50Hz AC220V ±20V, 50Hz AC220V ±20V, 50Hz AC220V ±20V, 50Hz

Applicable ranges of the common analytical techniques:
Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence
Various analytical techniques have been developed for the determination of sulphur in different industrial environments. Gas chromatography (GC), chemiluminescence detector (CLD), ultraviolet fluorescence (UVF), diode array spectroscopy (DAS), X-ray fluorescence (XRF), dry colorimetric detector (DCD) or Sensi-Tape technology, and tunable diode laser absorption spectroscopy (TDLAS).

Analysis of the cause of the failure :
1. After starting up, the furnace temperature display is abnormal, the temperature does not rise, or the temperature rises continuously. Generally, there are four reasons. One is that the power of the host is not turned on. The other is that the thermocouple is short-circuited. The third is that the fixed relay is broken. The fourth is that the temperature control part is dead.
2. The fan does not turn after the machine is turned on. This may be related to the ground wire, or there is a problem with the fan itself.
3. After the sample is injected, the machine has no model. Generally, there are 5 reasons, one is that the zinc lamp is not turned on, the other is that the photomultiplier tube has no high pressure, the third is air leakage at the gas circuit end, the fourth is insufficient gas flow, and the fifth is the photomultiplier tube Chances are it's broken.
4. There are generally three reasons for the decrease in the integral fraction of known standard samples analyzed with the same sample volume. One may be that the reaction chamber is dirty, the other may be that the light intensity is not enough, and the third may be air leakage.

Product Parameters

Sample types: Solid, Gas and Liquid
Method of determination: Ultraviolet fluorescence method (S)
Sample injection quantity: Solid: 1-90mg; Liquid: 2-50μL; Gas: 1-50mL
Measuring range: 0.1~10000mg/L (High concentration should be diluted)              
Measuring accuracy:

Concentration values (ppm) Injection quantity (µL)  RSD (%)
0.2 20 25
5 10 10
50 10 5
100 10 3
5000 10 3

Temperature range: room temp~1300ºC
Temperature-controlled precision: ±1ºC
Sample detection time: about 2 minutes
Gas source requirements: High-purity argon: above 99.9%
                                               High purity oxygen: above 99.9%
Power supply: AC220V±22V, 50Hz±0.5Hz, 1500 W
Dimension: Host: 305(W)×460(D)×440(H)mm Temp controller: 550(W)×460(D)×440(H)mm
Weight: Host: 20kg; Temp controller: 40kg

Main Structure

 

Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence

Exhibition Photos

 

Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence

Company Profile

About us:

Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd is a high-tech enterprise for researching, designing, developing and producing scientific and measuring instruments. With its continuous drawing of lessonas, unremitting innovation and borrowing of advanced technology from both at home and abroad, our company is now becoming a professional manufacture of oil tester,laboratory instrument,road building instrument. 
Laboratory Analysis Instrument of Sulfur Content Analysis by UV-Fluorescence

After Sales Service

Service
Device Problem Handling Social media 24 hours online communication
Mail Seamless Docking
Video Conferencing
Laboratory Analysis Instrument of Sulfur Content Analysis by UV-FluorescenceAny questions about Laboratory Analysis Instrument of Sulfur Content Analysis By UV-fluorescence, please contact me without hesitation, welcome your inquiry!Price can be negotiated !
Hope that it will bring convenience to your work and accompany you on the road to success.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters