• for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer
  • for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer
  • for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer
  • for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer
  • for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer
  • for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer

for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer

After-sales Service: 1year
Application: Industrial
Warranty: > 1Year
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer pictures & photos
for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer
US $58,190 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • One-stop Shopping
  • Certifications
  • Company Profile
  • Factory
  • Exhibition
  • FAQ
Overview

Basic Info.

Model NO.
ICP-6800
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
New Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Customized
Working Temperature
15ºC-30ºC
Power Supply
220±10V 50-60MHz
Working Humidity
≤70%
Frequency Stability
<0.1%
Transport Package
Wood
Specification
480*350*220mm
Trademark
Macy
Origin
China
HS Code
9027300000
Production Capacity
5000

Packaging & Delivery

Package Size
180.00cm * 80.00cm * 85.00cm
Package Gross Weight
300.000kg

Product Description

for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer

Product Description

 

for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer

Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.

At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.


 

Product Parameters

 

Application Environment

CONTENT RANGE

Shipping/Storage Ambient Temperature 15ºC-25ºC

Shipping/Storage Relative Humidity ≤70%

Atmospheric pressure 86-106 kPa

Power Supply 220±10V 50-60MHz

Working Humidity ≤70%

Working Temperature 15ºC-30ºC

 

RFPower technical parameter:

Circuit type: solid-state RF power supply, with function of automatch

Frequency: 27.12MHz±0.05%

Frequency Stability: <0.1%

Power Output: 800W-1200W

Power Output Stability: <0.3%

Escaped RF radiation: 30cm away from the instrument, electric field: E<2V/m

 

Sampling System Technical Parameter:

Output working coil inner diameter :25mm

Torque tube: Three concentric, external diameter 20mm

Coaxial nebulizer:Outer diameter 6mm

Double barrel atomizing chamber: Outer diameter 34mm

 

Gas Flow Controls

1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min)

2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min)

3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)

4. Pressure Maintaining Valve(0-0.4MPa)

5. Cooling Water:Temperature: 20-25ºC, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa

 

Spectrometer

Optics:Czerny-Turner type

Focal length: 1000 mm

Grating: Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

Reciprocal linear dispersion: 0.26nm/mm

Resolution:≤ 0.007nm (3600 line grating);≤0.015nm (2400line grating)

 

Element WL(nm) Limit   Element WL(nm) Limit
La 408.672 <3.0   Cr 267.716 <5.0
Ce 413.765 <5.0   Al 396.152 <5.0
Pr 414.311 <5.0   Zr 343.823 <5.0
Nd 401.225 <5.0   Ag 328.068 <3.0
Sm 360.946 <10.0   Sr 407.771 <1.0
Eu 381.967 <1.0   Au 242.795 <5.0
Gd 342.247 <10.0   Pt 265.945 <5.0
Tb 350.917 <3.0   Pd 340.458 <5.0
Dy 353.170 <3.0   Ir 224.268 <10.0
Ho 345.600 <3.0   Rh 343.489 <10.0
Er 337.271 <3.0   Ru 240.272 <5.0
Tm 313.126 <3.0   Ba 455.403 <1.0
Yb 369.419 <1.0   As 228.812 ≤15
Lu 261.541 <3.0   Sb 206.833 ≤15
Y 371.030 <1.0   Bi 223.061 ≤10
Sc 335.373 <1.0   Hg 253.652 ≤15
Ta 226.230 <5.0   Pb 220.353 ≤15
Nb 313.340 <5.0   Ga 294.364 ≤10
Mn 257.610 <3.0   Se 203.985 ≤10
Mg 279.553 <1.0   Sn 242.949 ≤20
B 249.773 <10.0   Te 214.281 ≤10
Zn 213.856 <3.0   Ta 226.230 ≤5.0
Co 228.616 <3.0   Th 283.730 ≤10
Si 251.611 <10.0   Tl 276.787 ≤30
Ni 232.003 <5.0   Re 227.525 ≤5
Cd 226.502 <3.0   Ge 209.426 ≤15
Fe 239.562 <3.0   Os 225.585 ≤1
Ca 393.366 <1.0   W 207.911 ≤10
Mo 281.615 <5.0   Cu 324.754 <3.0
V 310.230 <5.0   Li 670.784 ≤3
Be 313.041 <1.0   Na 588.995 ≤20
Ti 334.941 <3.0   K 766.490 ≤60


 

Wavelength range: 3600 line grating:(190nm~500) nm;2400 line grating: (190nm~800) nm

Minimum pace of stepping motor: ≤0.0006 nm

Exit Slit:12μm;Entrance Slit:10μm

 

Photoelectric Converter Performance

Photomultiplier tube specification: R293/R928

Negative HV on PMT: 0-1000V;Stability: <0.05%

 

Overall Performance

Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):

 

for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer

 

 

One-stop Shopping

 

for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometerfor Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometerfor Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometerfor Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometerfor Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer

Certifications

 

for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer

Company Profile

 

for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer
Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.

 

 

Factory
for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer
Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.
Exhibition

for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer

FAQ

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer pictures & photos
for Heavy Metal-Analysis Instrument Nductively Coupled Plasma Emission Spectrometer
US $58,190 / Piece
Min. Order: 1 Piece
Gold Member Since 2021

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Registered Capital
2.96 Million USD
Management System Certification
ISO 9001, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, GMP