Num | Displays | Fault | Checklist |
TCOPEN | Thermocouple open | Use digital multimeter to check if thermocouple line is open or connect well | |
TCBAD | Heater line & tc line swapped | Check if heater line & tc line swapped | |
TCREV | Thermocouple inverted | Connect thermocouple line again | |
SCRBAD | Triac bad | Use digital multimeter to check if triac is bad | |
PVERR | input power error | Check if input power line connect wrong | |
OUTBRK | Output open | Check if the heater line is open or not connected with the multimeter to check whether the fuse is damaged | |
OUTSRT | Output shorten | Check if the heater line is extruded |
Features: | |
1 | Unique self-tuning control by AST |
2 | Touch screen, easy operation |
3 | Automatic, manual and standby mode |
4 | 2 set point values(Active and Standby) |
5 | Automatic detection of thermocouple and heating device |
6 | Alarm on thermocouple faults(open / inverted) |
7 | Heater broken alarm (open/shorten) |
8 | Alarm on heater and thermocouple inverted |
9 | Selectable soft start mode |
10 | Current of heating elements measurement |
11 | Alarm on temperature deviation(High and Low) |
12 | ºC and ºF |
13 | Language interface: English and Chinese |
Num | Menu | Setting value |
1 | Thermocouple Type(SENS) | J |
2 | Temperature Unit(C-F) | °C |
3 | Standby temperature(Standby) | 100°C |
4 | Output mode(Out) | PIDD |
5 | High temperature alarming(AL-H) | 30°C |
6 | Low temperature alarming (AL-L) | -30°C |
7 | Soft start(SOFT) | ON |
8 | Soft start time (SOFT-T) | 4 Min |
9 | Working temperature set value | 120°C |
10 | System language(Language) | English |