Basic Info.

Model NO.
ZNCL-B
Material
Ceramic
Type
Hot Plate
Name of Commodity
Magnetic Stirring Hot Plate
Model
Zncl-B
Heating Plate Size
230X230mm
Speed Adjust Range
50-2000r/No Polar Adjust
Motor Power
40W
Accuracy of Temp Control
+-1 Degree C
Temperature Range
Rt-380 Degree C
Over-Temp Protection
390 Degree C Automatic Protection
Heating Power
800W
Material of Heating Plate
Aluminum Alloy+Cloisonne Coating
Stirrer Volume
50-3000ml Beaker
Heating Volume
50-3000ml Beaker
Overall Dimensions
430X270X150mm
Packing Dimensions
480X320X200mm
Weight
6000g
Transport Package
Plywood Box
Specification
480x320x200mm
Trademark
WollenLab
Origin
China
HS Code
8479820090
Production Capacity
1000sets/Month

Product Description

High Temperature Automatic Stirring And Heating Mechanical Magnetic Stirrer For Lab 
 

Features:
 
1. The heating plate adopts the square aluminum alloy material+special coating panel, which is beautiful and anti-corrosion.
2. The maximum surface temperature can reach 350ºC.
3. Digital speed display function.
4. The temperature control adopts fuzzy PID control algorithm, dual-screen digital display, self-tuning function, with high measurement accuracy, low temperature flushing, single-key touch operation, internal and external galvanic temperature measurement, thyristor control output, 160-240V wide voltage Power supply, with burnout protection function.
5. Heat and stir 50-10000ml standard or non-standard reaction flask.
6. Adopt German PAPST series brushless DC motor, stable performance, low noise, long life, no sparks.
7. The shell adopts one-time molding flame-retardant reinforced PBT injection shell, high temperature resistance, corrosion resistance, and good insulation performance.
8. 30° inclined control panel suitable for sitting and standing viewing angles.
9. Stepless speed regulation, stable low speed, strong high speed.
High Temperature Automatic Stirring and Heating Mechanical Magnetic Stirrer for Lab
Model ZNCL-B ZNCL-BS
Heating Plate Size 140x140mm 180x180mm 230x230mm 280x280mm
Power Supply 220V/50Hz
Speed Adjust Range 50-2000r/min no polar adjust 50-2000r/min digital display
Motor Power 40W
Accuracy of Temp Control ±1ºC
Temperature Range RT-380ºC
Over-temp Protection 390ºC automatic protection
Heating Power 350W 500W 800W 1200W
Material of Heating Plate aluminum alloy + cloisonne coating
Stirrer/Heating Volume 50-500ml beaker 50-2000ml beaker 50-3000ml beaker 50-5000ml beaker
Overall Dimensions 325x215x120mm 325x215x120mm 430x270x150mm 500x330x150mm
Packing Dimensions 375x265x170mm 375x265x170mm 480x320x200mm 550x380x200mm
Net Weight 3200±200g 4500±200g 6000±200g 7500±200g
Working Time continuous
High Temperature Automatic Stirring and Heating Mechanical Magnetic Stirrer for Lab
Precautions:
 
1. Do not use dry boil.
2. Please do not connect the ground wire to ensure safe use.
3. In order to extend the using of the product, all magnetic stirring motors are equipped with fan of heat dissipation function, so when you doing heating experiments, especially high temperature heating tests, the instrument cannot be used for heating alone. Be sure to adjust the motor to rotating or middle Speed rotation state (or idling) to prevent the motor and electrical appliances from being damaged by high temperature radiation. If the motor cannot start to rotate, contact for maintenance in time.
4. When the high-temperature heating is finished, please turn off the heating first, wait a few minutes for the residual temperature to dissipate, and then turn off the stirring.
5. The heating part has a high temperature, so be careful when working to avoid burns.
6. If there are wet hands, liquid spills, or long-term exposure to excessive humidity, the leakage phenomenon should be dried in time or dried naturally before use to avoid danger.
7. When it don't use for a long time, please store it in a dry place without corrosive gas.
8. When the ambient humidity is relatively high, induction electricity may be transmitted to the shell through the insulation layer. Please connect the ground wire to avoid leakage and pay attention to ventilation.
9. Relative humidity: 35%-85% (no condensation).
High Temperature Automatic Stirring and Heating Mechanical Magnetic Stirrer for Lab
High Temperature Automatic Stirring and Heating Mechanical Magnetic Stirrer for Lab
High Temperature Automatic Stirring and Heating Mechanical Magnetic Stirrer for Lab

Our Services:

High Temperature Automatic Stirring and Heating Mechanical Magnetic Stirrer for Lab
High Temperature Automatic Stirring and Heating Mechanical Magnetic Stirrer for Lab

 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now