High Efficient Axial Fan ECI Motor

Application: Universal, Industrial
Operating Speed: Adjust Speed
Magnetic Structure: Permanent Magnet
Function: Driving, Control
Certification: CCC, ISO9001
Brand: DBS
Samples:
US$ 300/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Jiangsu, China
Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 5 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
to see all verified strength labels (23)

Basic Info.

Transport Package
Export Standard Package
Specification
0.5kw-15kw
Trademark
DBS
Origin
China
HS Code
8501109990
Production Capacity
150 Units Per Day

Product Description

High Efficient Axial fan ECI Motor 
High Efficient Axial Fan ECI Motor

Product Brief
E-MAX motor is the special designed permanent magnet synchronous motor based on the IEC norm. E-MAX PMSM will be used for next generation which need more energy saving product. Exceed IE4 variable speed AC motor (IEC60034-30-2-2016).

E-MAX motor is the first generation of DBS EC motor. E-MAX has led to develop the next generation of technology in motor efficiency and performance.
E-MAX motor contain two series:
E-Max commercial
IEC Frame 71 to 90 permanent magnet synchronous motor integrated drive
E-Max Industrial
IEC Frame 71 to 132 permanent magnet synchronous motor

E-Max Commercial series (ECI series)

Model Frame Rated Output Output Maximum
size torque @1500rpm @3000rpm speed
  (Nm)** (kW) (kW) (rpm)
T71ECI01X36 71 1.2 0.2 0.41 3600
T71ECI02X36 2.4 0.41 0.82 3000
T71ECI03X18 3.2 0.55 - 1800
T90ECI03X36 90 3.2 0.55 1.1 3600
T90ECI05X30 4.8 0.75 1.5 3000
T90ECI07X18 7 1.1 - 1800

High Efficient Axial Fan ECI Motor
** The rated torque is based on the motor cooling method. The detail torque please see data sheet.
E-Max Commercial Motor Drive Function
CW/CCW chooseStart-stop terminal0-10VDC speed controlRS485 ModbusSpeed hand control by adjustable resistanceSpeed feedback

E-Max Industrial series (EC series)
Model Frame Rated Output Output Maximum
size torque @15000rpm @3000rpm speed
  (Nm)** (kW) (kW) (rpm)
T71EC01X36 71 1.2 0.2 0.41 3600
T71EC02X36 2.4 0.41 0.82 3600
T71EC03X36 3.2 0.55 1.1 3000
T90EC03X36 90 3.2 0.55 1.1 3600
T90EC05X36 4.8 0.75 1.5 3600
T90EC07X36 7 1.1 2.2 3600
T100EC10X36 100 9.5 1.5 3 3600
T100EC14X36 14 2.2 4 3600
T100EC19X30 19.1 3 5.5 3000
T132EC26X30 132 25.5 4 7.5 3000
T132EC35X30 35 5.5 11 3000
T132EC48X30 47.7 7.5 15 3000
T132EC59X30 58.9 9.2 18.5 3000
T132EC70X30 70 11 22 3000

High Efficient Axial Fan ECI Motor
** The rated torque is based on the motor cooling method. The detail torque please see data sheet.

Efficiency class
E-MAX motor has ultra-high efficiency both at full load and light load. The flat efficiency curve can save more energy when the motor drive the fan or pump in HVAC field.
Compare to IE4 motor efficiency class E-MAX

E-Max Commercial series

** System efficiency include the motor and drive efficiency.

E-Max Industrial series

** Efficiency is only motor efficiency.

Model number nomenclature
T  90  EC  03  V  36  C2  B14  P  T1
1   2   3    4  5   6   7    8    9  10

 
Position Character Description
1 "T" Product platform
2 "90" Frame size: IEC 90#
3 "EC" EC: permanent magnet motor
ECI: permanent magnet motor with integrated drvie
4 "03" Rated torque
5 "V" Cooling method:
G = General purposes, with fan and fan hood. IC411
V = Ventilation applications, without fan and fan hood.
6 "36" Maximum speed: 3600 rpm
7 C2 Power line connection method:
T1 = Terminal box on top
T2 = Terminal box on NDE
C1 = No terminal box, power line from housing
C2 = No terminal box, power line from NDE
8 B14 Mounting method:
B3, B14, B5, B34, B35
9 P P = Slid rail
10 T1 Voltage code:
T1: 3 phase 360-440 V
T2: 3 phase 200-240 V
S1: 1 phase 200-240 V
S2: 1 phase 115 V


VFD consideration
PMSM must drive by the VSD. The motor cannot connect to the normal AC power directly. The VSD can be the commercial drive with vector control or PM motor control mode. VSD need to be set up the correct motor parameter (see below table). The detail parameters can be find in the model data sheet.

Power choose consideration
       The power and torque in above model list is the rated power or torque when the motor has not any cooling method (IC410). If the motor cooled by the wheel or the load the motor power can be larger. The detail running range please see detail model data sheet. Below chart is a sample to decide the power at different cooling condition
.

Technology

  1. Experienced on the fan, pump, compressor and motion application with permanent magnet motor design
  2. Motor model building and simulation, performance calculation, noise optimization
  3. Motor material database: silicon steel, magnet, copper, aluminum
  4. High precision test equipment and instrument
              High Efficient Axial Fan ECI Motor


Manufacturing and quality control
  1. Automatic winding machine to get better consistency
  2. Electrical test equipment
  3. Magnetic flux checking

High Efficient Axial Fan ECI Motor
High Efficient Axial Fan ECI MotorHigh Efficient Axial Fan ECI Motor
Customer Application
High Efficient Axial Fan ECI Motor

Customers & Exhibitions
High Efficient Axial Fan ECI Motor

High Efficient Axial Fan ECI Motor  High Efficient Axial Fan ECI Motor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now