• High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression
  • High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression
  • High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression
  • High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression
  • High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression
  • High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression

High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression

Certification: ISO, ASME, API
Application: Cooler, Condenser
Principle: Principle of Vortex Tube
Style: Fin Tube
Material: Customized
Size: Customized, Scalable
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Manufacturing Standards
GB150, ASME, API661
Certificates
ISO9001,ASME API
Optional Configuration
Louver, Heating Coil, Air Circulation, Bug Screen
Packing and Shipping
Customized
Export Markets
Global
Applied Area
Metallurgy, Petrochemical, Chemical, Light Industr
Performance Guarantee
12 Months
Service Life
20 Years
Scope of Supply
Design, Manufacture,Installation Instruction
Transport Package
as Per Request
Specification
GB/NB/JB/HG
Trademark
Wintech
Origin
Shandong China
Production Capacity
500sets/Year

Product Description

High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas CompressionProject: Natural gas process in Uzbekistan

 
Applied fields Petroleum, metallurgy ,industrial, chemical, medical etc.
Bare tube Material Carton Steel, Stainless Steel, Duplex Steel
Life Span design life 15 years
Design/Manufacturing standards ASME VIII-I, API661, GB150
Certificates ISO9001, ASME, API
Lead time on the scale of order. Generally, goods can be sent out within 60 days
Packing Generally, goods are packed according to per request.
Shipping Qingdao port and Tianjin port 


Advantage:
 Wintech air cooler using seamless steel tube (Carbon steel, copper or stainless steel), the advantages of the use of the fin tube: when the heat source or the cold source for the liquid state, such as steam, water, heat conduction oil. Need to heat gas or gas cooling, the need for a greater heat exchange area. The area of the fin tube is a few times as many as 10 times the ordinary light pipe area. At this point not only increases the efficiency of the device, and greatly reduces the heat transfer cost.

1.External finned structure, can greatly improve the heat transfer area, enhanced heat transfer performance.

2.Many branch in parallel structure, flexible design heat exchange process, meet the requirements in heat flow and temperature difference under different working condition.

 

Service: 
 Technical support can be provided at anytime.During the warranty period, equipment damage caused by natural factors, we provide free maintenance, equipment damage caused by artificially we can provide technical support.
Air heat exchanger  ,radiator with fins
Air heater has several forms including electric heating, steam heating, and oil heating etc.
Air cooling machine, with the environment air as the cooling medium, is the equipment to cool or condensate the process fluid with high temperature in the tube. It is called "air cooler" for short, and is also called "air cooling heat exchanger". Air cooler can be also called as fin blower that is often used to replace the cooling medium of water-cooling shell-tube heat exchanger.
Types of air cooler:
 Sorted according to ventilation mode:
1.       Blowing-type: Tube banks lie in the exhaust side of the blower
2.       Draught fan: Tube banks lie in the inlet side of the blower
Sorted according to the installation and placing modes of the tube banks:
1.       Horizontal type:  Horizontally place the tube banks
2.       Inclined type: Inclinedly place the two tube banks with the horizontal plane in 60°dip angle
3.       Vertical type: The tube banks are vertically placed on both sides of the structure. It is often used by the driving blower of the  natural gas engine.
  High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression
High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression

High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression
High Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas CompressionHigh Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas CompressionHigh Efficiency Customized Fin Tube Bundle Forced Draft Air Cooled Heat Exchanger for Refining, Petrochemcial and Natural Gas Compression





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001, HSE
Terms of Payment
LC, T/T