• Current Transformer Tester CT PT Vt Analyzer CT PT Test Set
  • Current Transformer Tester CT PT Vt Analyzer CT PT Test Set
  • Current Transformer Tester CT PT Vt Analyzer CT PT Test Set
  • Current Transformer Tester CT PT Vt Analyzer CT PT Test Set
  • Current Transformer Tester CT PT Vt Analyzer CT PT Test Set
  • Current Transformer Tester CT PT Vt Analyzer CT PT Test Set

Current Transformer Tester CT PT Vt Analyzer CT PT Test Set

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer CT PT Vt Analyzer
Type: Transformer CT PT Vt Analyzer
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Static Load
Samples:
US$ 6800/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
GDVA-405
Display
Digital
Control
Manual Control
Weight
15kg
Power Source
AC220V
Product Name
Current Transformer Tester CT PT Vt Analyzer
Usage
Transformer Tester
Test Standards
IEC60044-1/2/5/6
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Maximum Knee Voltage
45kv
Power Supply
220V 50Hz
Current Measurement Range
0~10A
Secondary Current
1A,3A,5A
Power Output
500va
Transport Package
Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
200PCS/Month CT PT Analyzer

Product Description

Current Transformer Tester CT PT Vt Analyzer CT PT Test Set
Current Transformer Tester CT PT Vt Analyzer CT PT Test Set
Current Transformer Tester CT PT Vt Analyzer CT PT Test Set
Product Description
Current Transformer Tester CT PT Vt Analyzer CT PT Test Set
The Current Transformer Tester CT PT VT Analyzer CT PT Test Set is specially designed for testing critical parameters of current and potential transformers used in high voltage substations, transmission lines and switchyards. 

Featuring superior voltage insulation and advanced measurement capabilities, this analyzer can accurately measure turns ratios and analyze performance parameters of current transformers and potential transformers with primary voltages up to 765kV and higher.  


Key features of the transformer CT PT analyzer include:

• Measurement of CT and PT ratios up to voltage class 765kV and higher   
• Measurement of phase displacement and ratio errors with precision
• Automatic ratio and polarity testing for convenient and fast testing   
• Burden and resistance measurement for secondary windings  
• Analysis of transient performance response under abnormal conditions
• Large LCD screen for clear display of test results and parameters
• Compact, rugged design for use in substations and switchyards


The high voltage capability and precision measurements of this CT PT analyzer enable thorough testing of high voltage current and potential transformers to verify ratings, troubleshoot issues and ensure reliability. Utilities can identify potential problems in CTs and PTs before they lead to equipment downtime or safety issues.

By detecting flaws and deviations from specifications, the high voltage transformer CT PT analyzer helps power companies optimize performance, extend lifespan and improve safety of current and potential transformers used in high voltage power systems. It is a valuable asset for substation maintenance and testing teams.

Current Transformer Tester CT PT Vt Analyzer CT PT Test Set

Main Test Function

CT (protection, measurement) PT
Volt-ampere characteristic (excitation characteristic) curve Volt-ampere characteristic (excitation characteristic) curve
Automatically give the inflection point value Automatically give the inflection point value
Automatically give 5% and 10% error curves Transformation ratio measurement
Transformation ratio measurement Polarity judgment
Polarity judgment Ratio measurement
One flow test Angle difference measurement
Ratio measurement AC withstand voltage test
Angle difference measurement Secondary load test
AC withstand voltage test Secondary winding test
Secondary load test  Iron core demagnetization
Secondary winding test  
Iron core demagnetization  
 

 

Packing List for Transformer CT PT Analyzer

Name  Quantity  Description
Host machine  1  
3M mask cable  2 Test cable for power out and CT
secondary
connection
10M mask cable 1 Test cable for CT primary connection
Grounding cable 1  
Big test pliers   2 One red and one black
Test gasket  4 Two red and two black
Test pin  4 Two red and two black
Test pliers 12 Three red and nine black
Short connection cable  1 Including six connection terminals
3A fuse 3  
Power cable 1  
Accessories bag  1  
Production disk 1 Include Analysis application and user manual
User manual 2  
Inspection report 1  
Pass certificate 1  
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters