• Flooring Radiant Panel Test Apparatus
  • Flooring Radiant Panel Test Apparatus
  • Flooring Radiant Panel Test Apparatus
  • Flooring Radiant Panel Test Apparatus
  • Flooring Radiant Panel Test Apparatus
  • Flooring Radiant Panel Test Apparatus

Flooring Radiant Panel Test Apparatus

After-sales Service: All Life Technical Supports
Warranty: 12 Months
Product Name: Flooring Radiant Panel Test Apparatus
Standard: ISO 9239-1, ISO 9239-2, ASTM E 648, ASTM E 970, NF
Usage: Flooring Material Radiant Panel Test
Power: AC 220V, 50/60Hz, 20A( Customizable)
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-ISO9239
Weight
About 300kg
Instructions
Provide
Exhaust
30~85m3/Min
K-Type Thermocouples
Range, Ambient About 1500 Degree Centigrade
Utilities
Bottled Propane Gas, Air Compressor (5HP)
Transport Package
Plywood Case
Specification
1, 400mm(W)*500mm(D)*2, 200mm(H)
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
500 Sets/ Year

Product Description

Flooring Radiant Panel Test Apparatus
Flooring Radiant Panel Test Apparatus

Critical Radiant Flux is the main parameters of the fire risk for flooring materials, it reflects the burning and spreading ability of flooring material specimen under external heat radiation conditions. It is an important index of combustion classification for building products.

According to ISO9239-1,2 and GB/T 11785-2005 requirements, Flooring Radiant Panel Test Apparatus is measuring the critical radiant of combustion floor coverings, through the radiation environment of the test chamber. It is can also be used to measure the critical radiation of the cellulose insulation floor material.

Specimen is located at the down horizon of 30 degrees sloped gas radiation panel per horizon surface.

Pilot flame as ignition resource put a part edge of the specimen on the high-temperature side.

This equipment record ignition time by spark, moving time which flames horizontal pass by a specimen of length.
 

Application:

1.Building Materials

2.Rail

3.Automotive Interior

4.Other

 

Standard:

>>> ISO 9239-1: Reaction to Fire Tests for Flooring- Part 1: Determination of Burning Behavior Using a Radiant Source

>>> ISO 9239-2: Reaction to Fire Tests for Flooring- Part 2: Determination of Flame Spread at a Hat Flux Level of 25kW/m2

>>> ASTM E 648: Standard Test Method for Critical Radiant Flux of Floor- Covering System Using a Radiant Heat Energy Source

>>> ASTM E 970: Standard Test Method for Critical Radiant Flux of Exposed at Attic Flooring Insulation Using a Radiant Heat Energy Source

>>> NFP A 253: Standard Method of Test for Critical Radiant Flux of Floor Covering System Using a Radiant Heat Energy Source (National Fire Code. Vol.6)

>>> KS F ISO 9239- 1: Reaction to Fire Tests for Flooring- Part 1: Determination of Burning Behavior Using a Radiant Source

>>> KS F ISO 9239-2: Reaction to Fire Tests for Flooring- Part 2: Determination of Flame Spread at a Hat Flux Level of 25kW/m2
Flooring Radiant Panel Test Apparatus

 

Main Features:

1. All structural components are made of stainless steel, beautiful appearance and corrosion resistance.

2. Test chamber is made of the panel (calcium + silicate ) as 13±1 mm of thickness and 650 kg/m3 of nominal density.

3. Air pass dimension between the test chamber and test specimen holder is produced by (0.23±0.03) m3 at both beside of specimen fairly.

4. The calorimeter is imported from the United States, range 50kW/m2.

5. Radiant chamber had a stop of 30±1degree per horizon panel and can be resisted up to 900-degree centigrade. It also should be included in the safety-blocking function.

6. The radiation source is a porous ceramic heat radiating plate of 300mm*450mm and tilted 30 °.

7. Pilot burner should be stationed equally as 0.7mm diameter and 19/EA produced a slop of 60 degrees per centre line bottom.

8. Air velocity of exhaust stack should be attached an exhauster as 2.5±0.2 m/s.

9. It should be used a radiation pyrometer which can be monitor 250mm diameter from about 1.4 meters and has ±5 degree centigrade sod ml accessory with 480ºC to 530ºC (black body temperature) range for adjustment the surface quality of heat of radiant panel.

10. It can be measured hat flow within tolerance from radiant heat panel to 110mm to 910mm at 100mm intervals.

11. It can be adjusting the flame length of 60mm to 120mm on Pilot burner flame.

12. It can b adjust the limited temperature (900ºC) of backside panel according to air flow condition of the radiation heat panel.

13. Inlet flows control valve, precise control of propane flow.

 

Specification:

1. Steel frame chamber, Dimension:1,400mm(W)×500mm(D)×2,200mm(H)

2. Console Size: 600mm(W)×750mm(D)×1600mm(H)

3. Power: AC 220V, 50/60Hz, 20A

4. Weight: about 300kg

5. Instructions: Provide

6. Exhaust:30~85m3/min

7. Calcium silicate insulation board

8. Observation window

9. A sliding platform for loading the specimen

10. Auto moving ignition burner

11. Scale for check flame spread

12. K-type thermocouples: Range, Ambient about 1500 degree centigrade

13. The stainless steel sample holder

14. Dummy calibration panel holder for measuring heat fluxmeter

15. Pyrometer for measuring radiant panel temperature

16. Utilities: Bottled propane gas, Air compressor (5HP)

 

Send your message to this supplier

*From: