• Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester
  • Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester
  • Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester
  • Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester
  • Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester
  • Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester

Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester

After-sales Service: Lifetime Technical Support, Online Service
Warranty: 1 Year for Transformer Turns Ratio Tester
Product Name: Transformer Turns Ratio Meter
Application: Test Y, D, Z Type Transformer
Power Supply: Lithium Battery or 220V 50/60Hz Power
TTR Measurement Range: 0.8~10000
Samples:
US$ 1700/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Company Profile
Overview

Basic Info.

Model NO.
GDB-P
Function
Turn Ratio, Phase Angle, Error, Tapping Position
Hv Side Voltage Measurement Accuracy
0.05%
LV Side Voltage Measurement Accuracy
0.1%
Net Weight
8kg
Print
Build in Micro Printer
Test Standard
IEC60076
Transport Package
Plywood Case for Transformer Turns Ratio Tester
Specification
10kg
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description


Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester

The other two models

 
Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester
Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester

1. Introduction

GDB-P Transformer Turns Ratio Tester is an automatic tester that measures transformation ratio of single phase and three phase transformers, which is suitable for using in power system, transformer manufacturer and railway electrical system. It is suitable to be used for power transformer, phase shifting rectifier transformer, Scott transformer, Inverse Scott transformer.

2. Features
 
1) 5 inch TFT color LCD screen, intuitively display data and vector diagram.
2) 3 phase testing at the same time. Single power input, with internal digital combination standard sine wave test source. It generates 3 phase test power output, the test result has better equivalence.
3) It can conduct single-phase measurement and three-phase winding automatic test. Turn ratio, phase angle, error, tapping position, tapping value of AB, BC, CA three phase can be measured for once. It also can identify connecting group number automatically.
4) Accurately measure phase angle between high voltage side and low voltage side. It also can measure turns ratio and angle of "Non-integral point" transformer.
5) Testing results can be displayed by digit and hexagon vector diagram, that the connection group can be seen intuitively.
6) No need to select connection method or group. When measuring Y/△, △/Y transformer, no need to short circuit externally.
7) Connection method can be shifted automatically according to selected test content. Measure turns ratio and group for the transformer without nameplate.
8) TTR and TTR error in the position of each tapping switch can be measured quickly. Just input rated TTR once, instead of inputting over and over again, TTR error at tapping position can be calculated.
9) With functions of turns ratio measurement and voltage TTR measurement.
10) With good anti-vibration performance.
11) Standard sine wave digital source, distortion degree is less than 0.1%.
12) Small size and light weight, easy to carry.
13) Built-in high capacity chargeable lithium battery. Test can be conducted without any power supply on site, and once the battery is charged fully, it can make measurement for more than 500 times continuously.

3. Technical Index
 
1 TTR measurement range 0.8~10000
2 Fast measurement speed three-phase test can be completed within 60 seconds
3 Measurement accuracy Voltage measurement accuracy on HV side: 0.05%
Voltage measurement accuracy on LV side: 0.1%
Phase angle measurement accuracy: 0.1°
TTR measurement accuracy: 0.1% (0.8-3000); 
0.2% (3000-10000)
 
Company Profile

Factory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR TesterFactory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR TesterFactory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR TesterFactory Price Three Phase Transformer Turns Ratio Metetr with Battery TTR Tester

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters