Dp-23 Dp-58 Dp-88 Dp-812 Dp-816 High Accuracy Split Core Voltage Current Transformer

Application: Electronic, Instrument
Type: Current Transformer
Phase: Three
Samples:
US$ 18.24/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Dp-23 Dp-58 Dp-88 Dp-812 Dp-816 High Accuracy Split Core Voltage Current Transformer pictures & photos
Dp-23 Dp-58 Dp-88 Dp-812 Dp-816 High Accuracy Split Core Voltage Current Transformer
US $16.14-18.24 / Piece
Min. Order: 1 Piece
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
DP-23 DP-58 DP-88 DP-812 DP-816
Operation Condition
Indoor
Usage
Protection, Measurement
Winding Form
Small Fixed Type
Insulating Medium
Common Insulating Materials
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Antistop
Split Core Current Transformer
Rated Test Voltage
3kv AC (1min)
Safe Factor
Fs 5
Secondary Current
5A / 1A
Rated Insulation Voltage
AC 0.72kv
Working Temperature
-10~+50
Rated Frequency
50/60Hz
Continuous Overload
1.2in
Size
111*90 (20*32mm)
Warranty
2years
Transport Package
Export Standard Carton Box
Specification
CE
Trademark
Winston/OEM
Origin
China
HS Code
8504311000
Production Capacity
100000 PCS/Year

Packaging & Delivery

Package Size
15.00cm * 13.00cm * 5.00cm
Package Gross Weight
0.500kg

Product Description

DP Series High Accuracy Split Core Current Transformer   DP-23

Description

The DP Series current transformer has been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or busbar circuit.The connection of conventional CTs usually requires the interruption of the primary side current to pass cables or busbar through the transformer core to connect such cables to the primary terminals.

Feature
Two installation methods: Panel / Busbar.
Wide inner window,allowing clamping of big cables or busbar
Wide range of sizes to accommodate all the existing installation
Primary current from 5A to 5000A
Dp-23 Dp-58 Dp-88 Dp-812 Dp-816 High Accuracy Split Core Voltage Current Transformer

Specifications
Rated frequency 50Hz/60Hz
Rated test voltage 3kv AC (1min)
Rated short-time thermal current (lth) 60in
Rated dynamic current (ldyn) 2.5lth
Rated voltage (Um) 0.72kv AC
Continuous overload (ld) 1.2In
Operating temperature -10°C~50°C
Housing self-extinguishing class VO
Safety factor FS 5
Secondary current 5A/1A 

Technical data and dimension

Type Ration (A) Rated power (VA)
Class: 0.5 Class: 1.0
DP-23 100/5 - 1.5
DP-23 150/5 - 1.5
DP-23 200/5 - 1.5
DP-23 250/5 - 1.5
DP-23 300/5 1.5 2.5
DP-23 400/5 2.5 3.75
Dp-23 Dp-58 Dp-88 Dp-812 Dp-816 High Accuracy Split Core Voltage Current Transformer

 
   
Product detail

Dp-23 Dp-58 Dp-88 Dp-812 Dp-816 High Accuracy Split Core Voltage Current Transformer
Dp-23 Dp-58 Dp-88 Dp-812 Dp-816 High Accuracy Split Core Voltage Current TransformerDp-23 Dp-58 Dp-88 Dp-812 Dp-816 High Accuracy Split Core Voltage Current Transformer
Our Services
1. Prompt reply: Any inquiry or questions would be replied within 24 hours.
2. Quality Product: Manufacture company, each of the products is tested and calibrated.
3. Hospitality: Offer smiling service and your visiting is highly welcomed
4. Fast delivery: delivery time is within 3-7 days usually, other occasion depends on the order qty.

Trade Information
Trade Terms FOB,CIF,CFR,EXW
Payment terms T/T,L/C,Western union,Paypal,Escrow,MoneyGram
Payment conditions 30% deposit in advance,70% balance before shipping.
Delivery time 3-7working days after deposit,2-4 working days for inventory
Packing Neutral carton,Wooden case for large size
Shipping By sea,by air and by express delivery
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Dp-23 Dp-58 Dp-88 Dp-812 Dp-816 High Accuracy Split Core Voltage Current Transformer pictures & photos
Dp-23 Dp-58 Dp-88 Dp-812 Dp-816 High Accuracy Split Core Voltage Current Transformer
US $16.14-18.24 / Piece
Min. Order: 1 Piece
Diamond Member Since 2011

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory
Number of Employees
17
Year of Establishment
2010-05-05