• Deep Well Submersible Pump Inverter IP20
  • Deep Well Submersible Pump Inverter IP20
  • Deep Well Submersible Pump Inverter IP20
  • Deep Well Submersible Pump Inverter IP20
  • Deep Well Submersible Pump Inverter IP20
  • Deep Well Submersible Pump Inverter IP20

Deep Well Submersible Pump Inverter IP20

Application: Three Phase Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Rating: 5.0/5
Guangdong, China
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (31)

Basic Info.

Model NO.
B6031D
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Constant Torque Universal Type
Brand
Bedford
Control Method
Constant Presssue Control,Sleep Mode
Protection
Oc,Ou,UV,Dry Protection,Phase Failure Proteciton
Power Range
0.75~350kw
IP Grade
20
Color
Blue
Transport Package
CTN or Pallet
Specification
220V, 380V
Trademark
BEDFORD
Origin
Guangzhou, China
Production Capacity
5000pieces/Month

Product Description

Deep Well Submersible Pump Inverter
Deep Well Submersible Pump Inverter IP20
B6031 series products is specifically designed for deep well submersible pump, Some models controller can be set the parameter selection to control single-phase or three-phase pumps.
This manual provides you the main features, parameter setting and operation methods of B6031 series. Before operating please read this manual and understand the contents of this manual to ensure proper use of B6031 series.

Features
Single-phase, three-phase selection function: Some models controllers can be 
  chosen to control single-phase or three-phase motor.
Power orestartRunning automatically when power on.
Sleep functionSleep down when have no water consumption, to earn a better 
  energy saving.
Manual/auto switch-over function: Switching over realize constant speed/constant pressure water supply function.
Various of water supply fault alarm function: High-pressure, low-pressure,
  transducer, water shortage error etc.
Many fault protection function: Over-current, over-voltage, phase-failure, 
  over-load etc.

Selection guide

Table2.3.1 B6031 list
Model No. Rated Input Voltage (V) Input Current (A) Maximum Output Current (A) Motor Power (kW)
1Φ 3Φ
B6031D(B2)-2001 1AC: 220V
-15%~+15%
8.2 7.0 0.37 0.75
B6031D(B2)-2002 14.2 11.0 0.75 1.5
B6031D(B2)-2003 23.0 15.0 1.5 2.2
B6031B2-4001 3AC: 380V
-15%~+15%
5.0 3.7 / 0.75
B6031B2-4002 5.8 5.0 / 1.5
B6031B2-4003 8.0 7.0 / 2.2
B6031B2-4005 12.0 11.0 / 4.0
B6031B2-4007 18.0 16.0 / 5.5
B6031B2-4010 21.0 20.0 / 7.5

INSTRUCTIONS OF PARAMETERS GROUP
Function Code Name Setting Range Factory Setting Description
Br00 Group Application Function
b00.00 Debugging password 0~65535 00000 Default is 00000
b00.01 Constant Speed Operating Frequency 000.0~600.00 50.00Hz Constant speed operating frequency value
b00.02 Pressure Setting Value 0.0~100.0bar 3.0bar Set according to the actual requirements of user
b00.03 Phase Selection 0~1 1 Single phase or three phase motor selection
0three phase    1single phase
b0.04 There Phase Motor Rotating Direction 0~1 0 0: forward   1: reverse 
b00.05 Restart After Power-on 0~1 1 0: invalid        1: valid
b00.06 Frequency Instructions Selection 0~6 5 0: constant speed
5constant pressure water supply
b00.07 Maximum Transducer Setting Range 0.0~100.0bar 16.0bar E.g. If the rated max. range of transducer is 10 bar, b00.07 should be set to10.0
b00.08 High Water Pressure Alarm Value 0.0~100.0bar 10.0bar When the pressure is higher than this preset value, the controller alarmshalts and displays "HP"; when the pressure is lower than this preset value, breakdown recover and running
b00.09 Low Water PressurAlarm Value 0.0~100.0bar 0.0bar When the pressure is lower than this preset value for a Low Pressure Running Time, the controller alarmshalts and displays "LP"; restart automatically from breakdown after 10 minutes' downtime.
b00.10 Low Pressure Running Time 00~300s 20s
b00.11 Water Shortage Protection Factor 0~100.0% 30 When the pump controller neither can pump the water after running a period of time (b00.13(s)+b00.20(s)+b00.21(s)), nor reported "A033" (digital display) fault, please turn up the b00.11 data, until it could reported "A033" fault. When reporting "A033" fault delay b00.12 can automatically restart, If b00.12=0, it could not restart after the water shortage fault.
b00.12 Latency Time to Restart After Water Shortage Protection 0~30000min 0
b00.13 Check the Running Time
in State of Water Shortage
01~60s 20
b00.14 Restore Defaults 0~2 0 0: No action 
1: Set to default 
2: Clear error records
b00.15 AI1 Lower Limit -10.00~10.00V 1.00V  Currency type4~20mA, setting b00.15=1.00
Voltage type: 0.5~4.5v, setting b00.15=0.50;
 Lower limit use to transducer Zero Setting
b00.16 AI1 Higher Limit -10.00~10.00V 5.00V  Currency type4~20mA, setting b00.16=5.00,
Voltage type: 0.5~4.5v, setting b00.16=4.50;
 Higher limit use to accordant display and transducer pressure;
 When display smaller than gauge, increase higher limit;
 When display greater than gauge, decrease higher limit
b00.17 Proportional Gain (KP) 0.00~100.00 3.50 Determining the strength of PID regulation, KP is bigger, regulation is stronger, but fluctuate easier too. 
b00.18 Wake-up Pressure Bias 0.0~b0.02
(0.0~20.0bar)
0.3bar During sleeping the wake-up pressure bias, e.g. the setting value (L)=3.0Bar, Bias (b00.18)=0.3bar, practical pressure (P)<L-0.3=2.7bar, the pump will restart again.
b00.19 Sleeping Bias 0.0~1.0bar 0.1bar The pressure fluctuation which allows sleeping.
b00.20 Acceleration Time 0.1~3600.0s 1s The setting time from zero to max. Frequency
b00.21 Deceleration Time 0.1~3600.0s 1s The setting time from max. Frequency to zero
b00.22 Maximum Output Frequency b00.23~600.00Hz 60.00Hz Determine the Acc./Dec. rate
b00.23 Up limit of Output Frequency b00.24~b00.22 (Maximum Frequency) 60.00Hz Maximum running frequency
b00.24 Lower Limit of Output Frequency 0.00~b00.23 20.00Hz The minimum running frequency of pump
b00.25 Latest Fault Type     E000~E022,LP,HP,A033
b00.26 Motor Rated Voltage 0~460V 220V  
b00.27 Motor Rated Current 0.0~2000.0A Model Set B6031D(B2)-2001 set to 7.0A;
B6031D(B2)-2002 set to 11.0A;
B6031D(B2)-2003 set to 15.0A;
B6031B2-4001 set to 2.5A;
B6031B2-4002 set to 5.0A;
B6031B2-4003 set to 7.0A;
B6031B2-4005 set to 11.0A;
B6031B2-4007 set to 16.0A;
B6031B2-4010 set to 20.0A
b00.28 Single Phase Motor Current Calibration 
Coefficients
115~150% 130% When display current greater than actual current, decrease the coefficients;
When display current smaller than actual current, increase the coefficients
b00.29 Freeze-proofing 0~1 0 Used in cold areas  
0: invalid      1: valid
b00.30 Minimum Freeze-proofing Frequency 1.00~30.00Hz
(1.00~b00.24)
5.00Hz Be valid when b00.29 was set to 1, whenever sleeps, running with the setting frequency in case of freezing.
b00.31 Password of Group br01 0~65535 00000 Don't try to enter or will cause abnormal operation and damages.
Attention: Bold function code won't restore the default setting even if resetting.

Deep Well Submersible Pump Inverter IP20
 
Deep Well Submersible Pump Inverter IP20
Deep Well Submersible Pump Inverter IP20



 