RSQ06
GB/3810.9-2016, ISO10545-9: 1994, GB/T3298-2008
This equipment is specially used to test the thermal shock resistance of ceramic tile, it uses Immersion method to test, it also can be used to test glass, silicate products, fireproof materials. Electric lifting device equipped.
Furnace max work temperature | 300ºC |
Temperature accuracy | < ±5ºC |
Working chamber size | 300×300×300mm, 600×300×600mm |
Cold furnace temperature rise time | 60min(RT-300ºC) |
Cold material into furnace temperature recovery time | 5 5mins (300ºC,7kg) |
Water trough temperature control range | 15-50ºC |
Control accuracy | ±2ºC |
Water temperature unevenness | ±2ºC |
Hot material into water temperature rise in 5mins |
±4ºC(material temperature 300ºC,7kg) |
Heat furnace max consumption | 6kw |
Water heater max power |
4kw |
Compressor power | 2.2kw |
Timer range | 0~120mins |
Working power supply | AC 380V±10%, 50HZ±10% |
Main machine 1set, sample holder 1pc, aluminum plate (optional for Non-immersion test), aluminum particile (optional for Non-immersion test)