• Holtop Air Handling Unit Industrial Commercial Ahu with Heat Recovery Core
  • Holtop Air Handling Unit Industrial Commercial Ahu with Heat Recovery Core
  • Holtop Air Handling Unit Industrial Commercial Ahu with Heat Recovery Core
  • Holtop Air Handling Unit Industrial Commercial Ahu with Heat Recovery Core
  • Holtop Air Handling Unit Industrial Commercial Ahu with Heat Recovery Core
  • Holtop Air Handling Unit Industrial Commercial Ahu with Heat Recovery Core

Holtop Air Handling Unit Industrial Commercial Ahu with Heat Recovery Core

Certification: CE, ISO9001
Application: Industrial
Control Mode: Standard Controller
Usage: Dust Removal, Smoke Removal, Humidification, Air Conditioning Handling System
Model: Heat Recovery Section Optional
Airflow: 1000~10000m3/H
Samples:
US$ 2000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
HJK series
Heating and Cooling Section
Optional
Control System
Optional
Panel Thickness
25/40/50mm
Panel Type
Double Skin
Heat Recovery Device
Heat Recovery Core or Wheel
Cooling Method
Cooling Coil
Transport Package
Wooden Cases
Specification
ISO9001: 2008, ISO14001, ISO18001
Trademark
Holtop or OEM
Origin
Beijing, China
HS Code
8415821000
Production Capacity
800 Sets/Year

Product Description

Ceiling Air Handling Unit Loft Mounted

Holtop Air Handling Unit Industrial Commercial Ahu with Heat Recovery Core


Specifications

1. AHU, Air flow 2799-51849m3/h
2. Energy Recovery section: Available, all systems-plate heat exchanger, rotary wheel
3. All size available


Working principle

1. Both supply fan and exhaust fan are built inside to bring in fresh air and exhaust out the stale indoor air as well, thus to keep indoor spaces in natural comfort;

2. Built-in heat exchanger(rotary heat exchanger or plate heat exchanger)transfers energy contained in the outgoing indoor air to the coming fresh air, thus fresh air is precoolid or preheated;

3. Various functional sections such as filter section, cooing/heating section, humidifying section etc. Can be combined together to meet different air treatment requirements.
Holtop Air Handling Unit Industrial Commercial Ahu with Heat Recovery Core
HOUSING CONSTRUCTION FEATURES

1. Frost resisting cold bridge design
Double-skin panel sandwiched with high density PU foam, thermal conductivity below 0.01999W/m Degree, insuring high performance between -40Degree and +70Degree.

2. High mechanical strength
Galvanized sheet inner skin, color steel sheet outer skin, strong steel framework, pressure endurance up to
2000PA, suitable for large air application.

3. High air impermeability
Double inlaid sealing to join the frameworks and panels tight, minimizing air leakage.

4. Flexible combination
Designed with 102mm modulus, frameworks and panels are flexible to change according to design requirements.
No. Part Name Material Description
1 Unit panel external plate material is colorful steel sheet t0.4mm, specialized for air conditioning elegant apprearance, dignity,high corrosion resistance
inner plate material is galvanized steel sheet t0.5mm adopt spangle-free
2 Panel heat preservation high pressure foamed polyurethane t 50mm good insulation performance, high strength, foaming ratio 40Kg/m³
3 Other heat preservation polyethylene foaming good insulation performance
4 Unit frame t 1.0mm  colorful steel sheet frame corrosion resistance, long product life,  high strength
5 Copper tube of cooling coil Ø12.7mm copper tube,  wall thickness 0.41mm phosphorized seamless copper tube, good heat-transfer
 
6 Cooling coil fin Ø12.7mm copper tube, adopt aluminium foil t0.15mm aluminium foil surfact dealt with acrylic resin
7 Cooling coil header/piping seamless steel pipe, taper pipe welded HVAC special pressureizated seamless steel pipe
8 Drain pan stainless steel,  ( cold-roll steel sheets spray treatment  t1.5mm, optional standard type) corrosion resistance,long product life,clean
9 Rotary heat exchanger sensible, 0.05mm heat exchang aluminum foil high efficient heat exchange, clean-self
10 Primary filter G4 synthetic plate type ,PVC frame non-woven
11 Secondary filter F7 synthetic bag type ,PVC frame non-woven
12 Supply fan/Exaust fan Belt drive multi-blade anteverted centrifugal fan high-quality bearings, good performance,low noise
13 Damper Rubber damper good elastictiy,good vibration reducing performance,low the noise
14 Braid connection  PVC coating B1 flame-proof type
15 Unit base  C type steel surface spraying treatment, high strength, high corrosion resistance
16 Package form  wood pallet, wrapping film  
Holtop Air Handling Unit Industrial Commercial Ahu with Heat Recovery CoreHoltop Air Handling Unit Industrial Commercial Ahu with Heat Recovery CoreHoltop Air Handling Unit Industrial Commercial Ahu with Heat Recovery CoreHoltop Air Handling Unit Industrial Commercial Ahu with Heat Recovery Core

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
7.39 Million USD
Plant Area
38000 square meters