AC to DC Solar System High Power Better Charge

Certification: CE
Condition: New
With LED: With LED
Flexibility: Portable
Application: Car Charger
Accessories: Charger Adapter
Customization:
Manufacturer/Factory & Trading Company
Diamond Member Since 2015

Suppliers with verified business licenses

Zhejiang, China
Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
Customization from Samples
The supplier provides sample based customization services
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (22)

Basic Info.

Transport Package
Honeycomb Box or Wooden Box
Trademark
Bangzhao and OEM
Origin
Zhejiang
HS Code
8504403090
Production Capacity
99999

Product Description

Functional details

1.    Hot plug
Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system.
2.    Advanced current sharing technology
Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than ±0.5A.
3.    Control of input limited power
Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 320 Vac ~ 530 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode.
4.   Control of output constant power
When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module.
Note:
The module uses two operating modes with output voltage ranges of 50V to 600V and 50 to 750V.  Boot without a demand     voltage.The default operation is in the low-voltage segment mode; if the monitored demand voltage is higher than 600V, the module will automatically switch to the high-voltage segment mode. When the demand voltage is lower than 550V At the same time, it automatically cuts back to the low pressure section mode.
The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage.

5.    Temperature limited power
Under 55°C ambient temperature, the module can output full power of 20kW;
Over 55°C ambient temperature, the module shall be used by derating with the power Linearly .
Under 65°C ambient temperature, the allowable output power of the module is 10kW.
Under 75°C ambient temperature, the output power of the module is reduced to 0.
6.    Regulation of output current limiting point
The module has the function of stepless current limiting. The current limiting point within the scope of 0~33.3A(High voltage)/0A~50A(low voltage) is adjustable through the external monitoring module. When the output voltage is within 50Vdc ~ 750Vdc, the current limiting accuracy of the module is ±0.3A.
7.    Regulation of output voltage
The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc.
8.    Fan control
The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module.
9.    Protection of input overvoltage/ voltage shortage
When the input voltage is less than 260 Vac or more than 530 Vac, the protection indicator light is on and the module stops working, without output.
when the module is in Single-phase communication mode, the input voltage is less than 160 Vac or more than 300 Vac, the protection indicator light is on and the module stops working, without output Meanwhile, this condition will be transmitted to the monitoring module. The function can be recovered automatically.
10.  Output overvoltage protection
The overvoltage protection point is 260Vdc ~770Vdc (±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection.
11.  Over-temperature protection
The environmental over-temperature protection point is 80°C. When the DC panel has a temperature over 100°C, the module will stop working; when the DC panel has a temperature below 90°C, the module will automatically work again.
12.  Protection of internal bus fault
When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on.
13.  Short circuit protection
In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
14.  Interruption of background communication
After module communication interruption, the protection indicator light will flash and the module will be subject to shutdown protection. When the communication is recovered, the protection indicator light recovers to normal state and the module works again.
15.  Protection against fan fault
In case of module communication interruption over 8S, the module will be subject to shutdown protection, without voltage output and the protection indicator light will flash. After fault removal, the module will work automatically again.
16.  Monitoring performance
The charging module is equipped with CAN bus. It can also be converted to RS232 via the protocol converter, and the RS485 protocol communicates with the external monitoring module.
Refer to Table 1-2 for the list of the monitoring information.
Command / Signal Issued by the Monitoring Module of the Charger System Charging Module Information Collected by the Monitoring Module of the Charger System
Module start-up/ shutdown
Setting of function of output current slow rise
Regulation of the current limiting point of charging module
 Regulation of the output voltage of charging module
 
Input voltage, output voltage and output current
Current limiting point and temperature of charging module
DC output overvoltage point
DC switch state
Fault alarm and protection alarm
Temperature limited power and input limited power
AC power failure
Current unbalance

Technical Parameters

Table 1-3   Technical Parameters of Charging Module
Category Name Parameter
Environmental conditions Operation temperature -40°C ~ +75°C, derating is require when the temperature is above 55°C.
Storage temperature -40°C ~ +70°C
Relative humidity ≤95%RH, without condensation
Cooling mode Forced air cooling
Altitude 2,000 m a.s.l., derating is require when the altitude is above 2,000 m a.s.l.
Atmospheric pressure 79 kPa ~ 106 kPa
AC input Input system Three phases + PE
Voltage range 260 Vac ~ 530 Vac
The maximum static voltage borne under no operation 600 Vac
Rated voltage 400 Vac
Maximum current 32A
Grid frequency 45 Hz~ 65 Hz
Rated frequency 50Hz/60Hz
DC output Voltage range 50 Vdc ~ 750Vdc
Current range 0 ~ 33.3A (high voltage)/ 0~50A(low voltage)
Rated current 26A@750V (required for setting of current limiting point,750V is 26.67A)
Steady voltage precision <±0.5%
Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)
Load regulation rate ≤±0.5%
Grid regulation rate ≤±0.1% (testing range is 320V ~ 530V)
Startup overshoot ≤±3%
Peak-to-peak value noise ≤1% (150~750V, 0~20MHz)
Power factor and THD Power factor ≥0.95   Full-load output power of @20%~50%
≥0.98   Full-load output power of @50%~100%
≥0.99  Full-load output power, input nominal voltage and frequency of @100%
THD ≤5%  Full-load output power of  @50%~100%
Efficiency Under Rated input voltage 95.2%,@750V,50%~100%
EMC Emission ClassA , Meet the requiremnt of  NB/T 33001-1-2010,NB/T 33008-1-2013  
Immunity C lassA , Meet the requiremnt of  NB/T 33001-1-2010,NB/T 33008-1-2013  
Other Instant impulse current upon startup <45A
Current sharing In case of load of 10%~100%, the module current sharing error ≤ rated output current of ±5%.
Noise 65dB(1m away,
Startup duration (select the startup mode through the monitoring module) Normal startup mode: the time delay from AC power-on to module output is ≤ 8s.
Output delayed startup: The startup duration can be set through the monitoring module, with default output startup duration of 3~8s.
Earthing resistance Earthing resistance ≤ 0.1Ω, bearable current ≥ 25A
Surge protection Meets IEEE C62 41-1991 Class B3 rating, 6kV/3kA (1.2/50μs impulse voltage and 8/20μs inrush current mixed wave)
Insulation  resistance The insulation resistance of DC part and AC part to housing and the AC part to the DC part shall be ≥ 10MΩ.
Insulation strength AC input terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA;
AC input terminal to DC output terminal 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady-state leakage current is less than
1mA;
DC output terminal to the housing 3535V DC voltage 20S clock, no breakdown, no arcing phenomenon, steady state leakage current is less than 1mA;
  ROHS R5
Mechanical parameters Size 84Mm (H) ×226mm (W) ×395mm (D)
Weight ≤11kg

Packaging & Shipping
Why Whoose our product
Contact information


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now