• 72.5kv 50Hz/60Hz Outdoor Inductive Combined Current /Voltage Transformer
  • 72.5kv 50Hz/60Hz Outdoor Inductive Combined Current /Voltage Transformer

72.5kv 50Hz/60Hz Outdoor Inductive Combined Current /Voltage Transformer

Application: Instrument
Type: Combined Transformer
Phase: Single
Operation Condition: Outdoor
Usage: Protection, Measurement
Winding Form: Multilayer Honeycomb Type
Samples:
US$ 15000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
VU
Insulating Medium
Insulating Oil
Installation
Extension Type
Specification
66KV/132KV
Trademark
HEMG
Origin
China
Production Capacity
50000

Product Description

72.5kv 50Hz/60Hz Outdoor Inductive Combined Current /Voltage Transformer
 
ITEM DESCRIPTION UNIT OFFERED
1 Highest voltage for equipment kV 72.5 kV
2 System frecuency Hz 60
3 Rated power-frequency withstand voltage  kVms 140
4 Rated lighting impulse withstand voltage kV peak 350
5 Standard   IEC
Voltage Unit
7 Rated primary voltage kV 69/√3
8 Rated secondary voltage kV 115/√3 
9 Accuracy class for measurement Class 0.5
10 Accuracy class for proteccion kV 3P
11 Simultaneous burden for measuring winding  VA 30VA
Current Unit
12 Rated primary current A 600
13 Rated secondary current A 5
14 Short time thermal current (Max) KA  20/ 3s
15 Dynamic current kA peak 80
16 Accuracy class for measurement Class core 1:  0.2
17 Accuracy class for proteccion Class core2:  5P/20
18 Intrument security factor FS   5
19 Rated burden VA 30VA
 
ITEM DESCRIPTION UNIT OFFERED
1 Highest voltage for equipment kV 72.5 kV
2 System frecuency Hz 60
3 Rated power-frequency withstand voltage  kVms 140
4 Rated lighting impulse withstand voltage kV peak 350
5 Standard   IEC
Voltage Unit
7 Rated primary voltage kV 69/√3
8 Rated secondary voltage kV 115/√3 
9 Accuracy class for measurement Class 0.5
10 Accuracy class for proteccion kV 3P
11 Simultaneous burden for measuring winding  VA 30VA
Current Unit
12 Rated primary current A 600
13 Rated secondary current A 5
14 Short time thermal current (Max) KA  20/ 3s
15 Dynamic current kA peak 80
16 Accuracy class for measurement Class core 1:  0.2
17 Accuracy class for proteccion Class core2:  5P/20
18 Intrument security factor FS   5
19 Rated burden VA 30VA

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now