Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Arc Chamber
Installation: Fixed
Structure: MCCB
Samples:
US$ 12.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Shanghai, China
Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (24)

Basic Info.

Model NO.
DAM3-160
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC, RoHS
Base
BMC Unflaming Material
Terminal
with Terminal Box
Transport Package
Carton
Specification
25, 32, 40, 50, 70, 80, 100, 125, 160A
Trademark
CDADA, OEM, ODM
Origin
Shanghai, China
HS Code
8536200000
Production Capacity
40000PCS/Month

Product Description

Overview

630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture


The rated insulation voltage of the DAM3-160 molded case circuit breaker is 1000V. These circuit breakers are suitable for power distribution circuits with an alternating current of 50-60Hz, a rated operating voltage up to 400V, and rated operating current from 25A to 160A. The circuit breaker is important in distributing power and protecting the circuit and power equipment from overloading, short circuits, and undervoltage failure damage. They can also be used in electric motors for infrequent starting and overload protection as well as protection against short circuiting and undervoltage conditions.

Compared with the DAM1 series, the DAM3 series have the characteristics of smaller volume, higher breaking capacity, and more energy saving.

Electrical parameters of DAM3-160 molded case circuit breaker
Rated current of frame size Inm [A]   160
Rated current [A] 25-160
Number of poles  2/ 3 / 4
Rated operating voltage (AC)50-60HZ [V] 400/690
DC [V] 250/1000
Rated impulse withstand voltage Uimp [KV] 8
Rated insulation voltage Ui [V] 750
Test voltage at industrial frequency for 1 min [V] 3000
Rated ultimate short-circuit breaking capacity Icu [KA] A B C N
(AC)50-60HZ 220/230V [KA] 18 28 36 50
(AC)50-60HZ 400/415V [KA] 12 16 25 36
(AC)50-60HZ 690V [KA] 4 6 8 12
(DC)250V-2 Poles in series 12 16 22 30
(DC)500V-2 Poles in series 6 8 10 12
(DC)750V-4 Poles in series 10 15 18 22
(DC)1000V-4 Poles in series 8 12 15 18
Rated service short-circuit breaking capacity, Ics [KA]        
(AC)50-60HZ 220/230V [% Icu] 60% 60% 60% 50%
(AC)50-60HZ 400/415V [% Icu] 60% 60% 60% 50%
(AC)50-60HZ 690V [% Icu] 60% 60% 60% 50%
category of utilization (EN 60947-2) A
Isolation condition Bitmap
Reference standard IEC/EN 60947-2/GB 14048.2
Interchangeability -
Versions Fixed Bitmap
Plug-in Bitmap
Draw-out -

Physical parameters of DAM3-160 molded case circuit breaker
Endurance Total cycles 10000
Electrical endurance 1500
Mechanical endurance 8500
Basic dimensjons-fixed version 3/4 Poies W[mm] 27(1P) / 54(2P) / 76 / 101
3/4 Poies H[mm] 59 62.5
H1[mm] 78.5 82
3/4 Poies L[mm] 120

Introduction

The DAM3-160 molded case circuit breaker automatically cuts off the current when the current exceeds the release setting. The molded case refers to the plastic insulator used as the frame of the device to insulate the conductor and the metal grounding component.

630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture
630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture
630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture
630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture
630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture
630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture
630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture
630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture

630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture

630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture
630AMP Small Size MCCB Top DIN Rail Type Power Circuit Breaker Manufacture
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now