Model NO.
AC440V-500KW
Voltage
400V,415V,440V,480V
Power
500kw
Frequency
50Hz, 60Hz
Power Factor
1
Control
Local and Remote
Communication
RS485, RS232
Resistor
Metal Alloy
Warranty
12 Months
Transport Package
Wooden Box
Specification
ISO
Trademark
Triumph Load
Origin
China
HS Code
90309300
Production Capacity
500units

Product Description

AC Generator load bank

Product Introduction:
Resistance/inductance/capacity Automatic load bank
Automatic AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model. It is of high power density, no red hot phenomenon and automatic protection function overheated. It can't be overheated and broken when the fans stop working. The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client's request, and provide scientific test measures for high-power AC equipment.

440V 500kw Load Bank to Test Generator440V 500kw Load Bank to Test Generator440V 500kw Load Bank to Test Generator


Main functions
1. Users can set adjustable discharge power according to capability parameter and test request.
2. Discharge time can be set: Load can be closed time out.
3. Voltage and current value can be displayed with digital meter.
4. The complete machine is of resistance breaking automatic overheated adopts new power consumption component.
5. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.
6. It 's of machine combination function.