Shanghai, China
Business Type: Trading Company
For this serie,it includes:
12V,15V,20V,24V,30V,36V,42V,48V,54V outputs.For more details,please check the following Spec:
MODEL | HLG-40H-12 | HLG-40H-15 | HLG-40H-20 | HLG-40H-24 | HLG-40H-30 | HLG-40H-36 | HLG-40H-42 | HLG-40H-48 | HLG-40H-54 | |
OUTPUT | DC VOLTAGE | 12V | 15V | 20V | 24V | 30V | 36V | 42V | 48V | 54V |
CONSTANT CURRENT REGION Note.4 | 7.2 ~12V | 9 ~ 15V | 12 ~ 20V | 14.4 ~ 24V | 18 ~ 30V | 21.6 ~ 36V | 25.2 ~ 42V | 28.8 ~ 48V | 32.4 ~ 54V | |
RATED CURRENT | 3.33A | 2.67A | 2A | 1.67A | 1.34A | 1.12A | 0.96A | 0.84A | 0.75A | |
RATED POWER | 39.96W | 40.05W | 40W | 40.08W | 40.2W | 40.32W | 40.32W | 40.32W | 40.5W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 300mVp-p | 300mVp-p | |
VOLTAGE ADJ. RANGE | Adjustable for A-Type only (via built-in potentiometer) | |||||||||
10.8 ~ 13.5V | 13.5 ~ 17V | 17 ~ 22V | 22 ~ 27V | 27 ~ 33V | 33 ~ 40V | 40 ~ 46V | 44 ~ 53V | 49 ~ 58V | ||
CURRENT ADJ. RANGE | Adjustable for A-Type only (via built-in potentiometer) | |||||||||
2 ~ 3.33A | 1.6 ~ 2.67A | 1.2 ~ 2A | 1 ~ 1.67A | 0.8 ~ 1.34A | 0.67 ~ 1.12A | 0.58 ~ 0.96A | 0.5 ~ 0.84A | 0.45 ~ 0.75A | ||
VOLTAGE TOLERANCE Note.3 | ±2.5% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.5% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME Note.6 | 500ms,80ms/115VAC 500ms,80ms/230VAC | |||||||||
HOLD UP TIME (Typ.) | 16ms / 115VAC, 230VAC | |||||||||
INPUT | VOLTAGE RANGE Note.5 | 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section) | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
POWER FACTOR (Typ.) | PF 0.98/115VAC, PF 0.95/230VAC, PF 0.92/277VAC @ full load >= >= >= (Please refer to " " )POWER FACTOR (PF) CHARACTERISTIC section | |||||||||
TOTAL HARMONIC DISTORTION | THD< 20% (@ load 60% / 115VAC,230VAC; @ load 75% / 277VAC) >= >= (Please refer to "TOTAL HARMONIC DISTORTION (THD) section)" | |||||||||
EFFICIENCY (Typ.) | 86.5% | 86.5% | 88% | 88% | 88.5% | 88.5% | 88.5% | 89.5% | 89.5% | |
AC CURRENT (Typ.) | 0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC | |||||||||
INRUSH CURRENT(Typ.) | COLD START 50A(t =210 s measured at 50% I ) at 230VAC; width peak Per NEMA 410 μ | |||||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC | |||||||||
LEAKAGE CURRENT | <0.75mA / 277VAC | |||||||||
PROTECTION | OVER CURRENT | 95 ~ 108% | ||||||||
Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 15 ~ 21V | 18 ~ 24V | 23 ~ 30V | 28 ~ 35V | 35 ~ 43V | 41 ~ 49V | 48 ~ 58V | 54 ~ 65V | 59 ~ 68V | |
Shut down o/p voltage, re-power on to recover | ||||||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||||||||
ENVIRONMENT | WORKING TEMP. | Tcase= -40 ~ +80ºC (Please refer to "OUTPUT LOAD vs TEMPERATURE" section) | ||||||||
MAX. CASE TEMP. | Tcase= +80ºC | |||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80ºC, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ± ºC ºC0.03%/ (0 ~ 60 ) | |||||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||||
SAFETY & EMC | SAFETY STANDARDS Note.8 | optional models for J61347-1, J61347-2-13 ; design refer to UL60950-1, TUV EN60950-1, EN60335-1 UL8750(type"HL"), CSA C22.2 No. 250.0-08 (except for 48V, 54V), TUV EN61347-1, EN61347-2-13 independent, IP65 or IP67 approved ; | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH | |||||||||
EMC EMISSION Note.8 | Compliance to EN55015, EN61000-3-2 Class C (@ load>=60%) ; EN61000-3-3 | |||||||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV) | |||||||||
OTHERS | MTBF | 1131.9K hrs min. Telcordia SR-332 (Bellcore) ; 336.5K hrs min. MIL-HDBK-217F (25ºC) | ||||||||
DIMENSION | 171*61.5*36.8mm (L*W*H) | |||||||||
PACKING | 0.73Kg; 20pcs/15.6Kg/0.9CUFT | |||||||||
NOTE | 1 All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 ºC ol ambient temperature 2 Ripple & noise are measured at 20MHz ol bandwidth by using a 12" twisted pair-wire terminated with a 0 1ul & 47ul parallel capacitor 3 Tolerance : includes set up tolerance, line regulation and load regulation 4 Please reler to "DRIVING METHODS OF LED MODULE" 5 De rating may be needed under low input voltages Please -reler to "STATIC CHARACTERISTIC" sections lor details 6 Length ol set up time is measured at lirst cold start Turning ON!OFF the driver may lead to increase ol the set up time 7 The driver is considered as a component that will be operated in combination with linal equipment Since EMC perlormance will be allected by the complete installation, the linal equipment manulacturers must re-qualily EMC Directive on the complete installation again 8 The model certilied lor CCC(GB19510 14, GB19510 1, GB17743 and GB17625 1) is an optional mode l Please contact MEAN WELL lor details 9 To lullill requirements ol the latest ErP regulation lor lighting lixtures, this LED driver can only be used behind a switch without permanently connected to the mains 10 This series meets the typical lile expectancy ol >62,000 hours ol operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 ºC or less 11 Please reler to the warranty statement on MEAN WELL's website at http:!!www meanwell com |