• 36kv High Voltage Sf6 Gas Load Break Switch
  • 36kv High Voltage Sf6 Gas Load Break Switch
  • 36kv High Voltage Sf6 Gas Load Break Switch
  • 36kv High Voltage Sf6 Gas Load Break Switch
  • 36kv High Voltage Sf6 Gas Load Break Switch
  • 36kv High Voltage Sf6 Gas Load Break Switch

36kv High Voltage Sf6 Gas Load Break Switch

Type: High-voltage
Structure: Double-column Disconnector
Installation: Indoor High-voltage
Operation: Electric
Grounding Mode: Grounding
Movement Mode: Plug-in Type
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Fujian, China
to see all verified strength labels (22)

Basic Info.

Model NO.
GSC-36
Number of Poles
Three Pole
Grounding
Double Ground
Series
Three
Run
Vertical Rotation
Switching Mode
Double-Throw Type
Common Model
PR
Structure of Operating
Electric
Certification
ISO, IS9001, ISO9001, ISO9002, ISO2000
Brand
Greno
Transport Package
Carton
Specification
phase distance 210mm, 230mm, 275mm
Trademark
GRENO
Origin
Xiamen
Production Capacity
5000sets/Year

Product Description

Warmly wecome to Send us any enquiries anytime"
36kv High Voltage Sf6 Gas Load Break Switch36kv High Voltage Sf6 Gas Load Break Switch
36kv High Voltage Sf6 Gas Load Break Switch


We focus on every detail 
36kv High Voltage Sf6 Gas Load Break Switch

GSC-36,
Completely under IEC international standard and GB standard.
Arc-extinguishing and insulation by SF6 gas.
Especially suitable for secondary distribution.
36kv High Voltage Sf6 Gas Load Break Switch
36kv High Voltage Sf6 Gas Load Break Switch


++++ Main technical specifications
Item NO. Name Unit Technical parameters
Load break switch panel
1 Rated Voltage Un kV 12 24 36
2 Rated Frequency Hz 50 50 50
3 Rated Current A 630 630 630
4 Rated Load Breaking Current A 630 630 630
5 Rated Short Time Withstand Current(rms) kA 20 20 20
6 Rated Short Time Duration s 3 3 3
7 Rated Peak Withstand Current  kA 50 50 50
8 Rated Closed Switch - Off Current A 630 630 630
9 Rated Cable Charging Breaking Current A 10 10 10
10 Rated Active Load Breaking Current A 630 630 630
13 Earthing Switch 2s Short Time Withstand Current  kA 20 20 20
14 Rated Short-Circuit Current Making Times  times 2 2 2
15 Rated Current Breaking Times times 10 10 10
16 Mechanical Endurance  Load Break Switch times 3000 3000 3000
Earthing Switch times 2000 2000 2000
17 SF6 gas anual leakage rate≤   /year 0.10% 0.10% 0.10%
18 Rated Insulation Level Unit Technical parameters
1min Power Frequency withstand voltage(rms) On isolating distance kV 48 60 110
Phase to Phase  kV 42 50 85
Phase to Earth kV 42 50 85
Lightning impulse withstand voltage(peak) On isolating distance kV 85 145 215
Phase to Phase  kV 75 125 185
Phase to Earth kV 183 184 185
Note: For short circuit breaking and peak current is based on Fuse plus combination.
Our Services
12 months warranty
Type test, technical and marketing support.   
Warmly welcome customized design.
After-sales service ..
 
    

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
54
Year of Establishment
2010-08-11