11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable

Application: Construction, Underground, Power Station
Voltage: Low and Medium Voltage Cable
Current: AC Cable
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 0/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
YJV32 YJLV32
Certification
ISO
Product Name
11kv Power Cable
Standard
IEC60502
Rate Voltage
11kv 15kv 33kv
Conductor
Copper or Aluminum
Insuation
XLPE
Sheathed
PVC
Armour
Steel Wire Armour Steel Tape Armour Aluminum Wire
Size
185mm2
Certificate
TUV Psb
Transport Package
Standard Export Drum
Specification
IEC60502
Trademark
RNE DA
Origin
Hebei, China
HS Code
85444921
Production Capacity
500km/Month

Product Description


 
33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Power Cable

1 Application:
 It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable. Power cables for power networks, underground, outdoors and in cable ducting.

Standard: BS6622, BS EN/IEC 60228,IEC60502.2
Conductor: Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Conductor screen: Semi-conducting material
Insulation: XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen: Semi-conducting material
Metallic Screen: Individual and overall copper tape screen to BS6622
Filler: PET (Polyethylene Terephthalate) fibres
Separator: Binding tape
Bedding: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Armouring:

Single Core: Aluminium Wire Armoured (AWA)
MultiCore: Steel Wire Armoured (SWA)
Sheath: PVC (Polyvinyl Chloride) Type TM1 to BS7655
Colour: Red or Black

2. Using features :Medium Voltage Power Cable Underground 11kv 15kv 33kv XLPE Power Cable

1. Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
2. No. of core: Single core or three cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250ºC.
4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit.
7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
9. Minimum Bending Radius:Single core - Fixed: 15 x overall diameter;3 core - Fixed: 12 x overall diameter
(Single core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)
Note:The single core armoured cables are used for D.C. system only. If used for A.C. system, the magnetic isolation should be applied on the steel armor wires of non-magnetical materials should be used.
11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable



11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable11kv 15kv 33kv PVC/XLPE/PE Insulated PVC Sheatd Aluminum Copper Under Armoured Medium Voltage Mv Power Urd Cable


 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018