220V 50Hz Single Phase Online UPS with Ce Approve

Phase: Single Phase
Type: On-line
Protection: Short Circuit
Application: Communication
Classification: Lighting/Power
Standby Time: Standard Machine
Samples:
US$ 100/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Queen Star Plus Series 6-10k
Standby UPS
Sine Wave Output UPS
Output Capacity
Large Type
Equipment Mode
Decentralized
Brand
Upsen
Battery Type
Lead-Acid Maintenance-Free Battery
Transfer Time
Zero Conversion
Business Type
Manufacturer, OEM/ODM
Transport Package
Cartons & Wooden Pallet
Specification
CE & ISO Certificate
Trademark
UPSEN
Origin
China
HS Code
8504402000
Production Capacity
50, 000PCS/Month

Product Description

220V 50HZ  single phase online ups with CE approve


Product Advantages:                                                                                
1: Can be with 100% unbalance load
2: Energy saving and Environment Friendly
3: Active input power factor correction(PFC)
4: Pure sine wave output, true on-line double conversion design.
5: More optimized structure layout, makes the UPS size smaller.       
6: LCD Display with Advanced Monitoring for Easy UPS Management 

Main Features
1>Double conversion online technology.
2>Equipped with maintenance bypass switch.
3>Sealed lead acid, maintenance free battery.
4>ups power supply has the self test while start.
5>Protection against all type of power problems.
6>Humanization bypass output can be adjustable.    
7>Fully meet saltus of  the load  from 0 to 100%.
8>Advanced constant voltage charging technology.
9>Wide input voltage design, the remarkable grid adaptability 
10>Human friendly large LCD, with plenty operation information.
11>Support sensitive loads like Air Conditioner, Laser Printer etc.
12>Latest Tri-level inverter control tech, whole UPS high efficiency ≥94%.
13>auto restart after utility power restore when ups shutdown due to battery low. 
14>True on-line double conversion technology with advanced microprocessor control.  
 
Queen Star Plus Series 6K - 10K Technical Specification
Index Q6K Plus Q6KL Plus Q10K Plus Q10KL Plus  Comments
Input
Input voltage 
Rated voltage 220VAC  
Phase Single phase with ground  
Turn on 
voltage range
(120±5~274±5)VAC  
Bypass
voltage range
(60±5~300±5)VAC Could be adjusted 
by software.
Bypass low
 loss
60VAC~220VAC(default 60VAC)
Bypass low 
comeback
Low loss +5VAC
Bypass high 
loss
220VAC~300VAC(default 300VAC)
Bypass high 
comeback
High loss -5VAC
Line low loss
/comeback
(120±5) VAC /(140±5) VAC load≤50%
(150±5) VAC /(165±5) VAC 50%
(160±5) VAC /(175±5) VAC 80%
Line high 
loss/comeback
(274±5)VAC/(260±5)VAC  
Input frequency
Rated frequency 50Hz  
Frequency low loss (40~49) ±0.2Hz(default:46Hz) Could be adjusted 
by software.
Frequency low 
comeback
Frequency low loss +0.5Hz
Frequency high 
loss
(51~60)±0.2Hz(default:54Hz)
Frequency high 
comeback
Frequency high loss -0.5Hz
Input power factor
It power
 factornpu
> 0.99 Q6K Plus & Q6KL Plus:
 220VAC, full R load
Q10K Plus & Q10KL Plus:
full R load
Generator  Support generator input Generator rating
≥2*UPS rating
Input current
Rated current  25A 27A 41A 43A  
Input THDI 10%  
Output protection
Rating protection 32A Breaker 50A Breaker  
Output power  
VA/watt 6000/4800 10000/8000  
Rated voltage 220VAC Sine wave
Voltage range 200/208/220/230/240VAC Q6K Plus & Q6KL Plus: 
Could be adjusted by 
software. 10% derating 
for 208VAC/200VAC.
Voltage regulation ±1%  
Voltage distortion ≤6% Full RCD load
≤2% Full R load
DC offset ≤200mV  
Transient response ≤9% R load 0%~100%~0%
≤6% R load 
20%~100%~20%
Transient recovery ≤60ms voltage recovery to 90% Full RCD load
Bypass output 
before turn-on
YES  
Crest ration 3:1  
Output frequency range
Normal mode 1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz)
 
Battery mode (50+0.1) Hz  
Slew rate 1 Hz/Sec  
Efficiency
Normal  mode > 93%  
Battery mode > 91%  
Overload
Normal mode/
battery mode
Overload warning only 105%±5%≤load
1min,then transfer to bypass and alarm. 105%±5%<load≤
125%±5%
30S,then transfer to bypass and alarm. 125%±5%<load≤
135%±5%
100mS, then transfer to bypass and alarm. load>135%±5%
Automatically 
retransfer
YES  
Short protection
Normal/
battery mode
YES  
Transfer time
Normal to 
battery mode
0mS 0mS  
Battery to 
normal mode
0mS 0mS  
Normal to 
bypass mode
<4mS 0mS Q6K Plus & Q6KL Plus: 
0mS  (option)with load
Bypass to 
normal mode
<4mS 0mS
Battery and charger
Battery
Rated voltage 192VDC  
Type/Rating Sunshine 7AH/12V   Sunshine 9AH/12V    
Battery quantity 16 PCS   16 PCS    
Backup time > 14min    >8min   Half load
Protection
Low alarm voltage/
comeback voltage
(180.8V±4V)/ (188.8V±4V)  
Shutdown voltage/
comeback voltage
(176V±4V)/ (184V±4V) (176V±4V)/ (184V±4V) (176V±4V)/ (184V±4V) (176V±4V)/ (184V±4V) Load < 1000W
(152V±4V)/ (160V±4V) (160V±4V)/ (168V±4V) (152V±4V)/ (160V±4V) (160V±4V)/ (168V±4V) Load>= 1000W
DC protection
Overcharge 
protection/ 
comeback voltage
(249.6V±4V) / (216V±4V)  
Leakage current < 500uA  
Over discharge
 protection
14.5h Could be set by software
Battery test
Battery weak YES  
Battery fault YES  
Charger
Output voltage (219.2±3)VDC  
Charge time 7 hours to 90% capacity        
Charge current 1A 5.5A 1A 5.5A  
Interface
Alarm silence YES  
DC power 
turn-on
YES  
Automatically 
retransfer
YES  
Audio alarm
Battery mode Beep/4s  
Battery low/
charger fault
Beep/1s  
UPS fault Continue beep  
Overload Beep/1s  
Bypass mode Beep/2Min  
L/N inverse Beep/2Min  
Communication
RS232 interface YES  
Intelligent slot YES  
Monitor software Appending with UPS  
Cooling
Force air cooling
Display
LCD/LED 
displays UPS 
status
         
Environment
Work 
temperature
0ºC~40ºC  
Altitude <1000m  
Audible noise ≤55dB ≤60dB  
Storage 
temperature
-15ºC~45ºC  
Work humidity 20%~95%  
Standard
EMS
ESD IEC61000-4-2 Level4
RS IEC61000-4-3 Level3
EFT IEC61000-4-4 Level4
Surge IEC61000-4-5 Level4
EMI
Conducted EN55022 Class B
Radiated EN55022 Class B
Safety
Safety GB4943-2001/IEC62040-1  
Transportation
Drop test GB-T4857-18  
Vibration test B-WR1-129(GB-T14715-93)  
Machinery features
Size
Outline dimension and net weight
L*W*H(mm) 533*260*560 425*190*328 533*260*560 533*260*501  
Net weight
(Kg)
55kg 12.2kg 62kg 21kg  
Optional functions
60Hz Optional Set by software
Converter mode Optional Set by software
ECO Optional Available and set by software
EPO Optional  
LCD display Optional  

220V 50Hz Single Phase Online UPS with Ce Approve

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now