• 200mm Cable Medium Voltage Current Transformer
  • 200mm Cable Medium Voltage Current Transformer
  • 200mm Cable Medium Voltage Current Transformer
  • 200mm Cable Medium Voltage Current Transformer
  • 200mm Cable Medium Voltage Current Transformer
  • 200mm Cable Medium Voltage Current Transformer

200mm Cable Medium Voltage Current Transformer

Application: Electronic, Instrument, Position Sensor, Audio, Lighting
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection
Winding Form: Single Layer & Tightly Wound Type
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LXZ-200
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Types
Current Transformer
Ratio
200/5A
Class
10p10
Weight
15.5kg
Dimension
200X320X70
Working Temperature
-15 to +40
Standards
IEC60044-1, IEC61869-2
Material
Resin
Diameter
200mm
Burden
5va
Transport Package
Standard Export Box
Specification
LXZ-200, 10P10
Trademark
GFUVE
Origin
China
Production Capacity
10000PCS/Month

Product Description

LXZ-ø200 200mm cable protective Medium voltage 10KV current transformer
200mm Cable Medium Voltage Current Transformer
Product description
The indoor LXZ-ø200 200mm cable MV current transformer of epoxy resin cast insulated and totally-enclosed structure is intended for zero-sequence over current protection of voltage system, high-voltage three phase AC generator and motor in the line of AC 50/60Hz.
It is applicable to air insulated switchgear
It conforms to GB 1208 and IEC60044-1 standards
Service conditions
Installation site: indoor
Ambient temperature: -15~+40
Altitude: does not exceed 1000m
Humidity: the average value of the relative humidity meadured for a period of 24 h does not exceed 95%
Contamination severity: class II
No severe shake or bump in the installation site
The ambient air is not significantly polluted by dust, smoke, corrosive gases, vapours or salt
Structure overview
This post busbar type totally-enclosed current transformer is epoxy resin cast insulated
The primary outlet terminal identification is P1 and the secondary is S1, S2
Technical data
Rated voltage 0.5kv , max voltage 0.72KV, rated frequency 50/60 Hz, the power-frequency withstand voltage for secondary winding 3KV/1min
Other parameters are specified in accordance with GB 1208 and IEC 60044-1, IEC61869-2

Technical Data
Technical parameters
 
Standards IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006
Rated primary current 75-100, 150, 200, 250, 300-600A
Rated load 10VA, 15VA, 20VA, 25VA, 30VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Accuracy class and combination 10P10, 10P5
Mechanical parameters
 
Dimensions (W×D×H) (mm) φ200xφ320x70
Weight (kg) 15.5
Operating conditions
 
Operating temperature -15°C to +40°C
Daily average temp <+40°C
Storage temperature -40°C to +70°C
Altitude <1000 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.