Medical Equioment Patient Monitor Hospital Use Yj-F5

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient Monitor
Certification: CE, ISO13485
Group: Adult; Pediatric; Neonate
Name: Patient Monitor
Model: Yj-F5
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
YJ-F5
Display
12.1 Inch High-Brightness TFT LED
Printer
Built-in High-Speed 50mm Thermal Printer
Battery
Rechargeable Lithium Battery 14.8V/2200mAh
Power Supply
AC100~240V, 50/60Hz, Power≤60W
Dimension
310mm*290mm*150mm
Weight
3.4kg(Excluding Accessories)
Input Device
- Touch Screen (Option) - Knob (Standard) - Keypad
Transport Package
Wooden Packing
Trademark
forermed
Origin
China
Production Capacity
5000PCS/Month

Product Description

Patient Monitor YJ-F5
Medical Equioment Patient Monitor Hospital Use Yj-F5

The YJ-F5 patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.

An optional Nellcor /Masimo SpO2 module enable accurate measurement in NICU.




Features
Body
12.1 inch high-brightness TFT LED
Support display maximum 8 waveforms
Support 6 channel ECG waveform display simultaneously
Optional touch screen

Stroage
Support storage of 168 hours trend table and graph review
100 minutes waveform review
500 groups NIBP review
100 hours of parameter alarm events review and associated parameters

Printer
Built-in high-speed 50mm thermal printer
(Brand: SEIKO, Japan)

Central System
Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
Alarm
Three-level acousto-optic alarm
Sensor-off alarm
Paper out alarm
Support alarm review
Support alarm pause

Operating System
Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface.

NIBP self-test mode: including overpressure test, static pressure test and air leakage test.

13 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection

Drug calculation and titration table
Support multi-language display
Support online software upgrading by net

 
 Performance Specifications
Dimension and Weight
- Dimension: 310mm*290mm*150mm
- Weight: 3.4kg(excluding accessories)

Power Supply
- Voltage: AC100~240V, 50/60HZ, Power≤60W

Display
- 12.1" color TFT LED
- Resolution: 800*600 pixels

Battery (Pluggable)
- Type: Rechargeable lithium battery 14.8V/2200mAh
- Charge Cycle: ≥500 times
- Working time: 2 hours (optional larger battery for 4-5 hours)

Recorder (Option)
- Method: Thermal printer
- Paper width: 50 mm (1.97 in)
- Printing speed: 25/ 50 mm/s
- Trace: Max. 2 tracks
- Recording way: Real-time Recording, Review Printing, Alarm Recording

Alarm
- Level: Low, medium and high
- Indication: Auditory and visual
- Alarm volume adjustable
- Alarm pause time: 1min, 2min
- Parameter alarm type: Latch/ Unlatch

Input Device
- Touch screen (option)
- Knob (Standard)
- Keypad input (Standard)

System Output & Extensible Interface
- Ethernet Network: 1 standard RJ45 socket

Operating Environment
- Temperature: 5 ~ 40 ºC
- Humidity: 15% ~ 80% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa

Transportation and Storage Environment
- Temperature: -20~50 ºC
- Humidity: 10%~90% (non-condensing)
- Atmosphere pressure: 86 KPa ~ 110 KPa

Safety
- IEC60601-1 Approved, CE marking according to MDD93/42/EEC
- With reference to RoHS Directive 2011/65/EU recasting

Trend & Reviewing
- Trend: 168 hours
- NIBP measurement reviewing: 500 groups
- Waveform review: 100 minutes
- Alarm event: 100hours of parameter alarms events and associated parameter

SpO2 (Analog Technic)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy: ±2% (70% ~ 100%)
Unspecified (0 ~ 69%)

Pulse Rate
- Measuring and Alarm Range: 20~300bpm
- Accuracy: ±3%
- Resolution: 1bpm

Nellcor-SpO2 (Option)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
- Accuracy:
70% ~ 100%, ±2 % (adult)
70% ~ 100%, ±3 % (Neonate)
70% ~ 100%, ±2 % (Low Perfusion)
0% ~ 69%, unspecified

Pulse Rate
- Measurement range: 20 ~ 300 bpm
- Resolution: 1bpm
- Accuracy:
±3 bpm (20 ~ 250 bpm)
Unspecified (251~300 bpm)

IBP (Option)
- Max Channel: 2
- Measurement way: Thermal resistance way
- Press Sensor:
Sensitivity 5 uV/V/mmHg, ±2%
Impedance 300 to 3000Ω
- Resolution: 1 mmHg
- Unit: mmKg, kPa, cmH2O
- Transducer sites:
Arterial Pressure (ART)
Pulmonary Arterial (PA)
Left Arterial (LAP)
Right Arterial (RAP)
Central Venous Pressure (CVP)
Intracranial Pressure (ICP)
P1/ P2
- Measuring and alarm range:
ART 0 ~ +350mmHg
PA -10 ~ +120 mmHg
CVP/ RAP/ LAP/ ICP -10 ~ +40 mmHg
P1/ P2 -50 ~ +350mmHg
- Accuracy:
Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer)
±4mmHg or ±4%, whichever is greater (inclusive of transducer)
Dynamic: ±4mmHg or ±4%, whichever is greater



* Specifications subject to change without prior notice
ECG
- Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
- Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2),
- Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s
- ECG signal range: ±6 mV
- Accuracy: ±1bpm/ ±1%, whichever is greater
- Resolution: 1 bpm
- Leakage Current < 10 μA
- Input impedance: > 5.0Mohm
- CMRR:
Diagnostic Mode >90 dB;
Monitor Mode>100dB
Surgery Mode>100dB
- Baseline Recovery:
≤ 5s after defibrillation (Monitor or Surgery mode)
- Bandwidth: Surgery 1 ~ 20Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
- Against electrosurgical interference and defibrillation
- Indication of Electrode Separation: Every electrode (exclusive of RL)

Heart Rate
- Measure range:
Adult: 0bpm; 15 ~ 300 bpm
Neo/Ped: 0bpm; 15 ~ 350 bpm
- Resolution: 1 bpm
- Accuracy: ± 1% or ± 1bpm, whichever is greater

ST Measurement
- Range: -2.0 ~ +2.0 mV
- Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
- Other range: unspecified

Respiration
- Method: Impedance between RA-LL, RA-LA
- Gain: ×0.25, ×0.50, ×1, ×2,
- Respiration Rate: 0bpm, 0 ~ 150 BrPM
- Sweep speed: 6.25 mm/s, 12.5 mm/s, 25mm/s
- Resolution: 1 BrPM
- Accuracy: ±2 bpm or ±2%, whichever is greater
- Apnea Alarm: 10 ~ 40 s

NIBP
- Method: Oscillometric
- Measure mode: Manual, Auto, STAT
- Measure Interval in AUTO Mode 1~480 min
- STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
- Measure and Alarm Range:
Adult: SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215mmHg
MEAN: 20 ~ 235 mmHg
Pediatric: SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150mmHg
MEAN: 20 ~ 165 mmHg
Neonate: SYS: 40 ~ 135 mmHg
DIA: 10 ~ 100mmHg
MEAN: 20 ~ 110 mmHg
- Static pressure accuracy: ±3mmHg
- Resolution: 1mmHg
- Accuracy:
Maximum Mean error ±5mmHg
Maximum Standard deviation ≤8mmHg
- Over pressure Protection: Dual protection via software & hardware

Temperature
- Technique: Thermistor probe (2.25K)
- Channel: Dual-channel, provide T1; T2; ΔT
- Measuring and Alarm Range:
0.0 ºC~ 50 ºC (32ºF~ 122ºF)
- Unit: Celsius (ºC), Fahrenheit ( ºF)
- Resolution: 0.1ºCor 1ºF
- Accuracy: ±0.1ºC(exclusive probe)

Masimo SpO2 (Option)
- - Measurement Range: 0 ~ 100 %
- - Resolution: 1 %
- Accuracy:
70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
70% ~ 100%, ±3 % (neonate, non-motion conditions)
70% ~ 100%, ±3 % (motion conditions)
0% ~ 69% unspecified

Pulse Rate
- Measurement range: 25 ~ 240 bpm
- Resolution: 1bpm
- Accuracy: ±3 bpm (non-motion condition)

EtCO2 (Mainstream/ Sidestream) (Option)
- Measure method: Non-dispersive infrared (NDIR)
- Measure Range: 0 ~19.7% (0 ~ 150 mmHg) 0 ~ 20 kPa
- Resolution: 0.1 mmHg
- CO2 Accuracy:
0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 25ºC)
- Respiratory Rate: Range: 3 ~150 BrPM
Accuracy: ±1 bpm

EtCO2 (Micro-stream) (Option)
- Measure method: Non-dispersive infrared (NDIR)
- Measure Range: 0 ~19.7% (0 ~150 mmHg) 0 ~ 20 kPa
- Sample Rate: 50 mL/min ±10mL/min
- Resolution:
0.1 mmHg (0 ~ 50 mmHg)
0.25 mmHg (50 ~ 114 mmHg)
- CO2 Accuracy:
0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 35ºC)
- Respiratory Rate: Range: 3 ~120 BrPM
Accuracy: ±1 bpm

  
 Medical Equioment Patient Monitor Hospital Use Yj-F5

Packing & Delivery
Medical Equioment Patient Monitor Hospital Use Yj-F5Medical Equioment Patient Monitor Hospital Use Yj-F5
Our Company 
Medical Equioment Patient Monitor Hospital Use Yj-F5Medical Equioment Patient Monitor Hospital Use Yj-F5
Certificate
Medical Equioment Patient Monitor Hospital Use Yj-F5
Our Customer

Medical Equioment Patient Monitor Hospital Use Yj-F5



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now