• 15kv/27kv/38kv Air Insulated Load Break Switch for Switchgear Panel
  • 15kv/27kv/38kv Air Insulated Load Break Switch for Switchgear Panel
  • 15kv/27kv/38kv Air Insulated Load Break Switch for Switchgear Panel
  • 15kv/27kv/38kv Air Insulated Load Break Switch for Switchgear Panel

15kv/27kv/38kv Air Insulated Load Break Switch for Switchgear Panel

Type: High-voltage
Structure: Three-column Disconnector
Installation: Indoor High-voltage
Operation: Manual
Grounding Mode: Grounding
Certification: ISO9001
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
ALBS
Transport Package
Wooden
Specification
15KV/27KV/38KV, 50HZ/60HZ,
Trademark
HEMG
Origin
China
Production Capacity
10000

Product Description

15kv/27kv/38kv Air Insulated Load Break Switch for Switchgear Panel
15kv/27kv/38kv Air Insulated Load Break Switch for Switchgear Panel
15kv/27kv/38kv Air Insulated Load Break Switch for Switchgear Panel
Rated voltage kV 12 15 24 36
Maximum service voltage kV 15 17.5 25.8 40.5
Withstand voltage to earth and between poles kV 42 38 50 70
Withstand voltage across the isolating distance kV 48 50 60 80
Impulse withstand voltage to earth and between poles kV 85 95 125 170
Impluse withstand voltage across the isolating distance kV 95 110 145 195
Rated current A 400 630 800 400 630 800 400 630 800 400 630
Breaking capacity for active circuits(cosФ0.7) A 400 630 800 400 630 800 400 630 800 400 630
Breaking capacity for no-load transformers A 16 18 16 16
Breaking capacity for no-load line and cables A 25 25 25 16
Short-time current kA 20 20 20 12.5
sec. 2s 2s 1s 1s
Making capacity kA 50 50 40 25


 

Rated voltage

kV

12

15

24

36

Maximum service voltage

kV

15

17.5

25.8

40.5

Withstand voltage to earth and between poles

kV

42

38

50

70

Withstand voltage across the isolating distance

kV

48

50

60

80

Impulse withstand voltage to earth and between poles

kV

85

95

125

170

Impluse withstand voltage across the isolating distance

kV

95

110

145

195

Rated current

A

400 630 800

400 630 800

400 630 800

400 630

Breaking capacity for active circuits(cosФ0.7)

A

400 630 800

400 630 800

400 630 800

400 630

Breaking capacity for no-load transformers

A

16

18

16

16

Breaking capacity for no-load line and cables

A

25

25

25

16

Short-time current

kA

20

20

20

12.5

sec.

2s

2s

1s

1s

Making capacity

kA

50

50

40

25

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now